Skip to product information
Wago - 859-390
$29.70
Sale price
$29.70
Regular price
Fixed-type relay module with red LED - for railways applications - WAGO (859 series) - single-pole / 1-pole (1P) - control voltage 16.8-30Vdc (24Vdc nom.; 0.7...1.25 x Uc) - 1C/O / SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 5A (continuous) / 3A (250Vac; AC-15) / 2A (24Vdc; DC-13) - with CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - material Silver-Tin (AgSnO) contacts - equivalent to 859390
Specifications
- Primary brand: WAGO
- Functions: Fixed-type relay module
- Design: red LED|for railways applications|Electromechanical design|10V / 10mA / 24V / 1mA recommended minimum switching load
- Poles: single-pole / 1-pole (1P)
- Temperature: Processing temperature -25°C...+50°C
- Rated current: 5A (continuous)|3A (250Vac; AC-15)|2A (24Vdc; DC-13)
- Rated operating voltage (Ue): 300V
- Rated voltage (AC): 250Vac max. (switching voltage)
- Rated impulse voltage (Uimp): 4kV
- Connection type: CAGE CLAMP connections
- Control Voltage (DC): 16.8-30Vdc (24Vdc nom.; 0.7...1.25 x Uc)
- Mounting mode: DIN-35 rail
- Response time: (OFF=>ON / contacts closing) 6ms / 0.006s|(ON=>OFF / contacts opening) 6ms / 0.006s
- Contacts type: 1C/O / SPDT (Single Pole Double Throw) contact
- Dimensions: H91mm x W6mm x D56mm|6mm width
- Material: Silver-Tin (AgSnO) contacts|Polyamide (PA) 66 housing
- Ambient air temperature for operation: -40°C...+70°C
- Ambient air temperature for storage: -40°C...+70°C
- Humidity: 5-95% relative humidity (RH; non-condensing)
- Electrical durability (with load): 50 000operations
- Mechanical durability (at no load): 5 000 000operations
- ETIM code: EC001437
- Customs Tariff Number: 85364900990
- eClass code: 27-37-16-01
- GTIN code: 4055143607629
- Order code / Manufacturer SKU: 859-390
- Manufacturer product status: Commercialized
- Equivalent to: 859390
- EAN code: 4055143607605
- Compliant with standard(s): Safety and protection|- Overvoltage category -- III|DNV|EN 61010-2-201|EN 61373|EN 61810-1|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03078|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- MFD for Railway - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- DNV - DNV Germany GmbH - DNV-CG-0339 / Aug.2021 - certificate TAA00001D1|Approvals for hazardous areas|- CCC - CNEX - CNCA-C23-01 - certificate 2021312304000982 (Ex ec nC IIC T4 Gc)|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX007X_ec nC|RoHS compliant with exemption (7(a))|material group I|V-0 flammability rating
- Location of origin: China
- Degree of pollution: 2
- Application type: Railways applications
- Level 1 category: Automation components
- Level 2 category: Control components
- Level 3 category: Control relays
- Product title: Fixed-type relay module - WAGO
Commercial data
- Country of origin: CN
- Customs tariff number: 85364900990
- ECCN: NO US CLASSIFICATION
- eCl@ss 10.0: 27-37-16-01
- eCl@ss 9.0: 27-37-16-01
- ETIM 8.0: EC001437
- ETIM 9.0: EC001437
- GTIN: 4055143607629
- Packaging type: box
- Product Group: 6 (INTERFACE ELECTRONIC)
- PU (SPU): 10 pcs
Connection data
- Connection technology: CAGE CLAMP®
- Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Fine-stranded conductor; with insulated ferrule: 0.08 … 1.5 mm² / 28 … 16 AWG
- Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Strip length: 5 … 6 mm / 0.2 … 0.24 inches
Environmental Product Compliance
- CAS-No.: 7439-92-1|79-94-7
- REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Lead
- RoHS Compliance Status: Compliant,With Exemption
- RoHS Exemption: 7(a)
