Binary spacer module - WAGO (750 series) - Binary Spacer Module - supply voltage 24Vdc - Rated current 10A - Light Gray color - with Push-in spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - equivalent to 750622
Specifications
- Primary brand: WAGO
- Functions: Binary spacer module
- Supply voltage (DC): 24Vdc
- Display: LED (A/C); (B) green -- data width; input/output operating mode
- Rated current: 10A
- Color: Light Gray
- Connection type: Push-in spring CAGE CLAMP connections
- Mounting mode: DIN-35 rail
- Dimensions: H100mm x W12mm x D69.8mm
- Net Width (mm): 12mm
- Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
- Ambient air temperature for operation: 0°C...+55°C
- Ambient air temperature for storage: -40°C...+85°C
- Humidity: 95% relative humidity (RH; non-condensing)
- Mechanical resistance: Shock resistance according to EN 60068-2-27 --15g
- Current consumption: 10mA (5Vdc; system supply)
- GTIN code: 4045454721749
- eClass code: 27-24-26-10
- Customs Tariff Number: 85389091890
- ETIM code: EC001600
- Order code / Manufacturer SKU: 750-622
- Manufacturer product status: Commercialized
- Equivalent to: 750622
- EAN code: 4045454721749
- Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-4|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-END750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (7(c)-I)
- Location of origin: Germany
- Degree of pollution: 2
- Level 1 category: Automation components
- Product title: Binary spacer module - WAGO
Commercial data
- Country of origin: DE
- Customs tariff number: 85389091890
- ECCN: NO US CLASSIFICATION
- eCl@ss 10.0: 27-24-26-10
- eCl@ss 9.0: 27-24-26-10
- ETIM 8.0: EC001600
- ETIM 9.0: EC001600
- GTIN: 4045454721749
- Packaging type: box
- Product Group: 15 (I/O System)
- PU (SPU): 1 pcs
Connection data
- Connectable conductor materials: Copper
- Connection technology: field supply: 6 x CAGE CLAMP®
- Connection type 1: Field supply
- Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Strip length: 8 … 9 mm / 0.31 … 0.35 inches
Environmental Product Compliance
- CAS-No.: 1303-86-2|25550-51-0|7439-92-1
- REACH Candidate List Substance: 4-Methyl-1,2-cyclohexanedicarboxylic anhydride|Diboron trioxide|Lead
- RoHS Compliance Status: Compliant,With Exemption
- RoHS Exemption: 7(c)-I
- SCIP notification number (Austria): a783e786-6cc9-4c97-ba5a-cfaa6e1f0952
- SCIP notification number (Belgium): 6fcd2973-8df1-43fa-9243-c2df44e198fc
- SCIP notification number (Bulgaria): df499c3f-8321-47c2-80d8-3fffadb8d3e6
- SCIP notification number (Czech Republic): 052843e5-9a00-4008-ac82-e0620aaae1f4
- SCIP notification number (Denmark): 894f6b14-458a-4ae3-b7e1-be8dd753493c
- SCIP notification number (Finland): 28d97981-97bd-4cd9-ac02-d1e4755fb0db
- SCIP notification number (France): 2fe03a3a-d8ea-4052-ac81-aff622a187f4
- SCIP notification number (Germany): 16aa058d-ff58-4585-af87-325921be9148
- SCIP notification number (Hungary): 6e51330f-8cfd-449e-b078-84a9fa29c56b
- SCIP notification number (Italy): 6f7e3d0b-c985-4319-9996-e27bbaaf152f
- SCIP notification number (Netherlands): 02f93804-8641-4eac-827b-b171fb354412
- SCIP notification number (Poland): 972e7d12-ba5c-4b50-b277-d30cb509f2d4
- SCIP notification number (Romania): 9c898b61-c111-4bd4-a412-ae810488a382
- SCIP notification number (Sweden): 68b1348a-4926-4871-94c4-cbcb1bd00602
Environmental requirements
- Ambient temperature (operation): 0 … +55 °C
- Ambient temperature (storage): -40 … +85 °C
- EMC emission of interference: per EN 61000-6-4
- EMC immunity to interference: per EN 61000-6-2
- Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
- Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
- Operating altitude: 0 … 2000 m / 0 … 6562 ft
-
Permissible H2S contaminant concentration at a relative humidity
75 %: 10ppm -
Permissible SO2 contaminant concentration at a relative humidity
75 %: 25ppm - Pollution degree: 2 per IEC 61131-2
- Protection type: IP20
- Relative humidity (without condensation): 95%
- Shock resistance: 15g per IEC 60068-2-27
- Vibration resistance: per IEC 60068-2-6
Material data
- Color: light gray
- Conformity marking: CE
- Fire load: 1.38MJ
- Housing material: Polycarbonate; polyamide 6.6
- Weight: 44.9g
Mechanical data
- Mounting type: DIN-35 rail
Physical data
- Depth: 69.8 mm / 2.748 inches
- Depth from upper-edge of DIN-rail: 62.6 mm / 2.465 inches
- Height: 100 mm / 3.937 inches
- Width: 12 mm / 0.472 inches
Technical data
- Current carrying capacity (power jumper contacts): 10A
- Current consumption (5 V system supply): 10mA
- Data width: 2, 4, 6 or 8 bits (adjustable via DIP switches)
- Indicators: LED (A, C); (B) green: data width; input/output operating mode
- Isolation: 500 V system/field
- Number of outgoing power jumper contacts: 3
- Operating mode: Inputs DIP 3: OFF; Outputs DIP 3: ON
- Supply voltage (field): 24 VDC (-15 … +20 %); via power jumper contacts (power supply via CAGE CLAMP® connection; transmission (field-side supply voltage only) via spring contact
- Supply voltage (system): 5 VDC; via data contacts