{"product_id":"wago-788-348","title":"Wago - 788-346","description":"\u003cp\u003ePlug-in relay assembly with socket base + manual operation + red LED - WAGO (788 series) - 2-poles (2P) - control voltage 21.6-26.4Vdc (24Vdc nom.; 0.9...1.1 x Uc) - 2C\/O \/ DPDT (Double Pole Double Throw) contact - Electromechanical design - Rated current 8A (continuous) \/ 1.5A (240Vac; AC-15) \/ 1A (24Vdc; DC-13) - with Push-in CAGE CLAMP connections - DIN-35 rail mounting (15mm width) - IP20 - material Silver-Nickel (AgNi) contacts - equivalent to 788346\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Plug-in relay assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e socket base|manual operation|red LED|Electromechanical design|12V \/ 10mA recommended minimum switching load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 2-poles (2P)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Processing temperature -25°C...+50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 8A (continuous)|1.5A (240Vac; AC-15)|1A (24Vdc; DC-13)|16A (20ms) \/ 12A (4s) AC inrush maximum current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage (AC):\u003c\/strong\u003e 250Vac max. (switching voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage (Uimp):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage (DC):\u003c\/strong\u003e 21.6-26.4Vdc (24Vdc nom.; 0.9...1.1 x Uc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e (OFF=\u0026gt;ON \/ contacts closing) 15ms \/ 0.015s|(ON=\u0026gt;OFF \/ contacts opening) 8ms \/ 0.008s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContacts type:\u003c\/strong\u003e 2C\/O \/ DPDT (Double Pole Double Throw) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H86mm x W15mm x D73mm|15mm width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Silver-Nickel (AgNi) contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -40°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical durability (with load):\u003c\/strong\u003e 10 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical durability (at no load):\u003c\/strong\u003e 5 000 000operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4050821226864\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 788-346\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 788346\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821226864\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|Safety information -- A separator plate must be used for voltages greater than 250V between adjacent relay modules|and for compliance with the reinforced insulation requirements.|EN 61010-2-201|EN 61373|EN 61810-1|UL 508|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03084|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Vol.1 Sec.6|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Control components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Control relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Plug-in relay assembly - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBasic relay\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWAGO Basic Relay:\u003c\/strong\u003e 788-936\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85364900990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-37-16-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001437\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4050821226864\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 6 (INTERFACE ELECTRONIC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 15 (1) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.34 … 2.5 mm² \/ 22 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature UL (operation at U\u003csub\u003eN\u003c\/sub\u003e):\u003c\/strong\u003e -40 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -25 … +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 20 K)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.689MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 34.6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Reinforced insulation between coil and contacts|To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 73 mm \/ 2.874 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 86 mm \/ 3.386 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 15 mm \/ 0.591 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (control\/load circuit) (AC, 1 min):\u003c\/strong\u003e 5 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (load\/load circuit) (AC, 1 min):\u003c\/strong\u003e 2.5 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength (open contact) (AC, 1 min):\u003c\/strong\u003e 1 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse withstand voltage:\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61010-2-201|EN 61810-1|EN 61373|UL 508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Input voltage range:\u003c\/strong\u003e ±10 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input current at U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 17 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl circuit - Nominal input voltage U\u003csub\u003eN\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Bounce time (typ.):\u003c\/strong\u003e 7ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Contact material (relay):\u003c\/strong\u003e AgNi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Drop-out time (typ.):\u003c\/strong\u003e 8ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Electrical life (NO; resistive load; 23 °C):\u003c\/strong\u003e 10 x 10³ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Inrush current (resistive) max.:\u003c\/strong\u003e (AC) 16 A \/ 0.02 s; (AC) 12 A \/ 4 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Limiting continuous current:\u003c\/strong\u003e 8 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Mechanical life:\u003c\/strong\u003e 5 x 10⁶ switching operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Number of changeover\/switchover contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Pull-in time (typ.):\u003c\/strong\u003e 15ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Recommended minimum load:\u003c\/strong\u003e 12 V \/ 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching capacity:\u003c\/strong\u003e AC-15: 1.5 A \/ 240 VAC; DC-13: 1 A \/ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching frequency with\/without load (max.):\u003c\/strong\u003e 6 min\u003csup\u003e-1\u003c\/sup\u003e \/ 300 min\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching power (resistive) max.:\u003c\/strong\u003e AC 2000 VA; DC (see load limit curve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad circuit - Switching Voltage, Max.:\u003c\/strong\u003e 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling - Status indicator:\u003c\/strong\u003e Red LED|Mechanical\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695063253129,"sku":"7880346","price":31.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000140003153a000100b6_de_d75e3d62-df3e-4364-be89-ec58d799caa5.jpg?v=1786984605","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-788-348","provider":"US Automation Controls","version":"1.0","type":"link"}