{"product_id":"wago-858-325","title":"Wago - 858-324","description":"\u003cp\u003ePlug-in relay assembly with socket base + manual operation + red LED - WAGO (858 series) - 2-poles (2P) - control voltage 19.2-26.4Vdc (24Vdc nom.; 0.8...1.1 x Uc) - 2C\/O \/ DPDT (Double Pole Double Throw) contact - Electromechanical design - Rated current 12A (continuous) \/ 1.5A (250Vac; AC-15) \/ 0.1A (24Vdc; DC-13) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (31mm width) - IP20 - material Silver-Nickel (AgNi) contacts - equivalent to 858324\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Plug-in relay assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e socket base|manual operation|red LED|Electromechanical design|10V \/ 5mA \/ 300mW recommended minimum switching load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 2-poles (2P)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -25°C...+50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 12A (continuous)|1.5A (250Vac; AC-15)|0.1A (24Vdc; DC-13)|24A (4s) AC inrush maximum current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage (AC):\u003c\/strong\u003e 250Vac max. (switching voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage (Uimp):\u003c\/strong\u003e 2.5kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage (DC):\u003c\/strong\u003e 19.2-26.4Vdc (24Vdc nom.; 0.8...1.1 x Uc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e (OFF=\u0026gt;ON \/ contacts closing) 13ms \/ 0.013s|(ON=\u0026gt;OFF \/ contacts opening) 3ms \/ 0.003s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContacts type:\u003c\/strong\u003e 2C\/O \/ DPDT (Double Pole Double Throw) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H97mm x W31mm x D73mm|31mm width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Silver-Nickel (AgNi) contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -40°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-85% relative humidity (RH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical durability (with load):\u003c\/strong\u003e 100 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical durability (at no load):\u003c\/strong\u003e 20 000 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143567732\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 858-324\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 858324\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143567732\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- II|EN 61010-2-201|EN 61810-1|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03084|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Control components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Control relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Plug-in relay assembly - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBasic relay\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWAGO Basic Relay:\u003c\/strong\u003e 858-181\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143567732\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 5 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (conductor cross-section):\u003c\/strong\u003e 2 x 0.34 … 2 x 1.5 mm² \/ 1 x 2.5 mm² \/ 2 x 22 … 2 x 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.34 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -40 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -25 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 85 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 25 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 1.278MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 87.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e horizontal (standing\/lying); vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 73 mm \/ 2.874 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 97 mm \/ 3.819 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 31 mm \/ 1.22 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (control\/load circuit) (AC, 1 min):\u003c\/strong\u003e 2.5 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (load\/load circuit) (AC, 1 min):\u003c\/strong\u003e 2.5 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (open contact) (AC, 1 min):\u003c\/strong\u003e 1.5 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (adjacent devices):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (control\/load circuit):\u003c\/strong\u003e Basic insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (load\/load circuit):\u003c\/strong\u003e Basic insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (open contact):\u003c\/strong\u003e Functional insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse withstand voltage:\u003c\/strong\u003e 2.5kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61010-2-201|EN 61810-1|UL 508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Input voltage range:\u003c\/strong\u003e -20 … +10 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input current at U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 38 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input voltage U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Contact material (relay):\u003c\/strong\u003e AgNi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Drop-out time (typ.):\u003c\/strong\u003e 3ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Electrical life (NO; resistive load; 23 °C):\u003c\/strong\u003e 100 x 10³ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Inrush current (resistive) max.:\u003c\/strong\u003e (AC) 24 A \/ 4 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Limiting continuous current:\u003c\/strong\u003e 12 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Mechanical life:\u003c\/strong\u003e 20 x 10⁶ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Number of changeover\/switchover contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Pull-in time (typ.):\u003c\/strong\u003e 13ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Recommended minimum load:\u003c\/strong\u003e 10 V \/ 5 mA \/ 300 mW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching capacity:\u003c\/strong\u003e AC-15: 1.5 A \/ 240 VAC; DC-13: 0.1 A \/ 250 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching frequency with\/without load (max.):\u003c\/strong\u003e 20 min\u003csup\u003e-1\u003c\/sup\u003e \/ 200 min\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching power (resistive) max.:\u003c\/strong\u003e AC 3000 VA; DC (see load limit curve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching Voltage, Max.:\u003c\/strong\u003e 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling - Status indicator:\u003c\/strong\u003e Red LED|Mechanical\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695508897929,"sku":"60326836","price":35.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000210002f8b5000100b6_de_f5b325c8-04ed-4108-b9da-e3c4e47cb5df.jpg?v=1786989584","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-858-325","provider":"US Automation Controls","version":"1.0","type":"link"}