Wago - 2000-556

$24.11
Sale price  $24.11 Regular price 

Wago - 2000-556

$24.11
Sale price  $24.11 Regular price 

Modular connector for jumper contact slot - WAGO (2000 TOPJOB S series) - 6-poles (6P) - 1mm2 nominal cross-section - for 0.14mm2...1.5mm2 / for #24AWG...#16AWG - Rated current 13.5A - Gray color - with Push-in CAGE CLAMP spring connections - Plug-in mounting - equivalent to 2000556

Specifications

  • Primary brand: WAGO
  • Functions: Modular connector for jumper contact slot
  • Poles: 6-poles (6P)
  • Rated current: 13.5A
  • Color: Gray
  • Rated operating voltage (Ue): (IEC) 500V
  • Rated impulse voltage (Uimp): (IEC) 6kV
  • Connection type: Push-in CAGE CLAMP spring connections
  • Cross-section: for 0.14mm2...1.5mm2 fine stranded or solid conductors|for #24AWG...#16AWG fine stranded or solid conductors|1mm2 nominal cross-section
  • Mounting mode: Plug-in
  • Dimensions: W22.5mm
  • Material: Polyamide (PA) 66
  • Customs Tariff Number: 85366990990
  • GTIN code: 4055143394666
  • eClass code: 27-14-11-51
  • ETIM code: EC002021
  • Order code / Manufacturer SKU: 2000-556
  • Manufacturer product status: Commercialized
  • Equivalent to: 2000556
  • EAN code: 4055143394666
  • Compliant with standard(s): General approvals|- CSA - DEKRA Certification B.V. - C22.2 - certificate 2130762|Declarations of conformity and manufacturer's declarations|- Railway - WAGO GmbH & Co. KG - certificate Railway Ready|RoHS compliant|V-0 flammability rating
  • Location of origin: Germany
  • Level 1 category: Cabling systems
  • Level 2 category: Connectors & Inserts
  • Product title: Modular connector for jumper contact slot - WAGO (TOPJOB S series)

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85366990990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-51
  • eCl@ss 9.0: 27-14-11-51
  • ETIM 8.0: EC002021
  • ETIM 9.0: EC002021
  • GTIN: 4055143394666
  • Packaging type: box
  • PU (SPU): 10 pcs

Connection data

  • Clamping units: 6
  • Connection 1 - Actuation type: Operating tool
  • Connection 1 - Connectable conductor materials: Copper
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.14 … 1.5 mm² / 24 … 16 AWG
  • Connection 1 - Fine-stranded conductor; with ferrule; push-in termination: 0.5 … 0.75 mm² / 20 … 18 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.14 … 0.75 mm² / 24 … 18 AWG
  • Connection 1 - Nominal cross-section: 1 mm²
  • Connection 1 - Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 - Pole number: 6
  • Connection 1 - Solid conductor: 0.14 … 1.5 mm² / 24 … 16 AWG
  • Connection 1 - Solid conductor; push-in termination: 0.5 … 1.5 mm² / 20 … 16 AWG
  • Connection 1 - Strip length: 9 … 11 mm / 0.35 … 0.43 inches
  • Connection 1 - Wiring direction: Side-entry wiring
  • Total number of potentials: 6

Electrical data

  • Ratings per CSA - Approvals per: CSA 22.2 No 158
  • Ratings per CSA - Rated current CSA (Use Group B): 10A
  • Ratings per CSA - Rated current CSA (Use Group C): 10A
  • Ratings per CSA - Rated voltage CSA (Use Group B): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group C): 300V
  • Ratings per IEC/EN - Nominal voltage (III/3): 500V
  • Ratings per IEC/EN - Rated current: 13.5A
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 6kV
  • Ratings per UL - Rated current UL (Use Group B): 10A
  • Ratings per UL - Rated current UL (Use Group C): 10A
  • Ratings per UL - Rated voltage UL (Use Group B): 300V
  • Ratings per UL - Rated voltage UL (Use Group C): 300V

Environmental Product Compliance

  • RoHS Compliance Status: Compliant,No Exemption

Environmental requirements

  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed

Material data

Mechanical data

  • Marking level: Center/side marking

Notes

  • Safety Information: According to EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.

Physical data

  • Module width: 3.5 mm / 0.138 inches
  • Width: 22.5 mm / 0.885 inches