{"product_id":"wago-857-802","title":"Wago - 857-801","description":"\u003cp\u003eTemperature signal conditioner with DIP switch + interface configuration via software \/ app - WAGO (857 series) - with 1 x analog input (RTD Pt100 \/ Pt200 \/ Pt500 \/ Pt1000 \/ Resistor; 0-1kΩ \/ 0-4.5kΩ; 2-wire \/ 3-wire \/ 4-wire switchable) + 1 x analog output (0-10mA \/ 2-10mA \/ 0-20mA \/ 4-20mA \/ 0-5Vdc \/ 1-5Vdc \/ 0-10Vdc \/ 2-10Vdc) - supply voltage 16.8-31.2Vdc (24Vdc nom.) - with Push-in CAGE CLAMP spring connections - DIN-35 rail mounting (6mm width) - IP20 - rated for -25°C...+70°C ambient - equivalent to 857801\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Temperature signal conditioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e DIP switch|interface configuration via software \/ app\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 16.8-31.2Vdc (24Vdc nom.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 1 x analog input (RTD Pt100 \/ Pt200 \/ Pt500 \/ Pt1000 \/ Resistor; 0-1kΩ \/ 0-4.5kΩ; 2-wire \/ 3-wire \/ 4-wire switchable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog outputs:\u003c\/strong\u003e 1 x analog output (0-10mA \/ 2-10mA \/ 0-20mA \/ 4-20mA \/ 0-5Vdc \/ 1-5Vdc \/ 0-10Vdc \/ 2-10Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H94mm x W6mm x D97.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polyamide (PA) 66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -25°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 50mA (24Vdc; at nominal load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-21-01-29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454502713\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC002919\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 857-801\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 857801\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454502713\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|DNV|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-4|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 40179_B0|- DNV - DNV Germany GmbH - DNV-CG-0339 \/ Aug.2021 - certificate TAA00001D1|Approvals for hazardous areas|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000210 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - certificate IECEX TUN14.0030X|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate WAGO22UKEX004X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - ANSI\/ISA 12.12.01 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Cabling systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Connectors \u0026amp; Inserts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Temperature signal conditioner - DIP switch - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-21-01-29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-20-02-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002919\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002919\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454502713\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e bag\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|75980-60-8|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 05f3f3b8-0a15-4f60-9562-f07c8c9aedb6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 0b91be23-06aa-417e-a8c2-3bf30774ed99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 7315f2b8-26e9-4d3d-8f36-1808cd8e283f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e eb77ace6-81f9-4b92-8742-2e644874c902\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e f4d34c3a-3b7a-45d1-9eb9-453cce66da71\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e c3822dd5-0b0a-4b87-b750-fa5e876de096\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 6a6d3328-7ad1-4ac8-8723-f4ff801e831f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e a6452dd4-84e9-41b3-a6a6-e215c79faa52\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 0ed82f30-ad55-46b1-afef-2972a2c4c660\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 0b6a053f-6481-42ca-9519-aac8e90518f8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e fd93a37a-ab44-41d4-a41c-b1c88afee098\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 3a0e53e4-8b02-490a-aca1-fd8709146416\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 73bbe297-1659-4ff2-aaed-ded4d693e383\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e d037dc84-e2eb-4874-b372-fdf8fc8b8e03\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -25 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 95 % (no condensation permissible)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.363MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 35.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Additional setting options as well as output signal inversion via WAGO Interface Configuration Software|Additional setting options as well as output signal inversion via WAGO Interface Configuration Software or WAGO Interface Configuration App\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 97.8 mm \/ 3.85 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 94 mm \/ 3.701 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6 mm \/ 0.236 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage (input\/output\/supply):\u003c\/strong\u003e 2.5 kVAC; 50 Hz; 1 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e DNV|DNV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration - Configuration options:\u003c\/strong\u003e DIP switch|WAGO Interface Configuration Software|WAGO Interface Configuration App\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal type:\u003c\/strong\u003e Resistance|Pt sensors|Resistor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (resistors) - Input range (resistor):\u003c\/strong\u003e 0 … 1 kΩ; 0 … 4.5 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (resistors) - Measurement span (min.):\u003c\/strong\u003e 50Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Measurement span (RTD) min.:\u003c\/strong\u003e 50K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Sensor connection:\u003c\/strong\u003e 2-wire; 3-wire; 4-wire (switchable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Sensor power supply (RTD) max.:\u003c\/strong\u003e ≤ 0.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Sensor types (RTD):\u003c\/strong\u003e Pt100|Pt200|Pt500|Pt1000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Temperature measurement range (RTD):\u003c\/strong\u003e -200 … +850 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Temperature coefficient:\u003c\/strong\u003e ≤ 0.02 %\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (typ.):\u003c\/strong\u003e ≤ 0.1 % at full measurement span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error for the set measurement range:\u003c\/strong\u003e ≤ ((10 K\/set measurement range [K]) + 0.1) %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Load impedance (current output):\u003c\/strong\u003e ≤ 600 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Load impedance (voltage output):\u003c\/strong\u003e ≥ 2 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal (current):\u003c\/strong\u003e 0 … 10 mA|2 … 10 mA|0 … 20 mA|4 … 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal (voltage):\u003c\/strong\u003e 0 … 5 V|1 … 5 V|0 … 10 V|2 … 10 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal type:\u003c\/strong\u003e Current|Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Current consumption at nominal supply voltage:\u003c\/strong\u003e ≤ 50 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Nominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Power supply type:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Supply voltage range:\u003c\/strong\u003e ±30 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Step response (typ.):\u003c\/strong\u003e 180 ms (2-wire)|360 ms (3-wire)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695280046217,"sku":"8570801","price":386.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001200000f24000100b6_de_13f30b3f-1752-4191-bd21-acb0e7fc34e3.jpg?v=1786986721","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-857-802","provider":"US Automation Controls","version":"1.0","type":"link"}