Wago - 857-642

Wago - 857-642

$215.30
Sale price  $215.30 Regular price 
Skip to product information
Wago - 857-642

Wago - 857-642

$215.30
Sale price  $215.30 Regular price 

Fixed-type timing relay module with ON- and OFF-delay switching + 2 x separate adjustable time ranges + yellow LED - for railways applications - WAGO (857 series) - single-pole / 1-pole (1P) - control voltage 16.8-31.2Vdc (24Vdc nom.; 0.7...1.3 x Uc; SELV) - 1C/O / SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 6A (continuous) / 3A (250Vac; AC-15) / 2A (24Vdc; DC-13) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - IP20 - material Silver-Tin (AgSnO) contacts - equivalent to 857642

Specifications

  • Primary brand: WAGO
  • Functions: Fixed-type timing relay module
  • Design: ON- and OFF-delay switching|2 x separate adjustable time ranges|yellow LED|for railways applications|Electromechanical design|10V / 10mA / 24V / 1mA recommended minimum switching load
  • Poles: single-pole / 1-pole (1P)
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 6A (continuous)|3A (250Vac; AC-15)|2A (24Vdc; DC-13)|20A (20ms) AC inrush maximum current
  • Rated operating voltage (Ue): 250V
  • Rated voltage (AC): 250Vac max. (switching voltage)
  • Rated impulse voltage (Uimp): 4kV
  • Connection type: Push-in CAGE CLAMP connections
  • Control Voltage (DC): 16.8-31.2Vdc (24Vdc nom.; 0.7...1.3 x Uc; SELV)
  • Mounting mode: DIN-35 rail
  • Time delay: adjustable time range 0.01-0.1s / 0.1-1s / 1-10s / 10-100s / 1-10min / 10-100min / 1-10h / 10-100h|50ms (reset time)
  • Response time: (OFF=>ON / contacts closing) 15ms / 0.015s|(ON=>OFF / contacts opening) 25ms / 0.025s
  • Contacts type: 1C/O / SPDT (Single Pole Double Throw) contact
  • Dimensions: H94mm x W6mm x D97.8mm|6mm width
  • Material: Silver-Tin (AgSnO) contacts|Polyamide (PA) 66 housing
  • Ambient air temperature for operation: -25°C...+70°C
  • Ambient air temperature for storage: -40°C...+70°C
  • Humidity: 5-85% relative humidity (RH; non-condensing)
  • Electrical durability (with load): 50 000operations
  • Mechanical durability (at no load): 5 000 000operations
  • ETIM code: EC001439
  • eClass code: 27-37-16-05
  • Customs Tariff Number: 85364900990
  • GTIN code: 4050821565710
  • Order code / Manufacturer SKU: 857-642
  • Manufacturer product status: Commercialized
  • Equivalent to: 857642
  • EAN code: 4050821565710
  • Compliant with standard(s): Safety and protection|- Overvoltage category -- II|EN 50121-3-2|EN 61010-2-201|EN 61373|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03078|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)|V-0 flammability rating
  • Location of origin: Germany
  • Degree of pollution: 2
  • Application type: Railways applications
  • Benefits: On- and off-delay|control input - ON-delay and single-shot leading edge - ON-delay and single-shot leading edge|control input - Single-shot leading and trailing edge|control input - Pulse sequence evaluation|control input - Repeat cycle timer|pulse start - Repeat cycle timer|interval start|control input
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Fixed-type timing relay module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85364900990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-37-16-05
  • eCl@ss 9.0: 27-37-16-05
  • ETIM 8.0: EC001439
  • ETIM 9.0: EC001439
  • GTIN: 4050821565710
  • Packaging type: bag
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 1 pcs

