{"product_id":"wago-857-532","title":"Wago - 857-531","description":"\u003cp\u003eAnalog threshold value switch with DIP \/ software configuration - WAGO (857 series) - with 1 x analog input (-20...+20mA \/ -10...+10Vdc \/ 0-30Vdc) - supply voltage 16.8-31.2Vdc (24Vdc nom.; SELV) - with Push-in CAGE CLAMP spring connections - DIN-35 rail mounting (6mm width) - IP20 - rated for -25°C...+70°C ambient - equivalent to 857531\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Analog threshold value switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e DIP \/ software configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 16.8-31.2Vdc (24Vdc nom.; SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs:\u003c\/strong\u003e 1 x digital output (SPDT (Single Pole Double Throw) rly. contact type; 250Vac; 6A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 1 x analog input (-20...+20mA \/ -10...+10Vdc \/ 0-30Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e ≤ 0.1% (transmission error)|≤ 0.01%\/K (temperature coefficient)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H94mm x W6mm x D97.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polyamide (PA) 66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -25°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-85% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 25mA (24Vdc; at nominal load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC002653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-21-01-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 90303370000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4066966662375\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 857-531\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 857531\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454885229\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- II|CE|EN 61373|EMC immunity to interference|- EN 61000-6-2|- EN 61131-2|- EN 61326-1|- EN 50121-3-2|EMC emission of interference|- EN 61000-6-4|- EN 61131-2|- EN 61326-1|- EN 50121-3-2|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03078|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 40179_B0|- DNV - DNV Germany GmbH - DNV-CG-0339 \/ Aug.2021 - certificate TAA00001D1|Approvals for hazardous areas|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - ANSI\/ISA 12.12.01 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Analog threshold value switch - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 90303370000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-21-01-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-21-01-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4066966662375\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e bag\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|75980-60-8|79-94-7|80-05-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 70c9867b-9228-49b1-8871-0ff4880135a1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 475d917f-e72d-4462-a17f-b1550a3b1393\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -25 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 85 % (no condensation permissible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 35 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.013MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 38.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cb\u003eUse shielded signal lines!\u003c\/b\u003e\u003cbr\u003eOnly use shielded signal lines for analog input and output signals.\u003cbr\u003eOnly then can you ensure that the accuracy and interference immunity specified for the device can be achieved, even in the presence of interference acting on the signal cable.|Additional setting options via the WAGO Interface Configuration Software|\u003cbr\u003e      \u003cb\u003eUse shielded signal lines!\u003c\/b\u003e\u003cbr\u003e      Only use shielded signal lines for analog input and output signals.\u003cbr\u003e      Only then can you ensure that the accuracy and interference immunity specified for the device can be achieved, even in the presence of interference acting on the signal cable.\u003cbr\u003e\u003cbr\u003e     Additional setting options via WAGO Interface Configuration Software or WAGO Interface Configuration App\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e Input and digital output must be safely isolated from any hazardous live parts!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 97.8 mm \/ 3.85 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 94 mm \/ 3.701 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6 mm \/ 0.236 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Insulation type (adjacent devices):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Insulation type (input\/supply):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Insulation type (relay):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Overvoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Pollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage (input\/relay output\/supply):\u003c\/strong\u003e 3 kVAC; 50 Hz; 1 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e EN 61000-6-4; EN 61131-2; EN 61326-1; EN 50121-3-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e EN 61000-6-2; EN 61131-2; EN 61326-1; EN 50121-3-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61373\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration - Configuration options:\u003c\/strong\u003e Push\/slide switch|DIP switch|WAGO Interface Configuration Software|WAGO Interface Configuration App|Push\/slide switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input current (max.):\u003c\/strong\u003e 22 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input resistance (current input):\u003c\/strong\u003e ≤ 200 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input resistance (voltage input):\u003c\/strong\u003e ≥ 100 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal (current):\u003c\/strong\u003e ±20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal (voltage):\u003c\/strong\u003e ±10 V|0 … 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal type:\u003c\/strong\u003e Voltage|Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input voltage (max.):\u003c\/strong\u003e 31 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Temperature coefficient:\u003c\/strong\u003e ≤ 0.01 %\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (typ.):\u003c\/strong\u003e ≤ 0.1 % of upper-range value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating data - Continuous current (max.):\u003c\/strong\u003e 6 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Continuous current (DO) max.:\u003c\/strong\u003e 100 mA (no internal restriction)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Number of switching thresholds (DO):\u003c\/strong\u003e 2 (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Switching voltage (DO) max.:\u003c\/strong\u003e Supply voltage applied\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Configurable rise\/fall delay time (relay):\u003c\/strong\u003e 0 … 30 s (via software)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Drop-out time (typ.):\u003c\/strong\u003e 4ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Number of changeover\/switchover contacts:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Number of switching thresholds (relay):\u003c\/strong\u003e 1 or 2 (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Switching power (resistive) max.:\u003c\/strong\u003e AC 1500 VA; DC (see load limit curve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Switching Voltage, Max.:\u003c\/strong\u003e 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Current consumption at nominal supply voltage:\u003c\/strong\u003e ≤ 25 mA (+ I\u003csub\u003eDO\u003c\/sub\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Nominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Power supply type:\u003c\/strong\u003e 24 VDC (SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Supply voltage range:\u003c\/strong\u003e ±30 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Hysteresis:\u003c\/strong\u003e Adjustable via DIP switch or software (valid for relay and DO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Step response (typ.):\u003c\/strong\u003e 16 ms\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695578103945,"sku":"8570531","price":327.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/2000-11573140-de_4e58c7ad-4b9e-4fcd-8bb9-1b5b113dfc71.jpg?v=1786990563","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-857-532","provider":"US Automation Controls","version":"1.0","type":"link"}