Wago - 2616-3352

$7.92
Sale price  $7.92 Regular price 

Wago - 2616-3352

$7.92
Sale price  $7.92 Regular price 

WAGO component - equivalent to 26163352

Specifications

  • Primary brand: WAGO
  • GTIN code: 4055143860529
  • Order code / Manufacturer SKU: 2616-3352
  • Manufacturer product status: Commercialized
  • Equivalent to: 26163352
  • EAN code: 4055143860529
  • Manufacturer description: PCB terminal block; lever; 16mm2; Pin spacing 15mm; 2-pole; Push-in CAGE CLAMP; 16mm2; gray
  • Manufacturer product specifications: Electrical data - Ratings per IEC/EN - Ratings per -- IEC/EN 60664-1|Electrical data - Ratings per IEC/EN - Nominal voltage (III/3) -- 800V|Electrical data - Ratings per IEC/EN - Rated impulse withstand voltage (III / 3) -- 8kV|Electrical data - Ratings per IEC/EN - Rated voltage (III/2) -- 1000V|Electrical data - Ratings per IEC/EN - Rated impulse withstand voltage (III/2) -- 8kV|Electrical data - Ratings per IEC/EN - Nominal voltage (II/2) -- 1000V|Electrical data - Ratings per IEC/EN - Rated impulse withstand voltage (II/2) -- 8kV|Electrical data - Ratings per IEC/EN - Rated current -- 76A|Electrical data - Ratings per IEC/EN - Legend (ratings) -- (III / 2) Overvoltage category III / Pollution degree 2|Electrical data - Ratings per UL - Approvals per -- UL 1059|Electrical data - Ratings per UL - Rated voltage UL (Use Group B) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group B) -- 66A|Electrical data - Ratings per UL - Rated voltage UL (Use Group C) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group C) -- 66A|Electrical data - Ratings per UL - Rated voltage UL (Use Group D) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group D) -- 66A|Electrical data - Ratings per CSA - Approvals per -- CSA|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group B) -- 300V|Electrical data - Ratings per CSA - Rated current CSA (Use Group B) -- 72A|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group C) -- 300V|Electrical data - Ratings per CSA - Rated current CSA (Use Group C) -- 72A|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group D) -- 600V|Electrical data - Ratings per CSA - Rated current CSA (Use Group D) -- 72A|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Number of connection types -- 1|Connection data - Number of levels -- 1|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Lever|Connection data - Connection 1 - Solid conductor -- 0.75...16mm2 / 18...4 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.75...25mm2 / 18...4 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.75...16mm2|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.75...16mm2|Connection data - Connection 1 - Fine-stranded conductor; with twin ferrule -- 0.75...6mm2|Connection data - Connection 1 - Strip length -- 18...20mm / 0.71...0.79"|Connection data - Connection 1 - Conductor connection direction to PCB -- 90°|Connection data - Connection 1 - Pole number -- 2|Physical data - Pin spacing -- 15mm / 0.591"|Physical data - Width -- 26.5mm / 1.043"|Physical data - Height -- 38.2mm / 1.504"|Physical data - Height from the surface -- 34.2mm / 1.346"|Physical data - Depth -- 29.4mm / 1.157"|Physical data - Solder pin length -- 4mm|Physical data - Solder pin dimensions -- 1.2 x 1.2mm|Physical data - Drilled hole diameter with tolerance -- 1.7 (+0.1)mm|PCB contact - PCB contact -- THT|PCB contact - Solder pin arrangement -- Over the entire terminal strip (in-line)|PCB contact - Number of solder pins per potential -- 6|Material data - Color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Electrolytic Copper (ECu)|Material data - Contact plating -- Tin|Material data - Fire load -- 0.338MJ|Material data - Actuator color -- orange|Material data - Weight -- 21.6g|Environmental requirements - Limit temperature range -- -60...+105°C|Environmental requirements - Processing temperature -- -35...+60°C|Environmental requirements - Environmental Testing (Environmental Conditions) - Test specification / Railway applications - / Rolling stock - / Electronic equipment -- DIN EN 50155 (VDE 0115-200)2022-06|Environmental requirements - Environmental Testing (Environmental Conditions) - Test procedure / Railway applications - / Rolling stock equipment - / Shock and vibration tests -- DIN EN 61373 (VDE 0115-0106)2011-04|Environmental requirements - Environmental Testing (Environmental Conditions) - Spectrum/Installation location -- Service life test; Category 1; Class A/B|Environmental requirements - Environmental Testing (Environmental Conditions) - Function test with noise-like vibration -- Test passed according to Section 8 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Frequency -- f1 = 5Hz to f2 = 150Hz|Environmental requirements - Environmental Testing (Environmental Conditions) - Acceleration -- 0.101g (highest test level used for all axes) / 0.572g (highest test level used for all axes) / 5g (highest test level used for all axes)|Environmental requirements - Environmental Testing (Environmental Conditions) - Test duration per axis -- 10 min. / 5 h|Environmental requirements - Environmental Testing (Environmental Conditions) - Test directions -- X; Y and Z axes|Environmental requirements - Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration -- Test passed according to Section 9 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Monitoring for contact faults/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock test -- Test passed according to Section 10 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock form -- Half sine|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock duration -- 30ms|Environmental requirements - Environmental Testing (Environmental Conditions) - Number of shocks per axis -- 3 pos. und 3 neg.|Environmental requirements - Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment -- Passed|Commercial data - ETIM 9.0 -- EC002643|Commercial data - ETIM 8.0 -- EC002643|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 44 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- DE|Commercial data - GTIN -- 4055143860529|Commercial data - Customs tariff number -- 85369010000|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption
  • Location of origin: Germany
  • Level 1 category: Electrical components

