Plug-in relay assembly with socket base + red LED - WAGO (788 series) - single-pole / 1-pole (1P) - control voltage 21.6-26.4Vac (24Vac nom.; 0.9...1.1 x Uc) - 1C/O / SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 16A (continuous) / 6A (250Vac; AC-15) / 2A (24Vdc; DC-13) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (15mm width) - IP20 - material Silver-Nickel (AgNi 90/10) contacts - equivalent to 788506

Specifications

  • Primary brand: WAGO
  • Functions: Plug-in relay assembly
  • Design: socket base|red LED|Electromechanical design|12V / 10mA recommended minimum switching load
  • Poles: single-pole / 1-pole (1P)
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 16A (continuous)|6A (250Vac; AC-15)|2A (24Vdc; DC-13)|30A (4s) AC inrush maximum current
  • Rated operating voltage (Ue): 250V
  • Rated voltage (AC): 250Vac max. (switching voltage)
  • Rated impulse voltage (Uimp): 4kV
  • Connection type: Push-in CAGE CLAMP connections
  • Control Voltage (AC): 21.6-26.4Vac (24Vac nom.; 0.9...1.1 x Uc)
  • Mounting mode: DIN-35 rail
  • Response time: (OFF=>ON / contacts closing) 10ms / 0.010s|(ON=>OFF / contacts opening) 35ms / 0.035s
  • Contacts type: 1C/O / SPDT (Single Pole Double Throw) contact
  • Dimensions: H86mm x W15mm x D54mm|15mm width
  • Material: Silver-Nickel (AgNi 90/10) contacts
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+70°C
  • Electrical durability (with load): 30 000operations
  • Mechanical durability (at no load): 5 000 000operations
  • Customs Tariff Number: 85364900990
  • eClass code: 27-37-16-01
  • GTIN code: 4045454424121
  • ETIM code: EC001437
  • Order code / Manufacturer SKU: 788-506
  • Manufacturer product status: Commercialized
  • Equivalent to: 788506
  • EAN code: 4045454424121
  • Compliant with standard(s): Safety and protection|Safety information -- A separator plate must be used for voltages greater than 250V between adjacent relay modules|and for compliance with the reinforced insulation requirements.|DNV|EN 61010-2-201|EN 61373|EN 61810-1|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03084|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Vol.1 Sec.6|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- DNV - DNV Germany GmbH - DNV-CG-0339 / Aug.2021 - certificate TAA00001D1|- PRS - Polski Rejestr Statkow - certificate TE/1098/880590/23|RoHS compliant
  • Location of origin: Germany
  • Degree of pollution: 3
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Plug-in relay assembly - WAGO

Basic relay

  • WAGO Basic Relay: 788-170

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85364900990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-37-16-01
  • eCl@ss 9.0: 27-37-16-01
  • ETIM 8.0: EC001437
  • ETIM 9.0: EC001437
  • GTIN: 4045454424121
  • Packaging type: box
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 20 (1) pcs

Connection data

  • Connection technology: Push-in CAGE CLAMP®
  • Fine-stranded conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Solid conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Strip length: 9 … 10 mm / 0.35 … 0.39 inches

Environmental Product Compliance

  • CAS-No.: 80-05-7
  • REACH Candidate List Substance: 4,4'-isopropylidenediphenol
  • RoHS Compliance Status: Compliant,No Exemption
  • SCIP notification number (Austria): 909324ad-5e3b-4d39-ad4f-2fbc4d58bde5
  • SCIP notification number (Belgium): 2c9fa0df-83b1-4815-91a2-7420bb644f3d
  • SCIP notification number (Bulgaria): d4bc7641-1e5c-454e-977e-43e41bda5d2b
  • SCIP notification number (Czech Republic): 185a21da-bc74-4fab-9583-08d99a980130
  • SCIP notification number (Denmark): 5d95b346-802a-4648-9638-9a67776bd077
  • SCIP notification number (Finland): 6307942c-93c4-4d51-9c5d-112763aa753c
  • SCIP notification number (France): 101db39d-73f5-4185-bf71-1dfa3c602d18
  • SCIP notification number (Germany): 0c83fb69-743e-42a6-a8b0-58d28f4344c9
  • SCIP notification number (Hungary): 330a7887-84f7-4a37-aeca-9a0d031f6c07
  • SCIP notification number (Italy): d5373a56-298a-4009-a1f0-ab3127f4bdb0
  • SCIP notification number (Netherlands): 45ab6da9-0832-49bd-9e11-62137072e4c0
  • SCIP notification number (Poland): e660e88e-4666-4e59-a612-4a6409aa3aca
  • SCIP notification number (Romania): 1249d728-d991-4cbb-90d2-afb832e9a5cd
  • SCIP notification number (Sweden): 4cc42db8-2306-423c-8bfe-e1ab465fd20a

Environmental requirements

  • Ambient temperature (operation at UN): -40 … +70 °C
  • Ambient temperature (storage): -40 … +70 °C
  • Ambient temperature UL (operation at UN): -40 … +50 °C
  • Processing temperature: -25 … +50 °C
  • Temperature range of connection cable: ≥ (Tambient + 20 K)

Material data

Mechanical data

  • Mounting type: DIN-35 rail

Notes

  • Note: Reinforced insulation between coil and contacts|To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
  • Safety Information: A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.

Physical data

  • Depth from upper-edge of DIN-rail: 54 mm / 2.126 inches
  • Height: 86 mm / 3.386 inches
  • Width: 15 mm / 0.591 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 5 kVrms
  • Dielectric strength (open contact) (AC, 1 min): 1 kVrms
  • Pollution degree: 3
  • Protection type: IP20
  • Rated impulse withstand voltage: 4kV
  • Rated voltage: 250V
  • Safety Information: A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.

Standards and specifications

  • Standards/specifications: EN 61010-2-201|EN 61810-1|EN 61373|UL 508|DNV

Technical data

  • Control circuit - Input voltage range: ±10 %
  • Control circuit - Nominal input current at UN: 34 mA
  • Control circuit - Nominal input voltage UN: 24 VAC
  • Load circuit - Bounce time (typ.): 6ms
  • Load circuit - Contact material (relay): AgNi 90/10
  • Load circuit - Drop-out time (typ.): 35ms
  • Load circuit - Electrical life (NO; resistive load; 23 °C): 30 x 10³ switching operations
  • Load circuit - Inrush current (resistive) max.: (AC) 30 A / 4 s
  • Load circuit - Limiting continuous current: 16 A
  • Load circuit - Mechanical life: 5 x 10⁶ switching operations
  • Load circuit - Number of changeover/switchover contacts: 1
  • Load circuit - Pull-in time (typ.): 10ms
  • Load circuit - Recommended minimum load: 12 V / 10 mA
  • Load circuit - Switching capacity: AC-15: 6 A / 250 VAC; DC-13: 2 A / 24 VDC
  • Load circuit - Switching frequency with/without load (max.): 6 min-1 / 600 min-1
  • Load circuit - Switching power (resistive) max.: AC 4000 VA; DC (see load limit curve)
  • Load circuit - Switching Voltage, Max.: 250 VAC
  • Signaling - Status indicator: Red LED