Wago - 857-368

$44.45
Sale price  $44.45 Regular price 

Wago - 857-368

$44.45
Sale price  $44.45 Regular price 

Plug-in relay assembly with socket base and ejector + yellow LED - WAGO (857 series) - single-pole / 1-pole (1P) - control voltage 184-253Vac (230Vac nom.; 50/60Hz; 0.8...1.1 x Uc)/184-253Vdc (230Vdc nom.; 0.8...1.1 x Uc) - 1C/O / SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 50mA (30Vdc; DC-13) (max. recommended current to avoid evaporating the Gold flash) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - IP20 - material Hard Gold-plated Silver-Nickel (AgNi + Au) contacts - equivalent to 857368

Specifications

  • Primary brand: WAGO
  • Functions: Plug-in relay assembly
  • Design: socket base and ejector|yellow LED|Electromechanical design|1V / 1mA / 1mW recommended minimum switching load
  • Poles: single-pole / 1-pole (1P)
  • Temperature: Processing temperature -25°C...+50°C
  • Rated current: 50mA (30Vdc; DC-13) (max. recommended current to avoid evaporating the Gold flash)|6A (continuous)|3A (AC-15; 250 Vac)|2A (DC-13; 24Vdc)|20A (20ms) AC inrush maximum current
  • Rated operating voltage (Ue): 300V
  • Rated voltage (AC): 250Vac max. (switching voltage)
  • Rated impulse voltage (Uimp): 4kV
  • Connection type: Push-in CAGE CLAMP connections
  • Control Voltage (AC): 184-253Vac (230Vac nom.; 50/60Hz; 0.8...1.1 x Uc)
  • Control Voltage (DC): 184-253Vdc (230Vdc nom.; 0.8...1.1 x Uc)
  • Mounting mode: DIN-35 rail
  • Response time: (OFF=>ON / contacts closing) 15ms / 0.015s|(ON=>OFF / contacts opening) 25ms / 0.025s
  • Contacts type: 1C/O / SPDT (Single Pole Double Throw) contact
  • Dimensions: H94mm x W6mm x D81mm|6mm width
  • Material: Hard Gold-plated Silver-Nickel (AgNi + Au) contacts|Polyamide (PA) 66 housing
  • Ambient air temperature for operation: -40°C...+60°C
  • Ambient air temperature for storage: -40°C...+70°C
  • Humidity: 5-85% relative humidity (RH; non-condensing)
  • Electrical durability (with load): 50 000operations
  • Mechanical durability (at no load): 5 000 000operations
  • eClass code: 27-37-16-01
  • GTIN code: 4045454673482
  • ETIM code: EC001437
  • Customs Tariff Number: 85364900990
  • Order code / Manufacturer SKU: 857-368
  • Manufacturer product status: Commercialized
  • Equivalent to: 857368
  • EAN code: 4045454673482
  • Compliant with standard(s): Safety and protection|- Overvoltage category -- III|Safety information -- Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation.|An end stop must be fitted to devices of other types for compliance with the reinforced insulation requirements.|ATEX|DNV|EN 61010-2-201|EN 61373|EN 61810-1|IECEx|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03078|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 40179_B0|- DNV - DNV Germany GmbH - DNV-CG-0339 / Aug.2021 - certificate TAA00001D1|- PRS - Polski Rejestr Statkow - certificate TE/1098/880590/23|Approvals for hazardous areas|- ATEX - DEKRA EXAM GmbH - EN 60079-0 - certificate BVS_14_ATEX_E_091_X (II 3G Ex ec nC IIC T4 Gc; II 3G Ex ec IIC T4 Gc)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312304000757 (Ex ec nC IIC T4 Gc)|- IECEx - DEKRA EXAM GmbH - IEC 60079-0 - certificate IECEX_BVS_14.0079X_Issue_3 (Ex ec nC IIC T4 Gc; Ex ec IIC T4 Gc)|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX002X_ec nC|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (7(a) / 7(c)-I)|material group I|V-0 flammability rating
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Control components
  • Level 3 category: Control relays
  • Product title: Plug-in relay assembly - WAGO