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85369010000
  • ECCN: NO US CLASSIFICATION
  • ETIM 8.0: EC002643
  • ETIM 9.0: EC002643
  • GTIN: 4055143860529
  • Packaging type: box
  • PU (SPU): 44 pcs

Connection data

  • Clamping units: 2
  • Connection 1 - Actuation type: Lever
  • Connection 1 - Conductor connection direction to PCB: 90°
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.75 … 25 mm² / 18 … 4 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.75 … 16 mm²
  • Connection 1 - Fine-stranded conductor; with twin ferrule: 0.75 … 6 mm²
  • Connection 1 - Fine-stranded conductor; with uninsulated ferrule: 0.75 … 16 mm²
  • Connection 1 - Pole number: 2
  • Connection 1 - Solid conductor: 0.75 … 16 mm² / 18 … 4 AWG
  • Connection 1 - Strip length: 18 … 20 mm / 0.71 … 0.79 inches
  • Number of connection types: 1
  • Number of levels: 1
  • Total number of potentials: 2

Electrical data

  • Ratings per CSA - Approvals per: CSA
  • Ratings per CSA - Rated current CSA (Use Group B): 72A
  • Ratings per CSA - Rated current CSA (Use Group C): 72A
  • Ratings per CSA - Rated current CSA (Use Group D): 72A
  • Ratings per CSA - Rated voltage CSA (Use Group B): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group C): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group D): 600V
  • Ratings per IEC/EN - Legend (ratings): (III / 2) ≙ Overvoltage category III / Pollution degree 2
  • Ratings per IEC/EN - Nominal voltage (II/2): 1000V
  • Ratings per IEC/EN - Nominal voltage (III/3): 800V
  • Ratings per IEC/EN - Rated current: 76A
  • Ratings per IEC/EN - Rated impulse withstand voltage (II/2): 8kV
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 8kV
  • Ratings per IEC/EN - Rated impulse withstand voltage (III/2): 8kV
  • Ratings per IEC/EN - Rated voltage (III/2): 1000V
  • Ratings per IEC/EN - Ratings per: IEC/EN 60664-1
  • Ratings per UL - Approvals per: UL 1059
  • Ratings per UL - Rated current UL (Use Group B): 66A
  • Ratings per UL - Rated current UL (Use Group C): 66A
  • Ratings per UL - Rated current UL (Use Group D): 66A
  • Ratings per UL - Rated voltage UL (Use Group B): 600V
  • Ratings per UL - Rated voltage UL (Use Group C): 600V
  • Ratings per UL - Rated voltage UL (Use Group D): 600V

Environmental Product Compliance

  • RoHS Compliance Status: Compliant,No Exemption

Environmental requirements

  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
  • Limit temperature range: -60 … +105 °C
  • Processing temperature: -35 … +60 °C

Material data

  • Actuator color: orange
  • Clamping spring material: Chrome-nickel spring steel (CrNi)
  • Color: gray
  • Contact material: Electrolytic copper (ECu)
  • Contact plating: Tin
  • Fire load: 0.338MJ
  • Flammability class per UL94: V0
  • Insulation material (main housing): Polyamide (PA66)
  • Material group: I
  • Note (material data):
    Information on material specifications can be found here
  • Weight: 21.6g

Notes

  • Variants:: Other pole numbers|Direct marking|Other colors|Other versions (or variants) can be requested from WAGO Sales or configured at https://configurator.wago.com/.

PCB contact

  • Number of solder pins per potential: 6
  • PCB contact: THT
  • Solder pin arrangement: Over the entire terminal strip (in-line)

Physical data

  • Depth: 29.4 mm / 1.157 inches
  • Drilled hole diameter with tolerance: 1.7 (+0.1) mm
  • Height: 38.2 mm / 1.504 inches
  • Height from the surface: 34.2 mm / 1.346 inches
  • Pin spacing: 15 mm / 0.591 inches
  • Solder pin dimensions: 1.2 x 1.2 mm
  • Solder pin length: 4mm
  • Width: 26.5 mm / 1.043 inches

You may also like