Plug-in input solid-state / static relay (SSR) with pre-assembled socket base + yellow LED - 2-wire connection - zero-cross switching - WAGO (857 series) - single-pole / single-phase / 1-pole (1P) - control voltage 100-138Vac (115Vac nom.)/100-138Vdc (115Vdc nom.) - Rated voltage 24Vac-240Vac (230Vac nom.) output - Rated current 2A (continuous) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - IP20 - equivalent to 857717
Specifications
- Primary brand: WAGO
- Functions: Plug-in input solid-state / static relay (SSR)
- Design: pre-assembled socket base|yellow LED|2-wire connection|zero-cross switching
- Poles: single-pole / single-phase / 1-pole (1P)
- Frequency: 50Hz / 60Hz main frequency
- Temperature: Processing temperature -25°C...+50°C
- Rated current: 2A (continuous)
- Rated voltage (AC): 24Vac-240Vac (230Vac nom.) output
- Connection type: Push-in CAGE CLAMP connections
- Control Voltage (AC): 100-138Vac (115Vac nom.)
- Control Voltage (DC): 100-138Vdc (115Vdc nom.)
- Mounting mode: DIN-35 rail
- Response time: (switching ON) 10ms / 0.010s|(switching OFF) 10ms / 0.010s
- Dimensions: H94mm x W6mm x D81mm|6mm width
- Material: Polyamide (PA) 66
- Ambient air temperature for operation: -20°C...+60°C
- Ambient air temperature for storage: -40°C...+70°C
- Humidity: 5-85% relative humidity (RH; non-condensing)
- Customs Tariff Number: 85365005000
- eClass code: 27-26-15-03
- GTIN code: 4045454835538
- ETIM code: EC001504
- Order code / Manufacturer SKU: 857-717
- Manufacturer product status: Commercialized
- Equivalent to: 857717
- EAN code: 4045454835538
- Compliant with standard(s): Safety and protection|- Overvoltage category -- III|EN 61000-6-2|EN 61000-6-3|EN 61010-2-201|EN 61373|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03078|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Approvals for hazardous areas|- ATEX - DEKRA EXAM GmbH - EN 60079-0 - certificate BVS_14_ATEX_E_091_X (II 3G Ex ec nC IIC T4 Gc; II 3G Ex ec IIC T4 Gc)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312304000757 (Ex ec IIC T4 Gc)|- IECEx - DEKRA EXAM GmbH - IEC 60079-0 - certificate IECEX_BVS_14.0079X_Issue_3 (Ex ec nC IIC T4 Gc; Ex ec IIC T4 Gc)|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate WAGO22UKEX002X_ec|RoHS compliant with exemption (7(a) / 7(c)-I)|material group I|V-0 flammability rating
- Location of origin: Germany
- Degree of pollution: 2
- Level 1 category: Automation components
- Level 2 category: Control components
- Level 3 category: Control relays
- Product title: Plug-in input solid-state / static relay (SSR) - WAGO
Basic relay
- WAGO Basic Relay: 857-168
Commercial data
- Country of origin: DE
- Customs tariff number: 85365005000
- ECCN: NO US CLASSIFICATION
- eCl@ss 10.0: 27-26-15-03
- eCl@ss 9.0: 27-26-15-03
- ETIM 8.0: EC001504
- ETIM 9.0: EC001504
- GTIN: 4045454835538
- Packaging type: Box
- Product Group: 6 (INTERFACE ELECTRONIC)
- PU (SPU): 25 (1) pcs
Connection data
- Connection technology: Push-in CAGE CLAMP®
- Fine-stranded conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
- Fine-stranded conductor; with insulated ferrule: 0.34 … 1.5 mm² / 22 … 16 AWG
- Solid conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
- Strip length: 9 … 10 mm / 0.35 … 0.39 inches
Environmental Product Compliance
- CAS-No.: 7439-92-1|79-94-7
- REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Lead
- RoHS Compliance Status: Compliant,With Exemption
- RoHS Exemption: 7(a)|7(c)-I
- SCIP notification number (Bulgaria): c8ea262c-3241-4f07-b5e6-b38625949786
- SCIP notification number (Czech Republic): f8ffaba3-1b6f-44f0-99af-28f3fa7cb967
Environmental requirements
- Ambient temperature (operation at UN): -20 … +60 °C
- Ambient temperature (storage): -40 … +70 °C
- Operating altitude (max.): 2000m
- Processing temperature: -25 … +50 °C
- Relative humidity: 5 … 85 % (no condensation permissible)
- Temperature range of connection cable: ≥ (Tambient + 30 K)
Material data
- Color: gray
- Fire load: 0.544MJ
- Flammability class per UL94: V0
- Insulation material (main housing): Polyamide (PA66)
- Material group: I
-
Note (material data):
Information on material specifications can be found here
- Weight: 28.5g
Mechanical data
- Mounting position: horizontal (standing/lying); vertical
- Mounting type: DIN-35 rail
Physical data
- Depth from upper-edge of DIN-rail: 81 mm / 3.189 inches
- Height: 94 mm / 3.701 inches
- Width: 6 mm / 0.236 inches
Safety and protection
- Dielectric strength (control/load circuit) (AC, 1 min): 3.51 kVrms
- Insulation type (between adjacent devices of the same type): Reinforced insulation (safe isolation)
- Insulation type (control/load circuit): Reinforced insulation (safe isolation)
- Insulation type (to adjacent devices of different types): Basic insulation
- Overvoltage category: III
- Pollution degree: 2
- Protection type: IP20
- Rated voltage: 300V
Standards and specifications
- Standards/specifications: EN 61000-6-2|EN 61000-6-3|EN 61373|EN 61010-2-201|UL 508
Technical data
- Control circuit - Input voltage range (high level): 100 … 138 VAC/DC
- Control circuit - Input voltage range (low level): 0 … 25 VAC/VDC
- Control circuit - Nominal input current at UN: 4 mA
- Control circuit - Nominal input voltage UN: 115 VAC/VDC
- Load circuit - Circuit type: 2-wire connection|Zero-voltage switching
- Load circuit - Leakage current at rated voltage: ≤ 1.5 mA
- Load circuit - Limiting continuous current: 2 A
- Load circuit - Nominal output voltage: 230 VAC
- Load circuit - Output voltage range: 24 … 240 VAC
- Load circuit - Switching current (min.): 22 mA
- Load circuit - Switching frequency: 50 Hz / 60 Hz
- Load circuit - Turn-off time: ≤ 10 ms
- Load circuit - Turn-on time: ≤ 10 ms
- Load circuit - Voltage drop: ≤ 1.6 VAC
- Signaling - Status indicator: Yellow LED