{"product_id":"wago-789-666","title":"Wago - 789-665","description":"\u003cp\u003eWAGO component - equivalent to 789665\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4066966120820\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 789-665\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 789665\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4066966120820\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Ground resistance signaling module; Ground fault alarm via digital output; Supply voltage 24Vdc; Module width 18mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Power supply - Nominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e -- 24 VDC (SELV)|Power supply - Supply voltage range (DC) -- 18...31.2 VDC|Power supply - Current consumption at nominal supply voltage -- ≤ 40mA|Power supply - Power loss P\u003csub\u003el\u003c\/sub\u003e -- ≤ 1.7W|Power supply - Current at ground fault (24 VDC) max. -- 56mA|Signaling - Operation status indicator -- 1 x LED \"Status OK\" (green)|Signaling - Signaling -- 1 x LED \"Iso Alarm\" (red) \/ 1 x LED \"Iso Alarm\" 24V - Ground (yellow) \/ 1 x LED \"Iso Alarm\" 0V - Ground (yellow) \/ 1 x Signal output \"Iso OK\"|Iso OK contact - Switching voltage (max.) -- 48 VDC (SELV)|Iso OK contact - Continuous current (max.) -- 500mA (for general use)|Iso OK contact - Number of Iso OK contacts connected in series (max.) -- 25 (Limit value type 1); 32 (Limit value type 2 and 3) (per IEC 61131)|Iso OK contact - Function -- 1 make contact (NO); closed with applied power supply and insulation resistance \u0026gt; limit value|Circuit protection - Backup fusing (required) -- The fuse must be placed in the output circuit of the power supply. The fuse must be adapted to the power supply used and must trip safely in case of a short circuit. The module is designed for use with a 10A (max. ) fuse or with a 10 ADC (max.) circuit breaker (characteristic B or C).|Safety and protection - Pollution degree -- 2|Safety and protection - Overvoltage category -- II|Safety and protection - Protection type -- IP20|Safety and protection - Test voltage (supply\/Iso OK contact) -- 1.5kVAC; 50...60Hz; 1 min|Safety and protection - MTBF -- \u0026gt; 600000 h (per MIL-HDBK-217F2)|Mode Ungrounded circuit - Response value for alarm at nominal voltage -- 4kΩ (at U\u003csub\u003eS \u003c\/sub\u003e= 24 V; for other U\u003csub\u003eS\u003c\/sub\u003e values see diagram for signaling threshold)|Mode Ungrounded circuit - Response time -- 1s|Mode Ungrounded circuit - Hysteresis (typ.) -- 1kΩ|Mode Grounded circuit - Response value for alarm at nominal voltage -- 4kΩ (at U\u003csub\u003eS \u003c\/sub\u003e= 24 V; for other U\u003csub\u003eS\u003c\/sub\u003e values see diagram for signaling threshold)|Mode Grounded circuit - Response time -- 10s|Mode Grounded circuit - Hysteresis (typ.) -- 1kΩ|Connection data - Connection type 1 -- X1.x|Connection data - Connection technology -- Push-in CAGE CLAMP|Connection data - WAGO connector -- picoMAX eCOM|Connection data - Solid conductor -- 0.25...1.5mm2 \/ 24...14 AWG \/ 0.2...2.5mm2 \/ 24...12 AWG|Connection data - Fine-stranded conductor -- 0.25...1.5mm2 \/ 24...14 AWG \/ 0.2...2.5mm2 \/ 24...14 AWG|Connection data - Fine-stranded conductor; with insulated ferrule -- 0.25...0.75mm2 \/ 0.25...1.5mm2|Connection data - Fine-stranded conductor; with uninsulated ferrule -- 0.25...1.5mm2 \/ 0.25...2.5mm2|Connection data - Strip length -- 8...9mm \/ 0.31...0.35\" \/ 9...10mm \/ 0.35...0.39\"|Connection data - Connection type -- X2.x|Connection data - WAGO connector 2 -- picoMAX eCOM|Physical data - Width -- 18mm \/ 0.71\"|Physical data - Height -- 90mm \/ 3.54\"|Physical data - Depth from upper-edge of DIN-rail -- 51mm \/ 2.01\"|Mechanical data - Mounting type -- DIN-35 rail|Material data - Weight -- 47g|Environmental requirements - Ambient temperature (operation) -- -40...+70°C|Environmental requirements - Ambient temperature (storage) -- -40...