{"product_id":"wago-753-498","title":"Wago - 753-467","description":"\u003cp\u003ePluggable analog input slice unit module - WAGO (753 series) - 2AI; 0-10Vdc; SE - 2I\/O [2AI (2 x analog inputs (0-10Vdc; Single-ended; 12-bits \/ 2ms conversion; 2-wire))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 753467\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Pluggable analog input slice unit module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 5Vdc (supplied by system)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (A\/C) green -- Function AI 1 \/ AI 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e spring CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 2 x analog inputs (0-10Vdc; Single-ended; 12-bits \/ 2ms conversion; 2-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e +-0.2% (measuring error)|+-0.01% (temperature error)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W12mm x D69.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 12mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 60mA (5Vdc; system supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454394486\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 753-467\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 753467\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454394486\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-4|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-AIM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST\/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Programmable Logic Controllers \u0026amp; components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e I-O Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Pluggable analog input slice unit module - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454394486\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 15 (I\/O System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: inputs\/outputs:\u003c\/strong\u003e 6 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Inputs\/Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|25550-51-0|7439-92-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 4-Methyl-1,2-cyclohexanedicarboxylic anhydride|Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 7(c)-I|6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 17daabe6-8ae6-4530-b300-d57a9b24de41\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e b3f1c3ad-5eb0-4578-bc0a-2f9bcef302d9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e fca1075c-04c4-4bf1-a1d4-474daeb3a023\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e e2e54317-76f8-4363-8c6c-03d65966f216\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 2ea724bb-8a2b-4412-8677-dba87838dfe0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e b29ded38-abed-431c-923a-2f37649a1bcd\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 073a340c-d083-4b17-8f46-17425d5e36f0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e fc29d354-7458-4a1a-9a1a-4a5f56d4209a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 03f500ee-b556-4001-87d4-3defa3b8b88a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 03f9e91b-277c-4b7e-8512-aef1c4087032\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 1e387295-0273-4e4d-8a62-4abd51925f18\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 4c8b541a-aef1-4f18-9444-7ae27d3fdaa5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 8bb4f35c-7280-47f5-9ac8-96a261f144e4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 22695d31-16d7-4fa5-9e0f-409ef56e66e5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e Per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 … 2000 m \/ 0 … 6562 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.882MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 40g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePluggable connector:\u003c\/strong\u003e Pluggable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cp\u003ePluggable connectors and coding fingers (753 Series) are not included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 69.8 mm \/ 2.748 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 62.6 mm \/ 2.465 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 12 mm \/ 0.472 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion time (typ.):\u003c\/strong\u003e 2ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption (5 V system supply):\u003c\/strong\u003e 60mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData width:\u003c\/strong\u003e 2 x 16-bit data; 2 x 8-bit control\/status (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (A, C) green: Function AI 1, AI 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage (max.):\u003c\/strong\u003e 35 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal resistance:\u003c\/strong\u003e 130kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500 V system\/field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error (reference temperature):\u003c\/strong\u003e 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error, deviation (max.) from the upper-range value:\u003c\/strong\u003e 0.2%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of analog inputs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution [bit]:\u003c\/strong\u003e 12bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor connection:\u003c\/strong\u003e 2 x (2-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal characteristics:\u003c\/strong\u003e Single-ended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (voltage):\u003c\/strong\u003e 0 … 10 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 5 VDC; via data contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature error (max.) of the upper-range value:\u003c\/strong\u003e 0.01%\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of channels (module):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695416983689,"sku":"51180954","price":451.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/02000028000056a9000100b6_de_7e27e07b-0039-475b-8846-8616ee8aab3b.jpg?v=1786988293","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-753-498","provider":"US Automation Controls","version":"1.0","type":"link"}