Fieldbus coupler / head (remote I/O (RIO) controller unit) - WAGO (750 series) - FC CC-Link - 64 x connections per node + 64 x fieldbus nodes on master connection capability - with CC-Link communication capability - supply voltage 24Vdc via wiring (system) + 24Vdc via pwr. jumper (Field) - with 4-pin male connector (fieldbus) - DIN-35 rail mounting (61.5mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750325

Specifications

  • Primary brand: WAGO
  • Functions: Fieldbus coupler / head (remote I/O (RIO) controller unit)
  • Supply voltage (DC): 24Vdc via wiring (system) + 24Vdc via pwr. jumper (Field)
  • Connection capacity: 64 x connections per node|64 x fieldbus nodes on master
  • Connection type: 4-pin male connector (fieldbus)|spring CAGE CLAMP (pwr. suppl. connections)|4-pin male connector (device configuration)
  • Mounting mode: DIN-35 rail
  • Speed: 156kbit/s-10Mbit/s
  • Dimensions: H100mm x W61.5mm x D71.9mm
  • Net Width (mm): 61.5mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Ambient air temperature for storage: -25°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Shock resistance according to EN 60068-2-27 --15g
  • Current consumption: 600mA (24Vdc; at nominal load)|200mA (5Vdc; system supply)|1800mA (system supply)
  • Customs Tariff Number: 85176200000
  • eClass code: 27-24-26-07
  • ETIM code: EC001603
  • Order code / Manufacturer SKU: 750-325
  • Manufacturer product status: Commercialized
  • Equivalent to: 750325
  • EAN code: 4055143597449
  • Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-4|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-FBC750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- KTL - Korea Testing Laboratory - KOSHA Article 34 / IEC60079-0 - certificate 23-KA4BO-0698X|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Fieldbus coupler / head (remote I/O (RIO) controller unit) - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85176200000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-24-26-07
  • eCl@ss 9.0: 27-24-26-07
  • ETIM 8.0: EC001603
  • ETIM 9.0: EC001603
  • Packaging type: Box
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: communication/fieldbus: CC-Link: 1 x Male connector; 4-pole
  • Connection technology: device configuration: 1 x Male connector; 4-pole
  • Connection technology: field supply: 6 x CAGE CLAMP®
  • Connection technology: system supply: 2 x CAGE CLAMP®
  • Connection type 1: System/field supply
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|693-98-1|7439-92-1|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|2-methylimidazole|Diboron trioxide|Lead|Lead monoxide
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): b72ae42b-6d26-42c7-bbff-c71c15bcf27c
  • SCIP notification number (Belgium): 7e8d85b0-dec6-4d47-8a1d-b4a890d14264
  • SCIP notification number (Bulgaria): ca7cf964-5a30-4608-adbc-f4870b7b7cd0
  • SCIP notification number (Czech Republic): fc6bb315-da69-4841-931e-d5e541f98ead
  • SCIP notification number (Denmark): 1081514b-8d27-433d-9b77-039036d02acd
  • SCIP notification number (Finland): df2d9e9e-9e3f-4e37-913b-de80b3b8b08c
  • SCIP notification number (France): 9dc24a20-f78a-466b-9d7d-2a9753c511b3
  • SCIP notification number (Germany): cb8f348d-9c8c-443d-b168-c0c698e05ffb
  • SCIP notification number (Hungary): d8c1ecbf-42b6-48e2-8e71-7278dc922e60
  • SCIP notification number (Italy): 0c93aa3b-d946-4f68-a69a-33dad2dfe3f0
  • SCIP notification number (Netherlands): f1122e45-401e-423b-90a3-41dc871b2757
  • SCIP notification number (Poland): f11c1f18-8098-4419-b3a1-0263f800e0b5
  • SCIP notification number (Romania): 5da268e2-f35a-4cbc-88be-71d4cd060d5a
  • SCIP notification number (Sweden): 74758c2a-a6f8-493d-93c1-9a89aabd2180

Environmental requirements

  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -25 … +85 °C
  • EMC emission of interference: per EN 61000-6-4
  • EMC immunity to interference: per EN 61000-6-2
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
  • Operating altitude: 0 … 2000 m / 0 … 6562 ft
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (without condensation): 95%
  • Shock resistance: 15g per IEC 60068-2-27
  • Vibration resistance: per IEC 60068-2-6

Material data

  • Conformity marking: CE
  • Fire load: 2.586MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 148.5g

Mechanical data

  • Mounting type: DIN-35 rail

Physical data

  • Depth: 71.9 mm / 2.831 inches
  • Depth from upper-edge of DIN-rail: 64.7 mm / 2.547 inches
  • Height: 100 mm / 3.937 inches
  • Width: 61.5 mm / 2.421 inches

Technical data

  • Bus segment length (max.): 1200 m
  • Communications: CC-Link
  • Current carrying capacity (power jumper contacts): 10A
  • Current consumption (5 V system supply): 200mA
  • Device-specific: Operating mode: CC-Link V2.0 (default setting)/V1.1; Advanced cycle setting: 1, 2, 4 (default setting), 8 cycles
  • Input current (typ.) at nominal load (24 V): 600mA
  • Input process image (note): RX (digital inputs): V1.1: 16, 48, 80, 112 bits; V2.0: 16, 48, 80, 112 bits (1 cycle); V2.0: 16, 80, 144, 208 bits (2 cycles); V2.0: 48, 176, 304, 432 bits (4 cycles); V2.0: 112, 368, 624, 880 bits (8 cycles) and 16 bits per system area; RWr (analog inputs): V1.1: 4, 8, 12, 16 words (16 bits); V2.0: 4, 8, 12, 16 words (1 cycle); V2.0: 8, 16, 24, 32 words (2 cycles); V2.0: 16, 32, 48, 64 words (4 cycles); V2.0: 32, 64, 96, 128 words (8 cycles)
  • Isolation: 500 V system/field
  • Number of fieldbus nodes on master (max.): 64
  • Number of modules per node (max.): 64
  • Number of modules without a bus extension (max.): 64
  • Number of outgoing power jumper contacts: 3
  • Output process image (note): RY (digital outputs): V1.1: 16, 48, 80, 112 bits; V2.0: 16, 48, 80, 112 bits (1 cycle); V2.0: 16, 80, 144, 208 bits (2 cycles); V2.0: 48, 176, 304, 432 bits (4 cycles); V2.0: 112, 368, 624, 880 bits (8 cycles) and 16 bits per system area; RWw (analog outputs): V1.1: 4, 8, 12, 16 words (16 bits); V2.0: 4, 8, 12, 16 words (1 cycle); V2.0: 8, 16, 24, 32 words (2 cycles); V2.0: 16, 32, 48, 64 words (4 cycles); V2.0: 32, 64, 96, 128 words (8 cycles)
  • Power supply efficiency (typ.) at nominal load (24 V): 90%
  • Station addresses: 1 … 4 / 4 (default setting)
  • Supply voltage (field): 24 VDC (-25 … +30 %); via power jumper contacts
  • Supply voltage (system): 24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)
  • Total current (system supply): 1,800mA
  • Transmission medium (communication/fieldbus): Shielded Cu cable 2 / 3 x 0.5 mm²
  • Transmission rate: 156 kBd … 10 MBd