Standard analog output slice unit module - WAGO (750 series) - 4I/O [4AO (4 x analog inputs (0-10mA / 2-10mA / -10...+10mA / 0-20mA / 4-20mA / -20...+20mA / 0-22mA / -22...+22mA / 0-12mA / -12...+12mA / 0-5V / 1-5V / -5...+5V / 0-10V / 2-10V / -10...+10V / 0-12V / -12...+12V; Differential; Isolated; 16-bits / 3ms conversion))] - supply voltage 5Vdc (supplied by system) - with Push-in spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750564

Specifications

  • Primary brand: WAGO
  • Functions: Standard analog output slice unit module|Configuration options|- WAGO-I/O-CHECK|- CODESYS Library|- e!COCKPIT
  • Supply voltage (DC): 5Vdc (supplied by system)|18-31.2Vdc adjustable suppl. to field sensing devices
  • Connection type: Push-in spring CAGE CLAMP connections
  • Mounting mode: DIN-35 rail
  • Analog outputs: 4 x analog inputs (0-10mA / 2-10mA / -10...+10mA / 0-20mA / 4-20mA / -20...+20mA / 0-22mA / -22...+22mA / 0-12mA / -12...+12mA / 0-5V / 1-5V / -5...+5V / 0-10V / 2-10V / -10...+10V / 0-12V / -12...+12V; Differential; Isolated; 16-bits / 3ms conversion)
  • Dimensions: H100mm x W12mm x D69mm
  • Net Width (mm): 12mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Shock resistance according to EN 60068-2-27 --15g
  • Current consumption: 55mA (5Vdc; system supply)
  • ETIM code: EC001596
  • Customs Tariff Number: 85389099990
  • GTIN code: 4055143933223
  • Order code / Manufacturer SKU: 750-564
  • Manufacturer product status: Commercialized
  • Equivalent to: 750564
  • EAN code: 4055143933223
  • Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-3|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-AOM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- BSH - Bundesamt fuer Seeschifffahrt und Hydrographie - certificate 1104|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 66711/A0|- DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194|- KR - Korean Register of Shipping - certificate KR HMB05880-AC001|- PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Standard analog output slice unit module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85389099990
  • ECCN: NO US CLASSIFICATION
  • ETIM 8.0: EC001596
  • ETIM 9.0: EC001596
  • GTIN: 4055143933223
  • Packaging type: box
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: inputs/outputs: 16 x Push-in CAGE CLAMP®
  • Connection type 1: Inputs/Outputs
  • Fine-stranded conductor: 0.25 … 1.5 mm² / 22 … 16 AWG
  • Solid conductor: 0.08 … 1.5 mm² / 28 … 16 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1
  • REACH Candidate List Substance: Diboron trioxide|Lead|Lead monoxide
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): ff605b72-1492-4eea-9540-1b10a4e14799
  • SCIP notification number (Belgium): 6a38898c-c23c-4020-892c-9d000e0e599d
  • SCIP notification number (Bulgaria): 76060568-a696-456c-8df1-15068ddae193
  • SCIP notification number (Czech Republic): ef4e81d6-7c41-48d8-85eb-cbf0c1342f1e
  • SCIP notification number (Denmark): 439e8787-5feb-4a13-8c47-0f47a5c15fe3
  • SCIP notification number (Finland): 3b28c00f-c0c3-42e2-9c8a-5aaadb1d3175
  • SCIP notification number (France): eb5c9baa-4301-427c-a15f-be6b86254555
  • SCIP notification number (Germany): 752bd75f-a999-4db8-a314-d67481047d66
  • SCIP notification number (Hungary): 4808eb04-de68-43cb-9240-bfde84ecb644
  • SCIP notification number (Italy): e4d68597-2633-42ac-9cd6-838d61cebad8
  • SCIP notification number (Netherlands): 298d87f9-e91b-4799-bce6-dfda9d0e0c0b
  • SCIP notification number (Poland): 4fe1d60a-ced7-4c3c-b0cd-8f8b9a7f5631
  • SCIP notification number (Romania): 19c7ac7f-1b97-4342-b605-787060b72971
  • SCIP notification number (Sweden): bf2e9e26-969f-427b-9740-ce4e3fda6797

Environmental requirements

  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -40 … +85 °C
  • EMC emission of interference: per EN 61000-6-3
  • EMC immunity to interference: per EN 61000-6-2
  • Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
  • Operating altitude: 0 … 2000 m / 0 … 6562 ft
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (without condensation): 95%
  • Shock resistance: 15g per IEC 60068-2-27

Material data

  • Conformity marking: CE
  • Fire load: 0.848MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 51g

Mechanical data

  • Mounting type: DIN-35 rail

Physical data

  • Depth: 69 mm / 2.717 inches
  • Depth from upper-edge of DIN-rail: 61.8 mm / 2.433 inches
  • Height: 100 mm / 3.937 inches
  • Width: 12 mm / 0.472 inches

Technical data

  • Actuator connection: 4 x (2-wire); Voltage outputs can optionally be connected in 4-wire technology via the sense lines.
  • Configuration options: WAGO-I/O-CHECK|CODESYS Library|e!COCKPIT
  • Conversion time (typ.): 3ms
  • Current consumption (5 V system supply): 55mA
  • Data width: 4 x 16-bit data; 4 x 8-bit control/status (optional)
  • Indicators: LED (1-4) green: Status AO 1 … AO 4; LED (9-12) red: Error AO 1 … AO 4
  • Isolation: 500 V system/field
  • Load impedance (current output): ≤ 600 Ω
  • Load impedance (voltage output): ≥ 1 kΩ
  • Number of analog outputs: 4
  • Number of incoming power jumper contacts: 2
  • Number of outgoing power jumper contacts: 2
  • Output error, deviation (max.) of the upper-range value: 0.05%
  • Output error, reference temperature: 25.°C
  • Reference for measurement error: Voltage/Current
  • Resolution [bit]: 16bits
  • Signal type: Voltage|Current
  • Signal type (current): 0 … 10 mA; 2 … 10 mA; -10 … +10 mA; 0 … 20 mA; 4 … 20 mA; -20 … +20 mA; 0 … 22 mA; -22 … +22 mA; 0 … 12 mA; -12 … +12 mA
  • Signal type (voltage): 0 … 5 V; 1 … 5 V; -5 … +5 V; 0 … 10 V; 2 … 10 V; -10 … +10 V; 0 … 12 V; -12 … +12 V
  • Supply voltage (field): 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)
  • Supply voltage (system): 5 VDC; via data contacts
  • Temperature coefficient: U: ±25 ppm/K of the upper-range value; I: ±50 ppm/K of the upper-range value
  • Total number of channels (module): 4