+85°C|Environmental requirements - Temperature range of connection cable -- ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 10 K)|Environmental requirements - Relative humidity -- 5...95% (non-condensing)|Environmental requirements - Operating altitude (max.) -- 3000m|Standards and specifications - Conformity marking -- CE|Standards and specifications - EMC immunity to interference -- EN 61000-6-2|Standards and specifications - EMC emission of interference -- EN 61000-6-3; EN 61000-6-4|Standards and specifications - Standards\/specifications -- UL 61010-2-201|Commercial data - ETIM 9.0 -- EC003596|Commercial data - ETIM 8.0 -- EC003596|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 1 pcs|Commercial data - Packaging type -- Box|Commercial data - Country of origin -- CN|Commercial data - GTIN -- 4066966120820|Commercial data - Customs tariff number -- 85365005000|Environmental Product Compliance - CAS-No. -- 12060-00-3 \/ 1303-86-2 \/ 1317-36-8 \/ 2451-62-9 \/ 540-97-6 \/ 541-02-6 \/ 556-67-2 \/ 7439-92-1|Environmental Product Compliance - REACH Candidate List Substance -- 1;3;5-Tris(oxiran-2-ylmethyl)-1;3;5-triazinane-2;4;6-trione (TGIC) \/ Decamethylcyclopentasiloxane [D5] \/ Diboron trioxide \/ Dodecamethylcyclohexasiloxane [D6] \/ Lead \/ Lead monoxide \/ Lead Titanium oxide (PbTiO3) \/ Octamethylcyclotetrasiloxane [D4]|Environmental Product Compliance - RoHS Compliance Status -- Compliant;With Exemption|Environmental Product Compliance - RoHS Exemption -- 6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II|Environmental Product Compliance - SCIP notification number (Austria) -- 7e2beec6-e444-4533-91ed-ca9c06e08018|Environmental Product Compliance - SCIP notification number (Belgium) -- 3d57bc60-34df-4908-9ee3-46195d31d01a|Environmental Product Compliance - SCIP notification number (Bulgaria) -- 5e35ef1c-882c-48b4-8b73-1d7ec4268ba3|Environmental Product Compliance - SCIP notification number (Czech Republic) -- b6cda593-ddd9-42ff-b4e7-d8fcd1e40d5c|Environmental Product Compliance - SCIP notification number (Denmark) -- a3c41961-0b22-4291-9060-47097b5f95ce|Environmental Product Compliance - SCIP notification number (Finland) -- 91651202-849e-4dc4-bc7a-b390c932d8de|Environmental Product Compliance - SCIP notification number (France) -- d9de80e6-426d-467f-b505-f4cca3e47f38|Environmental Product Compliance - SCIP notification number (Germany) -- 70fe8401-9bb3-4bf6-9b1e-907872456ab1|Environmental Product Compliance - SCIP notification number (Hungary) -- 8e69327f-46d3-4d3e-937a-cc4734bd95c3|Environmental Product Compliance - SCIP notification number (Italy) -- d4d1cefc-62b0-4092-9838-e72a05cfb2df|Environmental Product Compliance - SCIP notification number (Netherlands) -- 2f63a4bb-7d52-4087-9cdb-85d03b2defa7|Environmental Product Compliance - SCIP notification number (Poland) -- 403f29a9-bab2-4cc7-a1fa-13daa7af1f17|Environmental Product Compliance - SCIP notification number (Romania) -- bdb7e5dd-9b1d-4ca5-b22f-3b058c47d4f7|Environmental Product Compliance - SCIP notification number (Sweden) -- 97170ea2-76b4-4ba8-9f9a-a9e56636c480\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCircuit protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup fusing (required):\u003c\/strong\u003e The fuse must be placed in the output circuit of the power supply. The fuse must be adapted to the power supply used and must trip safely in case of a short circuit. The module is designed for use with a 10 A (max. ) fuse or with a 10 ADC (max.) circuit breaker (characteristic B or C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85365005000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC003596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC003596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4066966120820\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e|Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e X2.x\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e X1.x\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 24 … 14 AWG|0.2 … 2.5 mm² \/ 24 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 0.75 mm²|0.25 … 1.5 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 1.5 mm²|0.25 … 2.5 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.25 … 1.5 mm² \/ 24 … 14 AWG|0.2 … 2.5 mm² \/ 24 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches|9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWAGO connector:\u003c\/strong\u003e \u003ci\u003epicoMAX\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e eCOM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWAGO connector 2:\u003c\/strong\u003e \u003ci\u003epicoMAX\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e eCOM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 12060-00-3|1303-86-2|1317-36-8|2451-62-9|540-97-6|541-02-6|556-67-2|7439-92-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 1,3,5-Tris(oxiran-2-ylmethyl)-1,3,5-triazinane-2,4,6-trione (TGIC)|Decamethylcyclopentasiloxane [D5]|Diboron trioxide|Dodecamethylcyclohexasiloxane [D6]|Lead|Lead monoxide|Lead titanium oxide (PbTiO3)|Octamethylcyclotetrasiloxane [D4]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 7e2beec6-e444-4533-91ed-ca9c06e08018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 3d57bc60-34df-4908-9ee3-46195d31d01a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 