Neutral-through terminal block with 1-deck/level + btn. + side/lateral and center marking slots - Suitable for Ex e II / Ex I applications - with test port - WAGO (2206 TOPJOB S series) - Blue - Neutral-through pole (N) / 3-wires (1 push-in + 2 push-in) (1+2) - 6mm2 nominal cross-section - for 0.5mm2...10mm2 / for #20AWG...#8AWG - Rated current 41A / 57A - with Push-in CAGE CLAMP spring connections - DIN-35 rail (35 x 15 / 35 x 7.5) mounting (7.5mm width) - equivalent to 22061304

Specifications

  • Primary brand: WAGO
  • Functions: Neutral-through terminal block
  • Design: 1-deck/level|btn.|side/lateral and center marking slots|2 jumper slots|Suitable for Ex e II / Ex I applications|with test port
  • Poles: Neutral-through pole (N)
  • Temperature: Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C
  • Rated current: (IEC) 41A|(IEC) 57A|(UL) 50A|(CSA) 50A|(Ex e II) 41A|(Ex e II with jumper) 33A
  • Color: Blue|Orange actuator
  • Connection capacity: 3-wires (1 push-in + 2 push-in) (1+2)
  • Rated operating voltage (Ue): (IEC) 800V|(UL) 600V|(CSA) 600V|(Ex e II) 550V
  • Rated impulse voltage (Uimp): (IEC) 8kV
  • Connection type: Push-in CAGE CLAMP spring connections
  • Cross-section: for 0.5mm2...10mm2 fine stranded or solid conductors|for 0.5mm2...6mm2 fine stranded conductors with insulated ferrule|for 1.5mm2 fine stranded conductors with ferrule; push-in termination|for 1mm2...10mm2 solid conductors; push-in termination|for #20AWG...#8AWG fine stranded or solid conductors|for #20AWG...#10AWG fine stranded conductors with insulated ferrule|for #16AWG fine stranded conductors with ferrule; push-in termination|for #14AWG...#8AWG solid conductors; push-in termination|6mm2 nominal cross-section
  • Mounting mode: DIN-35 rail (35 x 15 / 35 x 7.5)
  • Dimensions: H73.3mm x W7.5mm x D39.5mm
  • Net Width (mm): 7.5mm
  • Material: Polyamide (PA) 66
  • eClass code: 27-14-11-20
  • ETIM code: EC000897
  • GTIN code: 4055143712101
  • Customs Tariff Number: 85369010000
  • Order code / Manufacturer SKU: 2206-1304
  • Manufacturer product status: Commercialized
  • Equivalent to: 22061304
  • EAN code: 4055143712101
  • Compliant with standard(s): General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL-7957|- CSA - CSA Group - C22.2 - certificate 70175034|- KEMA/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-125861|- UL - Underwriters Laboratories Inc. - C22.2 No. 158 - certificate E45172|Declarations of conformity and manufacturer's declarations|- ATEX-Attestation of Conformity - WAGO GmbH & Co. KG|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- Railway - WAGO GmbH & Co. KG - certificate Z00004406.000|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 19-HG1866350-PDA|- BV - Bureau Veritas S.A. - IEC 60947 - certificate 58186/A0 BV|- DNV GL - Det Norske Veritas Germanischer Lloyd - certificate TAE00003JT|- LR - Lloyds Register - certificate 19/20050|Approvals for hazardous areas|- AEx - Underwriters Laboratories Inc. - UL 60079 - certificate E 185892 (AEx eb IIC / Ex eb IIC)|- ATEX - Physikalisch Technische Bundesanstalt - IEC 60079-0 - certificate PTB 18 ATEX 1007 U (II 2 Ex eb IIC Gb bzw. I M 2 Ex eb I Mb)|- CCC - CNEX - GB/T 3836.3 - certificate 2020312313000171 (Ex eb IIC Gb / Ex eb I Mb)|- IECEx - Physikalisch Technische Bundesanstalt - IEC 60079 - certificate IECEx PTB 18.0014U (Ex eb IIC Gb and Ex eb I Mb)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079 - certificate TUV 19.0087 U|RoHS compliant|material group I|V-0 flammability rating
  • Location of origin: Germany
  • Level 1 category: Electrical components
  • Level 2 category: Terminal blocks
  • Product title: Neutral-through terminal block - 1-deck/level - WAGO (TOPJOB S series)

