{"product_id":"wago-859-736","title":"Wago - 859-731","description":"\u003cp\u003eFixed-type solid-state \/ static relay (SSR) with red LED - 2-wire connection - WAGO (859 series) - 2-channels \/ 2-poles \/ 2-phases (2P) - control voltage 100-120Vdc (110Vdc nom.) - Rated voltage 3Vdc-30Vdc (24Vdc nom.) output - Rated current 3A (continuous) - with CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - equivalent to 859731\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Fixed-type solid-state \/ static relay (SSR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e red LED|2-wire connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 2-channels \/ 2-poles \/ 2-phases (2P)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 70Hz switching frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -25°C...+50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 3A (continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (DC):\u003c\/strong\u003e 3Vdc-30Vdc (24Vdc nom.) output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage (DC):\u003c\/strong\u003e 100-120Vdc (110Vdc nom.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e (switching ON) 500μs \/ 0.0005s|(switching OFF) 6ms \/ 0.006s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H91mm x W6mm x D56mm|6mm width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polyamide (PA) 66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -25°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85365005000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001504\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143605021\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 859-731\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 859731\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143605021\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- II|EN 61000-6-2|EN 61000-6-3|EN 61010-2-201|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03078|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|RoHS compliant with exemption (7(a) \/ 7(c)-I)|material group I|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Control components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Control relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Fixed-type solid-state \/ static relay (SSR) - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85365005000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001504\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001504\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143605021\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.08 … 1.5 mm² \/ 28 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.2 … 1.5 mm² \/ 24 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 5 … 6 mm \/ 0.2 … 0.24 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 7(a)|7(c)-I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 5e21fa6e-4eb4-463c-b3fa-78ec7eebd581\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e bb1fb17a-0c98-4aaa-94b6-800d3096f94b\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e fe949cf6-01d5-4087-b60b-f5f657477a5a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 39d7c6a2-4c0b-4efc-bc08-a0d116cbdea3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 37a2b05c-9d2e-4762-9938-55a58a3ef514\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e f26cfeeb-9d9d-4aea-a4a0-f6ffe8557ee4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 559dc5c8-d81f-4a8b-bb66-bcd1063c5db9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 042212ee-9d85-44b7-8f97-9e345dbb3977\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 5c17722c-971a-4f7f-a826-54fbb43917a9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 3aaffb28-deca-4738-9db7-f85cfa19c532\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 7c7deded-e352-46c8-9186-9c63d050fde3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 4a1270c5-f66f-4ca2-8586-1db58a175c34\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 2c8b78c6-0060-460e-b307-4be8f71cf2d7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 3eef45f4-2317-4f44-a218-5c2ce339e2ce\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -25 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature UL (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -25 … +30 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -25 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 95 % (no condensation permissible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 20 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.338MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e horizontal (standing\/lying); vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Optocouplers and solid state relays are designed for use in signal processing networks that are not supplied directly by the low-voltage power supply network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 56 mm \/ 2.205 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 91 mm \/ 3.583 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6 mm \/ 0.236 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (control\/load circuit) (AC, 1 min):\u003c\/strong\u003e 3 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (between adjacent devices of the same type):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (control\/load circuit):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; in connected state or when using 859-525 end plate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 150V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of circuits:\u003c\/strong\u003e Mains circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61010-2-201|EN 61000-6-2|EN 61000-6-3|UL 508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Input voltage range (high level):\u003c\/strong\u003e 100 … 120 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Input voltage range (low level):\u003c\/strong\u003e 0 … 60 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input current at U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 4 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input voltage U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 110 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Circuit type:\u003c\/strong\u003e 2-wire connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Limiting continuous current:\u003c\/strong\u003e 3 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Nominal output voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Output voltage range:\u003c\/strong\u003e 3 … 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Peak output current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching frequency:\u003c\/strong\u003e ≤ 70 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Turn-off time:\u003c\/strong\u003e ≤ 6 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Turn-on time:\u003c\/strong\u003e ≤ 500 µs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Voltage drop:\u003c\/strong\u003e ≤ 0.4 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling - Status indicator:\u003c\/strong\u003e Red LED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695288664201,"sku":"60335619","price":48.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/2000-02000021000306ac000100b6-de_8a8fc5d3-7deb-49a8-b5a7-07fa50b628b5.jpg?v=1786987285","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-859-736","provider":"US Automation Controls","version":"1.0","type":"link"}