Fixed-type solid-state / static relay (SSR) with red LED - 3-wire connection - low-side switching - WAGO (859 series) - single-pole / single-phase / 1-pole (1P) - control voltage 18-30Vdc (24Vdc nom.) - Rated voltage 4Vdc-6.25Vdc (5Vdc nom.) output - Rated current 0.5A (continuous) - with CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - equivalent to 859706

Specifications

  • Primary brand: WAGO
  • Functions: Fixed-type solid-state / static relay (SSR)
  • Design: red LED|3-wire connection|low-side switching
  • Poles: single-pole / single-phase / 1-pole (1P)
  • Frequency: 20kHz switching frequency
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 0.5A (continuous)
  • Rated Voltage (DC): 4Vdc-6.25Vdc (5Vdc nom.) output
  • Connection type: CAGE CLAMP connections
  • Control Voltage (DC): 18-30Vdc (24Vdc nom.)
  • Mounting mode: DIN-35 rail
  • Response time: (switching ON) 3μs / 0.000003s|(switching OFF) 13μs / 0.000013s
  • Dimensions: H91mm x W6mm x D56mm|6mm width
  • Material: Polyamide (PA) 66
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Humidity: 5-95% relative humidity (RH; non-condensing)
  • ETIM code: EC001504
  • eClass code: 27-26-15-03
  • Customs Tariff Number: 85365005000
  • GTIN code: 4055143604697
  • Order code / Manufacturer SKU: 859-706
  • Manufacturer product status: Commercialized
  • Equivalent to: 859706
  • EAN code: 4055143604697
  • Compliant with standard(s): Safety and protection|- Overvoltage category -- II|EN 61000-6-2|EN 61000-6-3|EN 61010-2-201|EN 61373|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Approvals for hazardous areas|- CCC - CNEX - CNCA-C23-01 - certificate 2021312304000982 (Ex ec IIC T4 Gc)|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate WAGO22UKEX007X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - ANSI/ISA 12.12.01 - certificate E198726|RoHS compliant with exemption (7(a) / 7(c)-I)|material group I|V-0 flammability rating
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Fixed-type solid-state / static relay (SSR) - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85365005000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-26-15-03
  • eCl@ss 9.0: 27-26-15-03
  • ETIM 8.0: EC001504
  • ETIM 9.0: EC001504
  • GTIN: 4055143604697
  • Packaging type: Box
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 1 pcs

Connection data

  • Connection technology: CAGE CLAMP®
  • Fine-stranded conductor: 0.14 … 2.5 mm² / 26 … 14 AWG
  • Fine-stranded conductor; with insulated ferrule: 0.14 … 1.5 mm² / 26 … 16 AWG
  • Solid conductor: 0.2 … 2.5 mm² / 24 … 14 AWG
  • Strip length: 5 … 6 mm / 0.2 … 0.24 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1|75980-60-8|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 7(a)|7(c)-I
  • SCIP notification number (Austria): 6318c01b-0a70-48bd-9161-02957a783b8a
  • SCIP notification number (Belgium): 242f89b0-7912-4c88-8d23-7d5ef3f9db8a
  • SCIP notification number (Bulgaria): e5d92170-3ed4-4a81-89fc-aabd25fb0b5f
  • SCIP notification number (Czech Republic): 7b142b70-e95d-4faa-9180-e2653b5062d9
  • SCIP notification number (Denmark): 652efbcb-f729-4ac5-82dd-d78b9ea8cc93
  • SCIP notification number (Finland): 96a0bbb5-85a8-4333-8b2d-0bee0b8ba819
  • SCIP notification number (France): 3075466b-8c94-4f27-a162-17f3bdff67ad
  • SCIP notification number (Germany): a255cf19-b730-42a2-85b9-fc740ce38d35
  • SCIP notification number (Hungary): abfb4596-d432-44d9-8ef4-09bfcce93a7b
  • SCIP notification number (Italy): 0a530d8e-0a15-41ed-9850-8c890a4030d4
  • SCIP notification number (Netherlands): d2a565de-f8c0-4959-9fdb-0e3ba43b9035
  • SCIP notification number (Poland): c89d8b55-d35b-41c3-b023-5db40c0f0f80
  • SCIP notification number (Romania): 54a360b1-b5bd-4de7-86b8-5321289fe7a0
  • SCIP notification number (Sweden): 036ac102-5c42-4e78-843e-5c8217f85582

Environmental requirements

  • Ambient temperature (operation at UN): -40 … +70 °C
  • Ambient temperature (storage): -40 … +85 °C
  • Ambient temperature UL (operation at UN): -40 … +40 °C
  • Operating altitude (max.): 2000m
  • Processing temperature: -25 … +50 °C
  • Relative humidity: 5 … 95 % (no condensation permissible)
  • Temperature range of connection cable: ≥ (Tambient + 20 K)

Material data

Mechanical data

  • Mounting position: horizontal (standing/lying); vertical
  • Mounting type: DIN-35 rail

Notes

  • Note: Optocouplers and solid state relays are designed for use in signal processing networks that are not supplied directly by the low-voltage power supply network.

Physical data

  • Depth from upper-edge of DIN-rail: 56 mm / 2.205 inches
  • Height: 91 mm / 3.583 inches
  • Width: 6 mm / 0.236 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 2.5 kVrms
  • Insulation type (adjacent devices): Reinforced insulation (safe isolation)
  • Insulation type (between adjacent devices of the same type): Reinforced insulation (safe isolation)
  • Insulation type (control/load circuit): Basic insulation
  • Insulation type (to adjacent devices of different types): Basic insulation
  • Overvoltage category: II
  • Pollution degree: 2
  • Protection type: IP20; in connected state or when using 859-525 end plate
  • Rated voltage: 300V

Standards and specifications

  • Standards/specifications: EN 61010-2-201|EN 61000-6-2|EN 61000-6-3|EN 61373|UL 508

Technical data

  • Control circuit - Input voltage range (high level): 16 … 30 VDC
  • Control circuit - Input voltage range (low level): 0 … 10 VDC
  • Control circuit - Nominal input current at UN: 12.3 mA
  • Control circuit - Nominal input voltage UN: 24 VDC
  • Load circuit - Circuit type: 3-wire connection|Low-side switching
  • Load circuit - Leakage current at rated voltage: ≤ 1 µA
  • Load circuit - Limiting continuous current: 0.5 A
  • Load circuit - Nominal output voltage: 5 VDC
  • Load circuit - Output voltage range: 4 … 6.25 VDC
  • Load circuit - Switching frequency: ≤ 20 kHz
  • Load circuit - Turn-off time: ≤ 13 µs
  • Load circuit - Turn-on time: ≤ 3 µs
  • Load circuit - Voltage drop: ≤ 0.8 VDC