Fixed-type relay module with red LED - for railways applications - WAGO (859 series) - single-pole / 1-pole (1P) - control voltage 28.8-67.2Vdc (48Vdc nom.; 0.6...1.4 x Uc) - 1C/O / SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 5A (continuous) / 3A (250Vac; AC-15) / 2A (24Vdc; DC-13) - with CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - material Silver-Tin (AgSnO) contacts - equivalent to 859397

Specifications

  • Primary brand: WAGO
  • Functions: Fixed-type relay module
  • Design: red LED|for railways applications|Electromechanical design|10V / 10mA / 24V / 1mA recommended minimum switching load
  • Poles: single-pole / 1-pole (1P)
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 5A (continuous)|3A (250Vac; AC-15)|2A (24Vdc; DC-13)
  • Rated operating voltage (Ue): 300V
  • Rated voltage (AC): 250Vac max. (switching voltage)
  • Rated impulse voltage (Uimp): 4kV
  • Connection type: CAGE CLAMP connections
  • Control Voltage (DC): 28.8-67.2Vdc (48Vdc nom.; 0.6...1.4 x Uc)
  • Mounting mode: DIN-35 rail
  • Response time: (OFF=>ON / contacts closing) 15ms / 0.015s|(ON=>OFF / contacts opening) 25ms / 0.025s
  • Contacts type: 1C/O / SPDT (Single Pole Double Throw) contact
  • Dimensions: H91mm x W6mm x D56mm|6mm width
  • Material: Silver-Tin (AgSnO) contacts|Polyamide (PA) 66 housing
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+70°C
  • Humidity: 5-95% relative humidity (RH; non-condensing)
  • Electrical durability (with load): 50 000operations
  • Mechanical durability (at no load): 5 000 000operations
  • GTIN code: 4055143604468
  • eClass code: 27-37-16-01
  • Customs Tariff Number: 85364900990
  • ETIM code: EC001437
  • Order code / Manufacturer SKU: 859-397
  • Manufacturer product status: Commercialized
  • Equivalent to: 859397
  • EAN code: 4055143604468
  • Compliant with standard(s): Safety and protection|- Overvoltage category -- III|DNV|EN 50121-3-2|EN 61010-2-201|EN 61373|EN 61810-1|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03078|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03081|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- DNV - DNV Germany GmbH - DNV-CG-0339 / Aug.2021 - certificate TAA00001D1|- PRS - Polski Rejestr Statkow - certificate TE/1098/880590/23|RoHS compliant with exemption (7(a) / 7(c)-I)|material group I|V-0 flammability rating
  • Location of origin: Germany
  • Degree of pollution: 2
  • Application type: Railways applications
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Fixed-type relay module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85364900990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-37-16-01
  • eCl@ss 9.0: 27-37-16-01
  • ETIM 8.0: EC001437
  • ETIM 9.0: EC001437
  • GTIN: 4055143604468
  • Packaging type: box
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 10 pcs

Connection data

  • Connection technology: CAGE CLAMP®
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Fine-stranded conductor; with insulated ferrule: 0.08 … 1.5 mm² / 28 … 16 AWG
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 5 … 6 mm / 0.2 … 0.24 inches

Environmental Product Compliance

  • CAS-No.: 7439-92-1|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Lead
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 7(a)|7(c)-I
  • SCIP notification number (Austria): 41943199-025a-489d-8b9a-531bf841f223
  • SCIP notification number (Belgium): 7965d6b5-7a48-49f8-b116-2a54bcbfff9b
  • SCIP notification number (Bulgaria): b3d2c2f2-c897-4608-b139-b56d742a32c1
  • SCIP notification number (Czech Republic): 5292599a-7b0e-424d-a5f3-7caafc35e33f
  • SCIP notification number (Denmark): 9fcf8dd6-a7be-49d2-8214-f55ba1cfec1a
  • SCIP notification number (Finland): fd91d615-55cf-47df-83fb-3e709ca1c3c2
  • SCIP notification number (France): 99ba37e7-3d9e-4ea9-8f67-0443eff3ad76
  • SCIP notification number (Germany): ff17c057-6d12-4e36-ba06-a915200f6f08
  • SCIP notification number (Hungary): 514207e3-c253-4a2c-bca9-cf4b0f312437
  • SCIP notification number (Italy): e4d86041-5e07-477d-90a1-6361f416baf4
  • SCIP notification number (Netherlands): c8bc4bfb-293d-4753-993e-6135be8383c1
  • SCIP notification number (Poland): 0719f484-78e1-4549-a34f-4f54d0f83ca6
  • SCIP notification number (Romania): 08e28d55-559b-431c-be63-41089606ebc4
  • SCIP notification number (Sweden): e60023e7-1765-4c55-8e22-e833f36d16d7

Environmental requirements

  • Ambient temperature (operation at UN): -40 … +70 °C
  • Ambient temperature (storage): -40 … +70 °C
  • Operating altitude (max.): 2000m
  • Processing temperature: -25 … +50 °C
  • Relative humidity: 5 … 95 % (no condensation permissible)
  • Temperature range of connection cable: ≥ (Tambient + 20 K)

Material data

Mechanical data

  • Mounting position: Horizontal (standing/lying); vertical
  • Mounting type: DIN-35 rail

Notes

  • Note: To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Physical data

  • Depth from upper-edge of DIN-rail: 56 mm / 2.205 inches
  • Height: 91 mm / 3.583 inches
  • Width: 6 mm / 0.236 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 4 kVrms
  • Dielectric strength (open contact) (AC, 1 min): 1 kVrms
  • Insulation type (adjacent devices): Reinforced insulation (safe isolation)
  • Insulation type (control/load circuit): Reinforced insulation (safe isolation)
  • Overvoltage category: III
  • Pollution degree: 2
  • Protection type: IP20; in connected state or when using 859-525 end plate
  • Rated impulse withstand voltage: 4kV
  • Rated voltage: 300V

Standards and specifications

  • Standards/specifications: EN 61010-2-201|EN 61810-1|EN 61373|EN 50121-3-2|DNV

Technical data

  • Control circuit - Input voltage range: ±40 %
  • Control circuit - Nominal input current at UN: 8 mA
  • Control circuit - Nominal input voltage UN: 48 VDC
  • Load circuit - Bounce time (typ.): 3.5ms
  • Load circuit - Contact material (relay): AgSnO2
  • Load circuit - Drop-out time (typ.): 25ms
  • Load circuit - Electrical life (NO; resistive load; 23 °C): 50 x 10³ switching operations
  • Load circuit - Limiting continuous current: 5 A
  • Load circuit - Mechanical life: 5 x 10⁶ switching operations
  • Load circuit - Number of changeover/switchover contacts: 1
  • Load circuit - Pull-in time (typ.): 15ms
  • Load circuit - Recommended minimum load: 10 V / 10 mA; 24 V / 1 mA
  • Load circuit - Switching capacity: AC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC
  • Load circuit - Switching frequency with/without load (max.): 6 min-1 / 180 min-1
  • Load circuit - Switching power (resistive) max.: AC 1250 VA; DC (see load limit curve)
  • Load circuit - Switching Voltage, Max.: 250 VAC
  • Signaling - Status indicator: Red LED