{"product_id":"wago-789-623","title":"Wago - 789-622","description":"\u003cp\u003eAC digital current sensing transducer - WAGO (789 series) - with Modbus RTU + RS-485 communication capability - supply voltage 12-34Vdc (24Vdc nom.) - with 2 x RJ45 connectors - DIN-35 rail mounting (35mm width) - IP20 - rated for -20°C...+70°C ambient - equivalent to 789622\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e AC digital current sensing transducer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 12-34Vdc (24Vdc nom.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e 2 x RJ45 connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e 19.2kbit\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 1 x analog input (0-50A; AC; 14-bits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e ≤ 1% (transmission error)|≤ 0.01%\/K (temperature coefficient)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H90mm x W35mm x D55mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 35mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -20°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 8mA (24Vdc; at nominal load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-21-01-23\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC002475\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 789-622\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 789622\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821374138\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|DIN EN 50178|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-4|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Metering devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Measurement sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 4 category:\u003c\/strong\u003e Transducers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e AC digital current sensing transducer - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-21-01-23\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-21-01-23\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002475\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002475\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e RJ-45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeedthrough for measurement conductor:\u003c\/strong\u003e Ø 15 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|693-98-1|7439-92-1|75980-60-8|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|2-methylimidazole|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e bb694884-3b75-466d-b25c-d1508336f8c8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 9608bd87-8285-473d-9ae7-f40452779e22\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e bff72e14-4f7f-464d-aeb1-9ae6795be378\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 2e7080d2-3286-4942-b074-2c2d040cfab3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e a2a89f30-d51c-4f3f-a9cc-67a8c17949c6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e c6281fb7-616a-4a12-8929-e5946ee21b69\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e e227b69f-504c-4880-bed4-bfc29c2e0b53\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e ed27cc37-e5e7-4e8f-886b-da3f5392e4d6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e b7d62313-a72e-467e-9fd4-b28c10aeffbc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 69fd3825-e613-4b1f-9375-abd05d68b9ce\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 4bcea46f-9970-43bc-b839-af586e763f40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e effb8a89-418f-419f-ae7d-852495d291b2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 976b857e-0e78-4294-a00e-1d66170150f9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 02f0ffe5-8218-4b40-a4df-b24cfa363753\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -20 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.283MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 62.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing design:\u003c\/strong\u003e DIN-rail-mount enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail|DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 55 mm \/ 2.165 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 90 mm \/ 3.543 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 35 mm \/ 1.378 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e DIN EN 50178|DIN EN 50178\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Bus length (max.):\u003c\/strong\u003e ≤ 1200 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Communications:\u003c\/strong\u003e Modbus RTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Interface:\u003c\/strong\u003e RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Number of devices (max.):\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Parity:\u003c\/strong\u003e Even\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Terminating resistor:\u003c\/strong\u003e 150 Ω (can be activated via DIP switch 1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Transmission channels:\u003c\/strong\u003e Half duplex; 8-bit data; 1 stop bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication - Transmission rate:\u003c\/strong\u003e 19.2 kBd\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal (current):\u003c\/strong\u003e 0 … 50 AAC|AC 0 … 50 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal type:\u003c\/strong\u003e Current|Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Measured variable:\u003c\/strong\u003e Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Resolution [bit]:\u003c\/strong\u003e 14bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Temperature coefficient:\u003c\/strong\u003e ≤ 0.01 %\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (typ.):\u003c\/strong\u003e 1 % (typ.); 3 % (max.) of upper-range value (at room temperature)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput – MODBUS - Bus length (max.):\u003c\/strong\u003e 1200m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput – MODBUS - Connector:\u003c\/strong\u003e RJ-45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput – MODBUS - Number of devices (max.):\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput – MODBUS - Terminating resistor:\u003c\/strong\u003e 150 Ω (can be activated via DIP switch 1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Current consumption at nominal supply voltage:\u003c\/strong\u003e ≤ 8 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Nominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Supply voltage range:\u003c\/strong\u003e 12 … 34 VDC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695136030857,"sku":"7890622","price":386.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200001d0002a7a4000100b6_de_4ed6c01f-6ea3-4b24-80df-0d7c77ddc017.jpg?v=1786985536","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-789-623","provider":"US Automation Controls","version":"1.0","type":"link"}