5e35ef1c-882c-48b4-8b73-1d7ec4268ba3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e b6cda593-ddd9-42ff-b4e7-d8fcd1e40d5c\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e a3c41961-0b22-4291-9060-47097b5f95ce\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 91651202-849e-4dc4-bc7a-b390c932d8de\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e d9de80e6-426d-467f-b505-f4cca3e47f38\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 70fe8401-9bb3-4bf6-9b1e-907872456ab1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 8e69327f-46d3-4d3e-937a-cc4734bd95c3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e d4d1cefc-62b0-4092-9838-e72a05cfb2df\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 2f63a4bb-7d52-4087-9cdb-85d03b2defa7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 403f29a9-bab2-4cc7-a1fa-13daa7af1f17\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e bdb7e5dd-9b1d-4ca5-b22f-3b058c47d4f7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 97170ea2-76b4-4ba8-9f9a-a9e56636c480\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 3000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 95 % (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 10 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIso OK contact\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous current (max.):\u003c\/strong\u003e 500 mA (for general use)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e 1 make contact (NO); closed with applied power supply and insulation resistance \u0026gt; limit value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Iso OK contacts connected in series (max.):\u003c\/strong\u003e 25 (Limit value type: 1); 32 (Limit value type: 2 and 3) (per IEC 61131)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching voltage (max.):\u003c\/strong\u003e 48 VDC (SELV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 47g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMode: Grounded circuit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis (typ.):\u003c\/strong\u003e 1kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 10s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value for alarm at nominal voltage:\u003c\/strong\u003e 4 kΩ (at U\u003csub\u003eS \u003c\/sub\u003e= 24 V; for other U\u003csub\u003eS\u003c\/sub\u003e values see diagram for signaling threshold)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMode: Ungrounded circuit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis (typ.):\u003c\/strong\u003e 1kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 1s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse value for alarm at nominal voltage:\u003c\/strong\u003e 4 kΩ (at U\u003csub\u003eS \u003c\/sub\u003e= 24 V; for other U\u003csub\u003eS\u003c\/sub\u003e values see diagram for signaling threshold)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 51 mm \/ 2.01 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 90 mm \/ 3.54 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 18 mm \/ 0.71 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent at ground fault (24 VDC) max.:\u003c\/strong\u003e 56mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption at nominal supply voltage:\u003c\/strong\u003e ≤ 40 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC (SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower loss P\u003csub\u003el\u003c\/sub\u003e:\u003c\/strong\u003e ≤ 1.7 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage range (DC):\u003c\/strong\u003e 18 … 31.2 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e \u0026gt; 600,000 h (per MIL-HDBK-217F2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage (supply\/Iso OK contact):\u003c\/strong\u003e 1.5 kVAC; 50 … 60 Hz; 1 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignaling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation status indicator:\u003c\/strong\u003e 1 x LED “Status OK” (green)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling:\u003c\/strong\u003e 1 x LED “Iso Alarm” (red)|1 x LED “Iso Alarm” 24 V − Ground (yellow)|1 x LED “Iso Alarm” 0 V − Ground (yellow)|1 x Signal output “Iso OK”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e EN 61000-6-3; EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e UL 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695091826825,"sku":"60486091","price":89.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/2480588_de_758dc3ff-2458-4b8b-b07a-71cbc4d7b2ed.jpg?v=1786984526","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-789-666","provider":"US Automation Controls","version":"1.0","type":"link"}