{"product_id":"wago-857-428","title":"Wago - 857-409","description":"\u003cp\u003eSingle-channel bipolar isolation amplifier with DIP switch - WAGO (857 series) - with 1 x analog input (-10...+10mA \/ -20...+20mA \/ 0-10mA \/ 2-10mA \/ 0-20mA \/ 4-20mA \/ -5...+5Vdc \/ -10...+10Vdc \/ 0-5Vdc \/ 1-5Vdc \/ 0-10Vdc \/ 2-10Vdc) + 1 x analog output (-10...+10mA \/ -20...+20mA \/ 0-20mA \/ 4-20mA \/ -5...+5Vdc \/ -10...+5Vdc \/ 0-5Vdc \/ 1-5Vdc \/ 0-10Vdc \/ 2-10Vdc) - supply voltage 16.8-31.2Vdc (24Vdc nom.) - with Push-in CAGE CLAMP spring connections - DIN-35 rail mounting (6mm width) - IP20 - rated for -25°C...+70°C ambient - equivalent to 857409\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Single-channel bipolar isolation amplifier|Zero \/ span adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e DIP switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 16.8-31.2Vdc (24Vdc nom.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -25°C...+50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 1 x analog input (-10...+10mA \/ -20...+20mA \/ 0-10mA \/ 2-10mA \/ 0-20mA \/ 4-20mA \/ -5...+5Vdc \/ -10...+10Vdc \/ 0-5Vdc \/ 1-5Vdc \/ 0-10Vdc \/ 2-10Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog outputs:\u003c\/strong\u003e 1 x analog output (-10...+10mA \/ -20...+20mA \/ 0-20mA \/ 4-20mA \/ -5...+5Vdc \/ -10...+5Vdc \/ 0-5Vdc \/ 1-5Vdc \/ 0-10Vdc \/ 2-10Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e ≤ 0.1% (transmission error)|≤ 0.01%\/K (temperature coefficient)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H94mm x W6mm x D97.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polyamide (PA) 66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -25°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e ≤ 25mA (default)|40mA max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-21-01-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454828493\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC002653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 857-409\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 857409\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454828493\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- II|CE|DNV|EN 61010-1|EN 61373|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-3|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 40179_B0|- DNV - DNV Germany GmbH - DNV-CG-0339 \/ Aug.2021 - certificate TAA00001D1|- PRS - Polski Rejestr Statkow - certificate TE\/1098\/880590\/23|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX112692X (II 3G Ex ec IIC T4 Gc)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000210 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - certificate IECEX TUN14.0030X|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate WAGO22UKEX004X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - ANSI\/ISA 12.12.01 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Single-channel bipolar isolation amplifier - DIP switch - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-21-01-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-21-01-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454828493\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e bag\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable type:\u003c\/strong\u003e Shielded cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|75980-60-8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 3045ef60-f28a-43e4-9dba-b63435d5553d\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 8f1d744b-8731-4270-a640-73cf63782d7f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 74cd0cd4-d3cc-4fa9-ac76-5a1ca5bb11a1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 0689176b-e48c-48ed-859f-591c9a9bb606\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e ffd652f9-d5f2-45bf-981b-f0fde66c585f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 7c145b78-dbc2-4260-85cc-22a468112985\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 3a00d327-3185-4fcb-a0b8-36a561c46061\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 15951163-bfc4-44d4-b679-9146fa50b484\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 5fd6a05b-6f43-463e-8f9a-4ab07da40dfd\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e ea8b18af-ed6a-4f27-b024-7378eb0f2d3d\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 56e8430c-ad8e-4e3a-b6f2-897614bc0f79\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 62fe04e8-fd16-49c4-be93-f76f40eef9e0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 01c54ad8-3056-427f-8fc0-0b8e8c12d949\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 4527d706-aff0-40c4-95f8-d5d44d48a189\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -25 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -25 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 95 % (no condensation permissible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 10 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.363MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 39.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e      \u003cb\u003eUse shielded signal lines!\u003c\/b\u003e\u003cbr\u003e      Only use shielded signal lines for analog input and output signals.\u003cbr\u003e      Only then can you ensure that the accuracy and interference immunity specified for the device can be achieved, even in the presence of interference acting on the signal cable.\u003cbr\u003e\u003cbr\u003e     Use in the living area is only permitted in conjunction with a power supply that meets the criteria of the living area according to EN 61000-6-3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e Input and output must be safely isolated from any hazardous live parts!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 97.8 mm \/ 3.85 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 94 mm \/ 3.701 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6 mm \/ 0.236 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Insulation type (adjacent devices):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Insulation type (input\/analog output\/supply):\u003c\/strong\u003e Functional insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Overvoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination - Pollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage (input\/output\/supply):\u003c\/strong\u003e 3 kVAC; 50 Hz; 1 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e EN 61000-6-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61010-1|EN 61373|DNV|DNV|EN 61373\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration - Configuration options:\u003c\/strong\u003e DIP switch|Potentiometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input current (max.):\u003c\/strong\u003e 50 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input resistance (current input):\u003c\/strong\u003e ≤ 50 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input resistance (voltage input):\u003c\/strong\u003e 1 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal (current):\u003c\/strong\u003e ±10 mA|0 … 10 mA|2 … 10 mA|±20 mA|0 … 20 mA|4 … 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal (voltage):\u003c\/strong\u003e ±5 V|0 … 5 V|1 … 5 V|±10 V|0 … 10 V|2 … 10 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal type:\u003c\/strong\u003e Voltage|Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input voltage (max.):\u003c\/strong\u003e 32 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Zero\/span adjustment:\u003c\/strong\u003e ±5 % of upper-range value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Temperature coefficient:\u003c\/strong\u003e ≤ 0.01 %\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (max.):\u003c\/strong\u003e ≤ 0.2 % of upper-range value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (typ.):\u003c\/strong\u003e ≤ 0.1 % of upper-range value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (under interference):\u003c\/strong\u003e ≤ 15 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Load impedance (current output):\u003c\/strong\u003e ≤ 600 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Load impedance (voltage output):\u003c\/strong\u003e ≥ 2 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal (current):\u003c\/strong\u003e ±10 mA|0 … 10 mA|2 … 10 mA|±20 mA|0 … 20 mA|4 … 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal (voltage):\u003c\/strong\u003e ±5 V|0 … 5 V|1 … 5 V|±10 V|0 … 10 V|2 … 10 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal type:\u003c\/strong\u003e Current|Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Residual ripple:\u003c\/strong\u003e ≤ 10 mV (rms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Current consumption (default):\u003c\/strong\u003e ≤ 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Current consumption (max.):\u003c\/strong\u003e ≤ 40 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Nominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Power supply type:\u003c\/strong\u003e 24 VDC (SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Supply voltage range:\u003c\/strong\u003e ±30 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Limit frequency:\u003c\/strong\u003e 100 Hz \/ 5 kHz (configurable via DIP switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Step response (typ.):\u003c\/strong\u003e 3.5 ms (100 Hz)|68 µs (5 kHz)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695343419529,"sku":"8570409","price":430.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001200001154000100b6_de_c11c47a5-3ca2-4a45-9386-927f5a7084c7.jpg?v=1786987811","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-857-428","provider":"US Automation Controls","version":"1.0","type":"link"}