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85369010000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-20
  • eCl@ss 9.0: 27-14-11-20
  • ETIM 8.0: EC000897
  • ETIM 9.0: EC000897
  • GTIN: 4055143712101
  • Packaging type: box
  • PU (SPU): 25 pcs

Connection data

  • Clamping units: 3
  • Connection 1 - Actuation type: Push-button
  • Connection 1 - Connectable conductor materials: Copper
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.5 … 10 mm² / 20 … 8 AWG
  • Connection 1 - Fine-stranded conductor; with ferrule; push-in termination: 1.5 mm² / 16 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.5 … 6 mm² / 20 … 10 AWG
  • Connection 1 - Nominal cross-section: 6 mm²
  • Connection 1 - Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 - Solid conductor: 0.5 … 10 mm² / 20 … 8 AWG
  • Connection 1 - Solid conductor; push-in termination: 1 … 10 mm² / 14 … 8 AWG
  • Connection 1 - Strip length: 13 … 15 mm / 0.51 … 0.59 inches
  • Connection 1 - Wiring direction: Front-entry wiring
  • Number of jumper slots: 2
  • Number of levels: 1
  • Total number of potentials: 1

Electrical data

  • Ex information - Rated current (Ex e II): 41A
  • Ex information - Rated current (Ex e II) with jumper: 33A
  • Ex information - Rated voltage EN (Ex e II): 550V
  • Ex information - Ratings per: ATEX: PTB 18 ATEX 1007 U / IECEx: PTB 18.0014U
  • Ex information - Reference hazardous areas: See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
  • Power Loss - Power loss, per pole (potential): 0.799W
  • Power Loss - Rated current IN for specified power loss: 41A
  • Power Loss - Resistance value for specified, current-dependent power loss: 0.001Ω
  • Ratings per CSA - Approvals per: CSA 22.2 No 158
  • Ratings per CSA - Rated current CSA (Use Group B): 50A
  • Ratings per CSA - Rated current CSA (Use Group C): 50A
  • Ratings per CSA - Rated voltage CSA (Use Group B): 600V
  • Ratings per CSA - Rated voltage CSA (Use Group C): 600V
  • Ratings per IEC/EN - Current at conductor cross-section (max.) mm²: 57A
  • Ratings per IEC/EN - Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • Ratings per IEC/EN - Nominal voltage (III/3): 800V
  • Ratings per IEC/EN - Rated current: 41A
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 8kV
  • Ratings per IEC/EN - Ratings per: IEC/EN 60947-7-1
  • Ratings per UL - Approvals per: UL 1059
  • Ratings per UL - Rated current UL (Use Group B): 50A
  • Ratings per UL - Rated current UL (Use Group C): 50A
  • Ratings per UL - Rated voltage UL (Use Group B): 600V
  • Ratings per UL - Rated voltage UL (Use Group C): 600V

Environmental Product Compliance

  • RoHS Compliance Status: Compliant,No Exemption

Environmental requirements

  • Continuous operating temperature: -60 … +105 °C
  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
  • Processing temperature: -35 … +85 °C

Material data

Mechanical data

  • Marking level: Center/side marking
  • Mounting type: DIN-35 rail

Physical data

  • Depth: 39.5 mm / 1.555 inches
  • Depth from upper-edge of DIN-rail: 32.9 mm / 1.295 inches
  • Height: 73.3 mm / 2.886 inches
  • Width: 7.5 mm / 0.295 inches