Connection data

  • Connection technology: Push-in CAGE CLAMP®
  • Fine-stranded conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Solid conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Strip length: 9 … 10 mm / 0.35 … 0.39 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): 3b577f50-a8f7-4931-8018-0273f6744d4b
  • SCIP notification number (Belgium): 889e1473-2ccc-4f3e-a962-66f08b6b9513
  • SCIP notification number (Bulgaria): 35d84d84-84a7-48a5-8e85-d9c076d92980
  • SCIP notification number (Czech Republic): 136b2103-8f85-44a8-80b6-7238b933cda1
  • SCIP notification number (Denmark): dd71aaca-a453-4adc-8364-11c848085ff8
  • SCIP notification number (Finland): af04b623-8bd2-47b4-abce-f53cba388b21
  • SCIP notification number (France): 5c6fb437-6cee-4fad-8189-fa67b2d0d9fd
  • SCIP notification number (Germany): 73a17d4f-a9bb-46af-bbc7-f6877f9a6d4f
  • SCIP notification number (Hungary): 522673c1-1804-4e5a-9498-50e0be68fdf0
  • SCIP notification number (Italy): 5bd150b2-0987-4017-bfb4-1981a4b51fe7
  • SCIP notification number (Netherlands): 0b76abbd-17a8-4f64-8a2e-aa807581c02d
  • SCIP notification number (Poland): 19f39985-f039-470b-ab2a-201a399fb747
  • SCIP notification number (Romania): 5374616e-6c99-43e6-841d-734dff001fba
  • SCIP notification number (Sweden): dd5fcbe1-4312-41f3-824d-0cdb44fc18be

Environmental requirements

  • Ambient temperature (operation at UN): -25 … +70 °C
  • Ambient temperature (storage): -40 … +70 °C
  • Operating altitude (max.): 2000m
  • Processing temperature: -25 … +50 °C
  • Relative humidity: 5 … 85 % (no condensation permissible)
  • Temperature range of connection cable: ≥ (Tambient + 30 K)

Material data

Mechanical data

  • Mounting type: DIN-35 rail

Notes

  • Note: The 6 (GND) and 8 (GND) connections are internally commoned. The current carrying capacity is: 4 A (max.)

Physical data

  • Depth from upper-edge of DIN-rail: 97.8 mm / 3.85 inches
  • Height: 94 mm / 3.701 inches
  • Width: 6 mm / 0.236 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 3.51 kVrms
  • Dielectric strength (open contact) (AC, 1 min): 1 kVrms
  • Overvoltage category: II
  • Pollution degree: 2
  • Protection type: IP20
  • Rated impulse withstand voltage: 4kV
  • Rated voltage: 250V

Standards and specifications

  • Standards/specifications: EN 61373|EN 50121-3-2|UL 508|EN 61010-2-201

Technical data

  • Control circuit - Functions: On- and off-delay (with control input)|On-delay and single-shot leading edge|On-delay and single-shot leading edge (with control input)|Single-shot leading and trailing edge (with control input)|Pulse sequence evaluation (with control input)|Repeat cycle timer (pulse start)|Repeat cycle timer (interval start), control input
  • Control circuit - Input voltage range: ±30 %
  • Control circuit - Minimum pulse length (control input): 10ms
  • Control circuit - Nominal input current at UN: 18 mA
  • Control circuit - Nominal input voltage UN: 24 VDC (SELV)
  • Control circuit - Reset time: 50ms
  • Control circuit - Time range: Adjustable: 0.01 … 0.1 s; 0.1 … 1 s; 1 … 10 s; 10 … 100 s; 1 … 10 min; 10 … 100 min; 1 … 10 h; 10 … 100 h
  • Load circuit - Bounce time (typ.): 3.5ms
  • Load circuit - Contact material (relay): AgSnO2
  • Load circuit - Digital output (DO): UN - 1 V ; 100 mA
  • Load circuit - Drop-out time (typ.): 25ms
  • Load circuit - Electrical life (NO; resistive load; 23 °C): 50 x 10³ switching operations
  • Load circuit - Inrush current (resistive) max.: (AC) 20 A / 0.02 s
  • Load circuit - Limiting continuous current: 6 A
  • Load circuit - Mechanical life: 5 x 10⁶ switching operations
  • Load circuit - Number of changeover/switchover contacts: 1
  • Load circuit - Pull-in time (typ.): 15ms
  • Load circuit - Recommended minimum load: 10 V / 10 mA; 24 V / 1 mA
  • Load circuit - Short circuit protection (load circuit): 6.3 A; Slow (T); testing based on EN 61812-1 with a short-circuit current of 100 ADC
  • Load circuit - Switching capacity: AC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC
  • Load circuit - Switching power (resistive) max.: AC 1500 VA; DC (see load limit curve)
  • Load circuit - Switching Voltage, Max.: 250 VAC
  • Signaling - Status indicator: Yellow LED

You may also like