Wago - 2020-1401

$3.03
Sale price  $3.03 Regular price 

Wago - 2020-1401

$3.03
Sale price  $3.03 Regular price 

Carrier feed-through/thru terminal block with 1-deck/level + side/lateral and center marking slots - WAGO (2020 X-COM S-Mini series) - Gray - 1 feed-through pole (1P) / 4-wires (2 push-in + 2 plug-in pins) (2+2) - 1mm2 nominal cross-section - for 0.14mm2...1.5mm2 / for #24AWG...#16AWG - Rated current 13.5A - with Push-in CAGE CLAMP spring connections + Plug-in pin connections - DIN-35 rail (35 x 15 / 35 x 7.5) mounting (3.5mm width) - equivalent to 20201401

Specifications

  • Primary brand: WAGO
  • Functions: Carrier feed-through/thru terminal block
  • Design: 1-deck/level|side/lateral and center marking slots
  • Poles: 1 feed-through pole (1P)
  • Temperature: Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C
  • Rated current: (IEC) 13.5A|(UL) 15A|(CSA) 10A
  • Color: Gray
  • Connection capacity: 4-wires (2 push-in + 2 plug-in pins) (2+2)
  • Rated operating voltage (Ue): (IEC) 500V|(UL) 300V|(CSA) 300V
  • Rated impulse voltage (Uimp): (IEC) 6kV
  • Connection type: Push-in CAGE CLAMP spring connections|Plug-in pin connections
  • Cross-section: for 0.14mm2...1.5mm2 fine stranded or solid conductors|for 0.14mm2...0.75mm2 fine stranded conductors with insulated ferrule|for 0.5mm2...0.75mm2 fine stranded conductors with ferrule; push-in termination|for 0.5mm2...1.5mm2 solid conductors; push-in termination|for #24AWG...#16AWG fine stranded or solid conductors|for #24AWG...#18AWG fine stranded conductors with insulated ferrule|for #20AWG...#18AWG fine stranded conductors with ferrule; push-in termination|for #20AWG...#16AWG solid conductors; push-in termination|1mm2 nominal cross-section
  • Mounting mode: DIN-35 rail (35 x 15 / 35 x 7.5)
  • Dimensions: H86.2mm x W3.5mm x D36.4mm
  • Net Width (mm): 3.5mm
  • Material: Polyamide (PA) 66
  • eClass code: 27-14-11-20
  • Customs Tariff Number: 85366990990
  • GTIN code: 4050821145301
  • ETIM code: EC000897
  • Order code / Manufacturer SKU: 2020-1401
  • Manufacturer product status: Commercialized
  • Equivalent to: 20201401
  • EAN code: 4050821145301
  • Compliant with standard(s): General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL 7617|- CSA - DEKRA Certification B.V. - C22.2 - certificate 2516073|- KEMA/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-100670|- UL - UL International Germany GmbH - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- Railway - WAGO GmbH & Co. KG - certificate Z00004390.000|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - EN 60947 - certificate 20-HG1941090-PDA|- BV - Bureau Veritas S.A. - EN 60947 - certificate 38586/B0 BV|- DNV GL - Det Norske Veritas Germanischer Lloyd - certificate TAE00001V2|- LR - Lloyds Register - EN 60947 - certificate 91/20112 (E9)|RoHS compliant|material group I|V-0 flammability rating
  • Location of origin: China
  • Level 1 category: Electrical components
  • Level 2 category: Terminal blocks
  • Product title: Carrier feed-through/thru terminal block - 1-deck/level - WAGO (X-COM S-Mini series)

Commercial data

  • Country of origin: CN
  • Customs tariff number: 85366990990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-20
  • eCl@ss 9.0: 27-14-11-20
  • ETIM 8.0: EC000897
  • ETIM 9.0: EC000897
  • GTIN: 4050821145301
  • Packaging type: Box
  • Product Group: 18 (X-COM-System)
  • PU (SPU): 50 pcs

Connection data

  • Clamping units: 2
  • Connection 1 - Actuation type: Operating tool
  • Connection 1 - Connectable conductor materials: Copper
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.14 … 1.5 mm² / 24 … 16 AWG
  • Connection 1 - Fine-stranded conductor; with ferrule; push-in termination: 0.5 … 0.75 mm² / 20 … 18 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.14 … 0.75 mm² / 24 … 18 AWG
  • Connection 1 - Nominal cross-section: 1 mm²
  • Connection 1 - Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 - Solid conductor: 0.14 … 1.5 mm² / 24 … 16 AWG
  • Connection 1 - Solid conductor; push-in termination: 0.5 … 1.5 mm² / 20 … 16 AWG
  • Connection 1 - Strip length: 9 … 11 mm / 0.35 … 0.43 inches
  • Connection 1 - Wiring direction: Front-entry wiring
  • Female plug slots: 2
  • Number of levels: 1
  • Total number of potentials: 1

Electrical data

  • Power Loss - Power loss, per pole (potential): 0.434W
  • Power Loss - Rated current IN for specified power loss: 13.5A
  • Power Loss - Resistance value for specified, current-dependent power loss: 0.002Ω
  • Ratings per CSA - Approvals per: CSA 22.2 No 158
  • Ratings per CSA - Rated current CSA (Use Group B): 10A
  • Ratings per CSA - Rated current CSA (Use Group C): 10A
  • Ratings per CSA - Rated current CSA (Use Group D): 10A
  • Ratings per CSA - Rated voltage CSA (Use Group B): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group C): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group D): 300V
  • Ratings per IEC/EN - Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • Ratings per IEC/EN - Nominal voltage (III/3): 500V
  • Ratings per IEC/EN - Rated current: 13.5A
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 6kV
  • Ratings per IEC/EN - Ratings per: IEC/EN 60947-7-1
  • Ratings per UL - Approvals per: UL 1059
  • Ratings per UL - Rated current UL (Use Group B): 15A
  • Ratings per UL - Rated current UL (Use Group C): 15A
  • Ratings per UL - Rated current UL (Use Group D): 15A
  • Ratings per UL - Rated voltage UL (Use Group B): 300V
  • Ratings per UL - Rated voltage UL (Use Group C): 300V
  • Ratings per UL - Rated voltage UL (Use Group D): 300V

Environmental Product Compliance

  • RoHS Compliance Status: Compliant,No Exemption

Environmental requirements

  • Continuous operating temperature: -60 … +105 °C
  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
  • Processing temperature: -35 … +85 °C

Material data

Mechanical data

  • Design: horizontal type
  • Marking level: Center/side marking
  • Mounting type: DIN-35 rail

Notes

  • Safety Information: A separator plate (Item No. 209-191) or a 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM®-SYSTEM terminal strip.

Physical data

  • Depth from upper-edge of DIN-rail: 36.4 mm / 1.433 inches
  • Height: 86.2 mm / 3.394 inches
  • Width: 3.5 mm / 0.138 inches

You may also like