{"product_id":"wago-857-643","title":"Wago - 857-642","description":"\u003cp\u003eFixed-type timing relay module with ON- and OFF-delay switching + 2 x separate adjustable time ranges + yellow LED - for railways applications - WAGO (857 series) - single-pole \/ 1-pole (1P) - control voltage 16.8-31.2Vdc (24Vdc nom.; 0.7...1.3 x Uc; SELV) - 1C\/O \/ SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 6A (continuous) \/ 3A (250Vac; AC-15) \/ 2A (24Vdc; DC-13) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - IP20 - material Silver-Tin (AgSnO) contacts - equivalent to 857642\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Fixed-type timing relay module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e ON- and OFF-delay switching|2 x separate adjustable time ranges|yellow LED|for railways applications|Electromechanical design|10V \/ 10mA \/ 24V \/ 1mA recommended minimum switching load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e single-pole \/ 1-pole (1P)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -25°C...+50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 6A (continuous)|3A (250Vac; AC-15)|2A (24Vdc; DC-13)|20A (20ms) AC inrush maximum current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage (AC):\u003c\/strong\u003e 250Vac max. (switching voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage (Uimp):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage (DC):\u003c\/strong\u003e 16.8-31.2Vdc (24Vdc nom.; 0.7...1.3 x Uc; SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay:\u003c\/strong\u003e adjustable time range 0.01-0.1s \/ 0.1-1s \/ 1-10s \/ 10-100s \/ 1-10min \/ 10-100min \/ 1-10h \/ 10-100h|50ms (reset time)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e (OFF=\u0026gt;ON \/ contacts closing) 15ms \/ 0.015s|(ON=\u0026gt;OFF \/ contacts opening) 25ms \/ 0.025s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContacts type:\u003c\/strong\u003e 1C\/O \/ SPDT (Single Pole Double Throw) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H94mm x W6mm x D97.8mm|6mm width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Silver-Tin (AgSnO) contacts|Polyamide (PA) 66 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -25°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-85% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical durability (with load):\u003c\/strong\u003e 50 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical durability (at no load):\u003c\/strong\u003e 5 000 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001439\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-37-16-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821565710\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 857-642\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 857642\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821565710\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- II|EN 50121-3-2|EN 61010-2-201|EN 61373|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03078|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication type:\u003c\/strong\u003e Railways applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e On- and off-delay|control input - ON-delay and single-shot leading edge - ON-delay and single-shot leading edge|control input - Single-shot leading and trailing edge|control input - Pulse sequence evaluation|control input - Repeat cycle timer|pulse start - Repeat cycle timer|interval start|control input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Control components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Control relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Fixed-type timing relay module - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-37-16-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-37-16-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001439\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001439\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821565710\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e bag\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 3b577f50-a8f7-4931-8018-0273f6744d4b\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 889e1473-2ccc-4f3e-a962-66f08b6b9513\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 35d84d84-84a7-48a5-8e85-d9c076d92980\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 136b2103-8f85-44a8-80b6-7238b933cda1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e dd71aaca-a453-4adc-8364-11c848085ff8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e af04b623-8bd2-47b4-abce-f53cba388b21\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 5c6fb437-6cee-4fad-8189-fa67b2d0d9fd\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 73a17d4f-a9bb-46af-bbc7-f6877f9a6d4f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 522673c1-1804-4e5a-9498-50e0be68fdf0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 5bd150b2-0987-4017-bfb4-1981a4b51fe7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 0b76abbd-17a8-4f64-8a2e-aa807581c02d\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 19f39985-f039-470b-ab2a-201a399fb747\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 5374616e-6c99-43e6-841d-734dff001fba\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e dd5fcbe1-4312-41f3-824d-0cdb44fc18be\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -25 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -25 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 85 % (no condensation permissible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 30 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.013MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 27g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The 6 (GND) and 8 (GND) connections are internally commoned. The current carrying capacity is: 4 A (max.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 97.8 mm \/ 3.85 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 94 mm \/ 3.701 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6 mm \/ 0.236 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (control\/load circuit) (AC, 1 min):\u003c\/strong\u003e 3.51 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (open contact) (AC, 1 min):\u003c\/strong\u003e 1 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse withstand voltage:\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61373|EN 50121-3-2|UL 508|EN 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Functions:\u003c\/strong\u003e On- and off-delay (with control input)|On-delay and single-shot leading edge|On-delay and single-shot leading edge (with control input)|Single-shot leading and trailing edge (with control input)|Pulse sequence evaluation (with control input)|Repeat cycle timer (pulse start)|Repeat cycle timer (interval start), control input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Input voltage range:\u003c\/strong\u003e ±30 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Minimum pulse length (control input):\u003c\/strong\u003e 10ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input current at U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 18 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input voltage U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC (SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Reset time:\u003c\/strong\u003e 50ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Time range:\u003c\/strong\u003e Adjustable: 0.01 … 0.1 s; 0.1 … 1 s; 1 … 10 s; 10 … 100 s; 1 … 10 min; 10 … 100 min; 1 … 10 h; 10 … 100 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Bounce time (typ.):\u003c\/strong\u003e 3.5ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Contact material (relay):\u003c\/strong\u003e AgSnO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Digital output (DO):\u003c\/strong\u003e U\u003csub\u003eN\u003c\/sub\u003e - 1 V ; 100 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Drop-out time (typ.):\u003c\/strong\u003e 25ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Electrical life (NO; resistive load; 23 °C):\u003c\/strong\u003e 50 x 10³ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Inrush current (resistive) max.:\u003c\/strong\u003e (AC) 20 A \/ 0.02 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Limiting continuous current:\u003c\/strong\u003e 6 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Mechanical life:\u003c\/strong\u003e 5 x 10⁶ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Number of changeover\/switchover contacts:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Pull-in time (typ.):\u003c\/strong\u003e 15ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Recommended minimum load:\u003c\/strong\u003e 10 V \/ 10 mA; 24 V \/ 1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Short circuit protection (load circuit):\u003c\/strong\u003e 6.3 A; Slow (T); testing based on EN 61812-1 with a short-circuit current of 100 ADC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching capacity:\u003c\/strong\u003e AC-15: 3 A \/ 250 VAC; DC-13: 2 A \/ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching power (resistive) max.:\u003c\/strong\u003e AC 1500 VA; DC (see load limit curve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching Voltage, Max.:\u003c\/strong\u003e 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling - Status indicator:\u003c\/strong\u003e Yellow LED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695444279433,"sku":"8570642","price":215.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000180003c069000100b6_de_206e9976-0849-4839-b04e-7b1def6b78e5.jpg?v=1786988779","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-857-643","provider":"US Automation Controls","version":"1.0","type":"link"}