Basic relay

  • WAGO Basic Relay: 857-157

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85364900990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-37-16-01
  • eCl@ss 9.0: 27-37-16-01
  • ETIM 8.0: EC001437
  • ETIM 9.0: EC001437
  • GTIN: 4045454673482
  • Packaging type: box
  • Product Group: 6 (INTERFACE ELECTRONIC)
  • PU (SPU): 25 (1) pcs

Connection data

  • Connection technology: Push-in CAGE CLAMP®
  • Fine-stranded conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Fine-stranded conductor; with insulated ferrule: 0.34 … 1.5 mm² / 22 … 16 AWG
  • Solid conductor: 0.34 … 2.5 mm² / 22 … 14 AWG
  • Strip length: 9 … 10 mm / 0.35 … 0.39 inches

Environmental Product Compliance

  • CAS-No.: 7439-92-1|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Lead
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 7(a)|7(c)-I
  • SCIP notification number (Bulgaria): 9d4d1dd9-ae5e-427e-8514-4177ee66f04f
  • SCIP notification number (Czech Republic): 1474dc2a-58de-4f57-8c28-1ffcddcfdbb1

Environmental requirements

  • Ambient temperature (operation at UN): -40 … +60 °C
  • Ambient temperature (storage): -40 … +70 °C
  • Operating altitude (max.): 2000m
  • Processing temperature: -25 … +50 °C
  • Relative humidity: 5 … 85 % (no condensation permissible)
  • Temperature range of connection cable: ≥ (Tambient + 30 K)

Material data

Mechanical data

  • Mounting position: Horizontal (standing/lying); vertical
  • Mounting type: DIN-35 rail

Notes

  • Note: To prevent damaging the gold layer, 30 V switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life.|To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
  • Safety Information: Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.

Physical data

  • Depth from upper-edge of DIN-rail: 81 mm / 3.189 inches
  • Height: 94 mm / 3.701 inches
  • Width: 6 mm / 0.236 inches

Safety and protection

  • Dielectric strength (control/load circuit) (AC, 1 min): 3.51 kVrms
  • Dielectric strength (open contact) (AC, 1 min): 1 kVrms
  • Insulation type (between adjacent devices of the same type): Double insulation (safe isolation)
  • Insulation type (control/load circuit): Reinforced insulation (safe isolation)
  • Insulation type (to adjacent devices of different types): Basic insulation
  • Overvoltage category: III
  • Pollution degree: 2
  • Protection type: IP20
  • Rated impulse withstand voltage: 4kV
  • Rated voltage: 300V
  • Safety Information: Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.
  • Type of circuits: Mains circuits

Standards and specifications

  • Standards/specifications: EN 61010-2-201|EN 61810-1|EN 61373|UL 508|ATEX|IECEx|DNV

Technical data

  • Control circuit - Input voltage range: -20 … +10 %
  • Control circuit - Nominal frequency range (input voltage): 50 … 60 HzAC / 0 HzDC
  • Control circuit - Nominal input current at UN: 4 mA
  • Control circuit - Nominal input voltage UN: 230 VAC/VDC
  • Load circuit - Bounce time (typ.): 3.5ms
  • Load circuit - Contact material (relay): AgNi + Au
  • Load circuit - Drop-out time (typ.): 25ms
  • Load circuit - Electrical life (NO; resistive load; 23 °C): 50 x 10³ switching operations
  • Load circuit - Inrush current (resistive) max.: (AC) 20 A / 0.02 s
  • Load circuit - Limiting continuous current: 6 A
  • Load circuit - Mechanical life: 5 x 10⁶ switching operations
  • Load circuit - Number of changeover/switchover contacts: 1
  • Load circuit - Pull-in time (typ.): 15ms
  • Load circuit - Recommended minimum load: 1 V / 1 mA / 1 mW
  • Load circuit - Switching capacity: AC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC
  • Load circuit - Switching frequency with/without load (max.): 6 min-1 / 180 min-1
  • Load circuit - Switching power (resistive) max.: AC 1500 VA; DC (see load limit curve)
  • Load circuit - Switching Voltage, Max.: 250 VAC
  • Signaling - Status indicator: Yellow LED

You may also like