Fixed-type solid-state / static relay (SSR) with red LED - 2-wire connection - for railways applications - WAGO (859 series) - single-pole / single-phase / 1-pole (1P) - control voltage 16-30Vdc (24Vdc nom.) - Rated voltage 9Vdc-60Vdc output - Rated current 0.1A (continuous) - with CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - equivalent to 859794

Specifications

  • Primary brand: WAGO
  • Functions: Fixed-type solid-state / static relay (SSR)
  • Design: red LED|2-wire connection|for railways applications
  • Poles: single-pole / single-phase / 1-pole (1P)
  • Frequency: 1.5kHz switching frequency
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 0.1A (continuous)
  • Rated Voltage (DC): 9Vdc-60Vdc output
  • Connection type: CAGE CLAMP connections
  • Control Voltage (DC): 16-30Vdc (24Vdc nom.)
  • Mounting mode: DIN-35 rail
  • Response time: (switching ON) 20μs / 0.00002s|(switching OFF) 120μs / 0.00012s
  • Dimensions: H91mm x W6mm x D56mm|6mm width
  • Material: Polyamide (PA) 66
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+70°C
  • Humidity: 5-95% relative humidity (RH; non-condensing)
  • ETIM code: EC001504
  • Customs Tariff Number: 85365005000
  • GTIN code: 4066966278989
  • eClass code: 27-26-15-03
  • Order code / Manufacturer SKU: 859-794
  • Manufacturer product status: Commercialized
  • Equivalent to: 859794
  • EAN code: 4055143606325
  • Compliant with standard(s): Safety and protection|- Overvoltage category -- II|EN 50121-3-2|EN 61000-6-2|EN 61000-6-3|EN 61010-2-201|EN 61373|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for hazardous areas|- CCC - CNEX - CNCA-C23-01 - certificate 2021312304000982 (Ex ec IIC T4 Gc)|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate WAGO22UKEX007X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - ANSI/ISA 12.12.01 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)|material group I|V-0 flammability rating
  • Location of origin: China
  • Degree of pollution: 2
  • Application type: Railways applications
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Fixed-type solid-state / static relay (SSR) - WAGO

Commercial data

  • Country of origin: CN
  • Customs tariff number: 85365005000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-26-15-03
  • eCl@ss 9.0: 27-26-15-03
  • ETIM 8.0: EC001504
  • ETIM 9.0: EC001504
  • GTIN: 4066966278989
  • Packaging type: Box
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 10 pcs

Connection data

  • Connection technology: CAGE CLAMP®
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Fine-stranded conductor; with insulated ferrule: 0.08 … 1.5 mm² / 28 … 16 AWG
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 5 … 6 mm / 0.2 … 0.24 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1|75980-60-8|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): 97e20fec-7ef8-4308-9df4-b9beadf1ef91
  • SCIP notification number (Belgium): afaadc22-038e-4c5d-ac39-69df25e85c26
  • SCIP notification number (Bulgaria): 93632ac1-b492-4946-9ed7-377e0daaed60
  • SCIP notification number (Czech Republic): b9cd1975-f211-470e-b780-095c63e5f498
  • SCIP notification number (Denmark): dee75a1a-c78d-4336-b2de-81d6bff7d37a
  • SCIP notification number (Finland): f2bcdbd1-947a-4580-b997-80bd91b96611
  • SCIP notification number (France): efa2c40b-aac0-4647-8b02-79ce02e41cee
  • SCIP notification number (Germany): cc674ec4-4da2-402f-872f-414caffff011
  • SCIP notification number (Hungary): ba812f41-53db-45a6-b453-93d6ef534a9b
  • SCIP notification number (Italy): e7f6eb14-bc4e-46df-b8d3-7fbebba411b7
  • SCIP notification number (Netherlands): 81e30e1d-6dcd-47c8-a3c3-d049af7b1761
  • SCIP notification number (Poland): 02b6ce32-a5c5-4957-be86-6b44c3b6f522
  • SCIP notification number (Romania): 15bbf093-9f9b-4fb4-be0c-e91eb4f3f17f
  • SCIP notification number (Sweden): 9a68c8aa-c768-4c87-a1ea-e685293e288d

Environmental requirements

  • Ambient temperature (operation at UN): -40 … +70 °C
  • Ambient temperature (storage): -40 … +70 °C
  • Operating altitude (max.): 2000m
  • Processing temperature: -25 … +50 °C
  • Relative humidity: 5 … 95 % (no condensation permissible)
  • Temperature range of connection cable: ≥ (Tambient + 20 K)

Material data

Mechanical data

  • Mounting position: horizontal (standing/lying); vertical
  • Mounting type: DIN-35 rail

Notes

  • Note: Optocouplers and solid state relays are designed for use in signal processing networks that are not supplied directly by the low-voltage power supply network.

Physical data

  • Depth from upper-edge of DIN-rail: 56 mm / 2.205 inches
  • Height: 91 mm / 3.583 inches
  • Width: 6 mm / 0.236 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 2.5 kVrms
  • Insulation type (adjacent devices): Reinforced insulation (safe isolation)
  • Insulation type (between adjacent devices of the same type): Reinforced insulation (safe isolation)
  • Insulation type (control/load circuit): Basic insulation
  • Insulation type (to adjacent devices of different types): Basic insulation
  • Overvoltage category: II
  • Pollution degree: 2
  • Protection type: IP20; in connected state or when using 859-525 end plate
  • Rated voltage: 300V

Standards and specifications

  • Standards/specifications: EN 61010-2-201|EN 61000-6-2|EN 61000-6-3|EN 50121-3-2|EN 61373|UL 508

Technical data

  • Control circuit - Input voltage range (high level): 16 … 30 VDC
  • Control circuit - Input voltage range (low level): 0 … 5 VDC
  • Control circuit - Nominal input current at UN: 5 mA
  • Control circuit - Nominal input voltage UN: 24 VDC
  • Load circuit - Circuit type: 2-wire connection
  • Load circuit - Leakage current at rated voltage: ≤ 25 µA
  • Load circuit - Limiting continuous current: 0.1 A
  • Load circuit - Output voltage range: 9 … 60 VDC
  • Load circuit - Switching frequency: ≤ 1.5 kHz
  • Load circuit - Turn-off time: ≤ 120 µs
  • Load circuit - Turn-on time: ≤ 20 µs
  • Load circuit - Voltage drop: ≤ 2 VDC
  • Signaling - Status indicator: Red LED