{"product_id":"wago-857-306","title":"Wago - 857-304","description":"\u003cp\u003ePlug-in relay assembly with socket base and ejector + yellow LED - WAGO (857 series) - single-pole \/ 1-pole (1P) - control voltage 20.4-28.8Vdc (24Vdc nom.; 0.85...1.2 x Uc) - 1C\/O \/ SPDT (Single Pole Double Throw) contact - Electromechanical design - Rated current 6A (continuous) \/ 3A (250Vac; AC-15) \/ 2A (24Vdc; DC-13) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (6mm width) - IP20 - material Silver-Tin (AgSnO) contacts - equivalent to 857304\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Plug-in relay assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e socket base and ejector|yellow LED|Electromechanical design|10V \/ 10mA \/ 24V \/ 1mA recommended minimum switching load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e single-pole \/ 1-pole (1P)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -25°C...+50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 6A (continuous)|3A (250Vac; AC-15)|2A (24Vdc; DC-13)|20A (20ms) AC inrush maximum current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage (AC):\u003c\/strong\u003e 250Vac max. (switching voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage (Uimp):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage (DC):\u003c\/strong\u003e 20.4-28.8Vdc (24Vdc nom.; 0.85...1.2 x Uc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e (OFF=\u0026gt;ON \/ contacts closing) 8ms \/ 0.008s|(ON=\u0026gt;OFF \/ contacts opening) 8ms \/ 0.008s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContacts type:\u003c\/strong\u003e 1C\/O \/ SPDT (Single Pole Double Throw) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H94mm x W6mm x D81mm|6mm width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Silver-Tin (AgSnO) contacts|Polyamide (PA) 66 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -40°C...+60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-85% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical durability (with load):\u003c\/strong\u003e 50 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical durability (at no load):\u003c\/strong\u003e 5 000 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821797807\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 857-304\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 857304\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821797807\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- III|Safety information -- Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation.|An end stop must be fitted to devices of other types for compliance with the reinforced insulation requirements.|ATEX|DNV|EN 61010-2-201|EN 61373|EN 61810-1|GL|IECEx|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03078|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.4|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 40179_B0|- DNV - DNV Germany GmbH - DNV-CG-0339 \/ Aug.2021 - certificate TAA00001D1|- PRS - Polski Rejestr Statkow - certificate TE\/1098\/880590\/23|Approvals for hazardous areas|- ATEX - DEKRA EXAM GmbH - EN 60079-0 - certificate BVS_14_ATEX_E_091_X (II 3G Ex ec nC IIC T4 Gc; II 3G Ex ec IIC T4 Gc)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312304000757 (Ex ec nC IIC T4 Gc)|- IECEx - DEKRA EXAM GmbH - IEC 60079-0 - certificate IECEX_BVS_14.0079X_Issue_3 (Ex ec nC IIC T4 Gc; Ex ec IIC T4 Gc)|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX002X_ec nC|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (7(a))|material group I|V-0 flammability rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Control components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Control relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Plug-in relay assembly - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBasic relay\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWAGO Basic Relay:\u003c\/strong\u003e 857-152\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821797807\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 25 (1) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.34 … 1.5 mm² \/ 22 … 16 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 7439-92-1|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Lead\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 7(a)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 890bbd29-8a39-46b4-aa2b-b445d7383193\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e cd09fda5-b324-4734-995a-ff29c0c9eda6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 04a750e3-84ea-4ba5-9ab2-55266b4db0b2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 6dc67810-1040-4e3a-8eea-02782e900886\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 77efef82-3203-4bde-a1bd-42f7117d1652\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 7c985561-ce96-4278-8f64-22962c26fcea\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 6f74c20f-88ae-49b6-b0b5-f967866300f0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e c16952ac-475c-4c3c-a38b-72d416451f94\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e b36536ad-167a-4b9e-88f3-28cb23c555a6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 9f92e62d-bd04-48c9-8dc1-d98000af3646\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 92b96baf-e008-48e0-b506-aea3cd047c43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e d641b813-4032-4bec-8ce1-00daa7dd4104\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e accd36a7-2fff-41da-bcac-fd6f86b4a8e2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 2a874ee1-c3dd-4c7c-b371-75ad3afd11c6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -40 … +60 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -25 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 85 % (no condensation permissible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 30 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.544MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 31.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal (standing\/lying); vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 81 mm \/ 3.189 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 94 mm \/ 3.701 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 6 mm \/ 0.236 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (control\/load circuit) (AC, 1 min):\u003c\/strong\u003e 3.51 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (open contact) (AC, 1 min):\u003c\/strong\u003e 1 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (between adjacent devices of the same type):\u003c\/strong\u003e Double insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (control\/load circuit):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation type (to adjacent devices of different types):\u003c\/strong\u003e Basic insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse withstand voltage:\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of circuits:\u003c\/strong\u003e Mains circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e ATEX|IECEx|DNV|EN 61010-2-201|EN 61810-1|EN 61373|UL 508|GL|ATEX|IEC Ex\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Input voltage range:\u003c\/strong\u003e -15 … +20 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input current at U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input voltage U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Bounce time (typ.):\u003c\/strong\u003e 3.5ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Contact material (relay):\u003c\/strong\u003e AgSnO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Drop-out time (typ.):\u003c\/strong\u003e 6ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Electrical life (NO; resistive load; 23 °C):\u003c\/strong\u003e 50 x 10³ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Inrush current (resistive) max.:\u003c\/strong\u003e (AC) 20 A \/ 0.02 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Limiting continuous current:\u003c\/strong\u003e 6 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Mechanical life:\u003c\/strong\u003e 5 x 10⁶ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Number of changeover\/switchover contacts:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Pull-in time (typ.):\u003c\/strong\u003e 6ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Recommended minimum load:\u003c\/strong\u003e 10 V \/ 10 mA; 24 V \/ 1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Short circuit protection (load circuit):\u003c\/strong\u003e 4 A; Fast (F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching capacity:\u003c\/strong\u003e AC-15: 3 A \/ 250 VAC; DC-13: 2 A \/ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching frequency with\/without load (max.):\u003c\/strong\u003e 6 min\u003csup\u003e-1\u003c\/sup\u003e \/ 180 min\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching power (resistive) max.:\u003c\/strong\u003e AC 1500 VA; DC (see load limit curve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching Voltage, Max.:\u003c\/strong\u003e 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling - Status indicator:\u003c\/strong\u003e Yellow LED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695227617417,"sku":"51285597","price":22.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001d00011e53000100b6_de_d6176800-47b6-4910-b413-af7475356e65.jpg?v=1786985943","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-857-306","provider":"US Automation Controls","version":"1.0","type":"link"}