Plug-in relay assembly with socket base + red LED - WAGO (788 series) - single-pole / 1-pole (1P) - control voltage 207-253Vac (230Vac nom.; 0.9...1.1 x Uc) - 1C/O / SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 50mA (30Vdc; DC-13) (max. recommended current to avoid evaporating the Gold flash) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (15mm width) - IP20 - material Hard Gold-plated Silver-Nickel (AgNi + Au) contacts - equivalent to 788608

Specifications

  • Primary brand: WAGO
  • Functions: Plug-in relay assembly
  • Design: socket base|red LED|Electromechanical design|5V / 2mA / 50mW recommended minimum switching load
  • Poles: single-pole / 1-pole (1P)
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 50mA (30Vdc; DC-13) (max. recommended current to avoid evaporating the Gold flash)|16A (continuous)|6A (AC-15; 250Vac)|2A (DC-13; 24Vdc)
  • Rated operating voltage (Ue): 250V
  • Rated voltage (AC): 250Vac max. (switching voltage)
  • Rated impulse voltage (Uimp): 4kV
  • Connection type: Push-in CAGE CLAMP connections
  • Control Voltage (AC): 207-253Vac (230Vac nom.; 0.9...1.1 x Uc)
  • Mounting mode: DIN-35 rail
  • Response time: (OFF=>ON / contacts closing) 7ms / 0.007s|(ON=>OFF / contacts opening) 3ms / 0.003s
  • Contacts type: 1C/O / SPDT (Single Pole Double Throw) contact
  • Dimensions: H86mm x W15mm x D54mm|15mm width
  • Material: Hard Gold-plated Silver-Nickel (AgNi + Au) contacts
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+70°C
  • Electrical durability (with load): 70 000operations
  • Mechanical durability (at no load): 30 000 000operations
  • Customs Tariff Number: 85364900990
  • ETIM code: EC001437
  • eClass code: 27-37-16-01
  • GTIN code: 4055143998055
  • Order code / Manufacturer SKU: 788-608
  • Manufacturer product status: Commercialized
  • Equivalent to: 788608
  • EAN code: 4055143998055
  • Compliant with standard(s): Safety and protection|Safety information -- A separator plate must be used for voltages greater than 250V between adjacent relay modules|and for compliance with the reinforced insulation requirements.|DNV|EN 61010-2-201|EN 61373|EN 61810-1|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03084|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Vol.1 Sec.6|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- DNV - DNV Germany GmbH - DNV-CG-0339 / Aug.2021 - certificate TAA00001D1|RoHS compliant with exemption (7(a))
  • Location of origin: Germany
  • Degree of pollution: 3
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Plug-in relay assembly - WAGO

Basic relay

  • WAGO Basic Relay: 788-179

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85364900990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-37-16-01
  • eCl@ss 9.0: 27-37-16-01
  • ETIM 8.0: EC001437
  • ETIM 9.0: EC001437
  • GTIN: 4055143998055
  • Packaging type: box
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 20 (1) pcs

Connection data

  • Connection technology: Push-in CAGE CLAMP®
  • Fine-stranded conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Solid conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Strip length: 9 … 10 mm / 0.35 … 0.39 inches

Environmental Product Compliance

  • CAS-No.: 7439-92-1|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Lead
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 7(a)
  • SCIP notification number (Austria): 3694ca5b-67a6-4ebe-8f3c-414eda20fab5
  • SCIP notification number (Belgium): 555a9059-b58d-42cd-9788-ff1e3dcddeb6
  • SCIP notification number (Bulgaria): 0ac4afdb-60a6-4bf3-8c29-71aa75ef352b
  • SCIP notification number (Czech Republic): 214597cc-7c59-45ea-9f2d-d7af98952dcd
  • SCIP notification number (Denmark): d8b08b82-e6f0-4bf4-960a-e4bcb748e26a
  • SCIP notification number (Finland): 63baaebc-312d-4abe-9ac5-66e2601788bd
  • SCIP notification number (France): c99520af-ad87-4921-aed9-ecfc6ab1d0c4
  • SCIP notification number (Germany): eee2b7b4-7f80-43c9-8590-ac2fdde0c662
  • SCIP notification number (Hungary): 63b4f2b2-6cd6-4744-9c85-e4c5c917aabf
  • SCIP notification number (Italy): 1046d58c-c060-44b4-94c4-d5d289f08922
  • SCIP notification number (Netherlands): 54f28c8b-006b-4d9a-a9b9-115c62c5fdca
  • SCIP notification number (Poland): 3ccd9e55-19c1-4aa0-8e25-99071c6889c3
  • SCIP notification number (Romania): 50426f91-9aff-4b7b-8c44-73776e0778b9
  • SCIP notification number (Sweden): 2bd076d7-174e-41c5-9079-3b2dda0c9e81

Environmental requirements

  • Ambient temperature (operation at UN): -40 … +70 °C
  • Ambient temperature (storage): -40 … +70 °C
  • Ambient temperature UL (operation at UN): -40 … +50 °C
  • Processing temperature: -25 … +50 °C
  • Temperature range of connection cable: ≥ (Tambient + 20 K)

Material data

Mechanical data

  • Mounting type: DIN-35 rail

Notes

  • Note: Reinforced insulation between coil and contacts|To prevent damaging the gold layer, 30 VDC switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life.|To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
  • Safety Information: A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.

Physical data

  • Depth from upper-edge of DIN-rail: 54 mm / 2.126 inches
  • Height: 86 mm / 3.386 inches
  • Width: 15 mm / 0.591 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 5 kVrms
  • Dielectric strength (open contact) (AC, 1 min): 1 kVrms
  • Pollution degree: 3
  • Protection type: IP20
  • Rated impulse withstand voltage: 4kV
  • Rated voltage: 250V
  • Safety Information: A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.

Standards and specifications

  • Standards/specifications: EN 61010-2-201|EN 61810-1|EN 61373|UL 508|DNV

Technical data

  • Control circuit - Input voltage range: ±10 %
  • Control circuit - Nominal input current at UN: 5 mA
  • Control circuit - Nominal input voltage UN: 230 VAC
  • Load circuit - Bounce time (typ.): 6ms
  • Load circuit - Contact material (relay): AgNi + Au
  • Load circuit - Drop-out time (typ.): 3ms
  • Load circuit - Electrical life (NO; resistive load; 23 °C): 70 x 10³ switching operations
  • Load circuit - Limiting continuous current: 16 A
  • Load circuit - Mechanical life: 30 x 10⁶ switching operations
  • Load circuit - Number of changeover/switchover contacts: 1
  • Load circuit - Pull-in time (typ.): 7ms
  • Load circuit - Recommended minimum load: 5 V / 2 mA / 50 mW
  • Load circuit - Switching capacity: AC-15: 6 A / 250 VAC; DC-13: 2 A / 24 VDC
  • Load circuit - Switching frequency with/without load (max.): 10 min-1 / 1200 min-1
  • Load circuit - Switching power (resistive) max.: AC 4000 VA; DC (see load limit curve)
  • Load circuit - Switching Voltage, Max.: 250 VAC
  • Signaling - Status indicator: Red LED