- SCIP notification number (Austria): b80ae32e-17e3-494b-bd67-c82e462fb581
- SCIP notification number (Belgium): 7bca437d-7163-4314-ad00-6d5c2e89959c
- SCIP notification number (Bulgaria): b4d2cc36-ab4c-496b-9e7e-7bb7c557d2e3
- SCIP notification number (Czech Republic): 4e3021bc-9521-4bc5-97ba-9760738bca56
- SCIP notification number (Denmark): 00cad622-a5a6-4fb2-8481-9e7bbf96c3f4
- SCIP notification number (Finland): 4c744e47-cbe4-427d-bbe2-9253e56145f5
- SCIP notification number (France): 97e502b0-2db1-430e-a345-cd6118c123b2
- SCIP notification number (Germany): e8d89f4c-5b4d-4810-b2e5-eaa149c4b9a4
- SCIP notification number (Hungary): 5f5a0e35-6873-4a2c-bd24-e453f0c7a31e
- SCIP notification number (Italy): 741e839c-bbd6-47d1-8d3d-d6c1d1bc11ce
- SCIP notification number (Netherlands): 1721e0ca-aa62-442e-b50e-073d56d21186
- SCIP notification number (Poland): fffd907d-c5ea-4395-a795-4496c3dadb1f
- SCIP notification number (Romania): bb944c68-d93e-4936-a2c6-f83d009e6f49
- SCIP notification number (Sweden): 6cab1041-53ac-4e56-b2f4-c32162d6086f
Environmental requirements
- Ambient temperature (operation at UN): -40 … +70 °C
- Ambient temperature (storage): -40 … +70 °C
- Operating altitude (max.): 2000m
- Processing temperature: -25 … +50 °C
- Relative humidity: 5 … 95 % (no condensation permissible)
- Temperature range of connection cable: ≥ (Tambient + 20 K)
Material data
- Color: gray
- Fire load: 1.274MJ
- Flammability class per UL94: V0
- Insulation material (main housing): Polyamide (PA66)
- Material group: I
-
Note (material data):
Information on material specifications can be found here
- Weight: 22.9g
Mechanical data
- Mounting position: Horizontal (standing/lying); vertical
- Mounting type: DIN-35 rail
Notes
- Note: To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
Physical data
- Depth from upper-edge of DIN-rail: 56 mm / 2.205 inches
- Height: 91 mm / 3.583 inches
- Width: 6 mm / 0.236 inches
Safety and protection
- Dielectric strength (control/load circuit) (AC, 1 min): 4 kVrms
- Dielectric strength (open contact) (AC, 1 min): 1 kVrms
- Insulation type (adjacent devices): Reinforced insulation (safe isolation)
- Insulation type (control/load circuit): Reinforced insulation (safe isolation)
- Overvoltage category: III
- Pollution degree: 2
- Protection type: IP20; in connected state or when using 859-525 end plate
- Rated impulse withstand voltage: 4kV
- Rated voltage: 300V
Standards and specifications
- Standards/specifications: EN 61010-2-201|EN 61810-1|EN 61373|UL 508|DNV
Technical data
- Control circuit - Input voltage range: -30 … +25 %
- Control circuit - Nominal input current at UN: 12 mA
- Control circuit - Nominal input voltage UN: 24 VDC
- Load circuit - Bounce time (typ.): 3.5ms
- Load circuit - Contact material (relay): AgSnO2
- Load circuit - Drop-out time (typ.): 6ms
- Load circuit - Electrical life (NO; resistive load; 23 °C): 50 x 10³ switching operations
- Load circuit - Limiting continuous current: 5 A
- Load circuit - Mechanical life: 5 x 10⁶ switching operations
- Load circuit - Number of changeover/switchover contacts: 1
- Load circuit - Pull-in time (typ.): 6ms
- Load circuit - Recommended minimum load: 10 V / 10 mA; 24 V / 1 mA
- Load circuit - Switching capacity: AC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC
- Load circuit - Switching frequency with/without load (max.): 6 min-1 / 180 min-1
- Load circuit - Switching power (resistive) max.: AC 1250 VA; DC (see load limit curve)
- Load circuit - Switching Voltage, Max.: 250 VAC
- Signaling - Status indicator: Red LED