{"product_id":"wago-750-8221","title":"Wago - 750-8216","description":"\u003cp\u003eProgrammable Logic Controller (PLC) CPU unit - WAGO (PFC200 series) - PFC200; G2; 2ETH RS CAN DPS - ARM Cortex-A8 1GHz - with 512MB memory (RAM) + 4GB internal memory (flash) - 250 x connections per node + 64 x field devices connection capability - with Modbus RTU + Modbus TCP + Ethernet\/IP + EtherCAT + CANopen + PROFIBUS + RS-232 + RS-485 communication capability - supply voltage 18-31.2Vdc via wiring (24Vdc nom.) - with 2 x RJ45 connectors (fieldbus) + 3 x 9-pin D-sub connectors - DIN-35 rail mounting (112mm width) - with SD and SDHC card slot (up to 32GB) - IP20 - rated for 0°C...+55°C ambient - replaces obsolete component(s) 750-8206 - equivalent to 7508216\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Programmable Logic Controller (PLC) CPU unit|MQTT|DHCP|DNS|NTP|FTP|FTPS|SNMP|HTTP|HTTPS|SSH|Configuration options|- CODESYS V3|- CODESYS Library|- e!COCKPIT|- e!RUNTIME library|- WAGO-I\/O-CHECK|- Web-Based Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 18-31.2Vdc via wiring (24Vdc nom.)|18-31.2Vdc adjustable suppl. to field sensing devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (SYS; RUN; I\/O; CAN; BF; DIA; U1...U4) red\/green\/orange -- Status of system \/ program \/ internal data bus \/ CANopen \/ PROFIBUS \/ PROFIBUS diagnostics \/ status programmable by user (can be used via CODESYS library)|LED (A; B) green -- Status of system power supply \/ field supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor type:\u003c\/strong\u003e ARM Cortex-A8 1GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming languages:\u003c\/strong\u003e Instruction List (IL)|Ladder Diagram (LD)|Function Block Diagram (FBD)|Continuous Function Chart (CFC)|Structured Text (ST)|Sequential Function Chart (SFC)|Programming environment|- CODESYS V3.5 Firmware Release 23 or higher|- e!COCKPIT (based on CODESYS V3) up to Firmware Release 22|- WAGO-I\/O-PRO V2.3 (based on CODESYS V2.3) up to Firmware Release 22\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory capacity:\u003c\/strong\u003e 512MB memory (RAM)|4GB internal memory (flash)|128kB non-volatile memory (hardware)|128kB non-volatile memory (software)|16MB (program memory; CODESYS V2)|32MB (program memory; CODESYS V3)|64MB (data memory; CODESYS V2)|128MB (data memory; CODESYS V3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection capacity:\u003c\/strong\u003e 250 x connections per node|64 x field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e 2 x RJ45 connectors (fieldbus)|3 x 9-pin D-sub connectors|CAGE CLAMP 2-pin (system supply)|CAGE CLAMP 6-pin (field supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e 10Mbit\/s|100Mbit\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W112mm x D71.9mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 112mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -25°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 550mA (24Vdc; at nominal load)|1700mA (system supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-07\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85371091990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC000236\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143759809\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 750-8216\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e 750-8206\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 7508216\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143759809\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Telecontrol protocols|- IEC 60870 (additional license)|- IEC 61850 (additional license as Client or Server)|- DNP3 (additional license)|CE|EMC immunity to interference|- EN 61000-6-2|- marine applications|EMC emission of interference|- EN 61000-6-3|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-PFC750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 22-2219060|- BSH - Bundesamt fuer Seeschifffahrt und Hydrographie - certificate 1104|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 66711\/A0|- DNV - DNV GL SE - DNV-CG-0339 \/ Aug.2021 - certificate TAA0000194|- KR - Korean Register of Shipping - certificate KR HMB05880-AC001|- LR - Lloyds Register EMEA - certificate LR22180952TA|- PRS - Polski Rejestr Statkow - certificate TE\/1101\/880590\/23|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST\/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage type:\u003c\/strong\u003e SD and SDHC card slot (up to 32GB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating System (OS):\u003c\/strong\u003e Real-time Linux (with PREEMPT_RT patch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Programmable Logic Controllers \u0026amp; components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e CPU Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Programmable Logic Controller (PLC) CPU unit - WAGO (PFC200 series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85371091990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-07\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-07\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC000236\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC000236\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143759809\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: communication\/fieldbus:\u003c\/strong\u003e PROFIBUS: 1 x D-sub 9 socket; CANopen: 1 x D-sub 9 plug; Modbus (TCP, UDP): 2 x RJ-45; Modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-485 interface: 1 x D-sub 9 socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: device configuration:\u003c\/strong\u003e 1 x Male connector; 4-pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: field supply:\u003c\/strong\u003e 6 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: system supply:\u003c\/strong\u003e 2 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e System\/field supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|693-98-1|7439-92-1|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|2-methylimidazole|Diboron trioxide|Lead|Lead monoxide|Perfluorobutane sulfonic acid (PFBS) and its salts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e b9fd5afa-0337-4021-8eca-e378fe47c970\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 2435620a-a05f-4cb8-ae93-324c3122fc51\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e d83ad98d-22ad-40fe-b550-71778e46eb23\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e cffe418e-2e41-436f-80a1-73ddc85fc981\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e cbd8f492-fdb2-43a9-ac34-10ffd93b9a2e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 0844fb3c-422c-401b-bf0a-d0436d8fe674\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 7d18f8be-67fb-4ed0-b2a8-3275d95ad5ed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 1b0e5cda-b6c2-412b-bf8b-3622deefbcf2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e df082563-983b-46d4-be43-fb5a224b3be8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e dbf0ec57-3037-41f7-9f30-931b065c9635\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 84b1c473-df7f-4830-a056-d4f123ba8175\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e a3c3560c-ad82-401a-b6cc-ebb7c853989e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 5b20b554-a0b6-441d-8c14-f084d53e9f8d\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e f7d11444-434f-4f38-86f1-7994bdaa17bc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -25 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61000-6-3, marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61000-6-2, marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e Per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 2.883MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K\/100 m); 5000 m (max.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 4g per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 260.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 71.9 mm \/ 2.831 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 64.7 mm \/ 2.547 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 112 mm \/ 4.409 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunications:\u003c\/strong\u003e PROFIBUS|CANopen|Modbus TCP master\/slave|Modbus (UDP), WagoAppPlcModbus Library|Modbus (RTU), WagoAppPlcModbus Library|ETHERNET|EtherNet\/IP\u003csup\u003eTM\u003c\/sup\u003e Adapter (slave)|EtherNet\/IP\u003csup\u003eTM\u003c\/sup\u003e Scanner|EtherCAT® Master|OPC UA Server\/Client|OPC UA Pub\/Sub (can be installed later)|MQTT|RS-232 serial interface|RS-485 interface|BACnet\/IP, \u003cb\u003erequires an additional license\u003c\/b\u003e|Telecontrol protocols, \u003cb\u003erequires an additional license\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration options:\u003c\/strong\u003e CODESYS V3|\u003cb\u003e\u003ci\u003ee!\u003c\/i\u003e\u003c\/b\u003e\u003ci\u003eCOCKPIT\u003c\/i\u003e|WAGO-I\/O-\u003ci\u003eCHECK\u003c\/i\u003e|Web-Based Management|\u003cb\u003e\u003ci\u003ee!\u003c\/i\u003e\u003c\/b\u003e\u003ci\u003eRUNTIME\u003c\/i\u003e library|CODESYS Library\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e Cortex A8; 1 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent carrying capacity (power jumper contacts):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData memory:\u003c\/strong\u003e CODESYS V2: 64 MB; CODESYS V3: 128 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETHERNET protocols:\u003c\/strong\u003e DHCP|DNS|NTP|FTP|FTPS|SNMP|HTTP|HTTPS|SSH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (SYS, RUN, I\/O, CAN, BF, DIA, U1 … U4) red\/green\/orange: Status system, program, internal data bus, CANopen, PROFIBUS, PROFIBUS diagnostics, status programmable by user (can be used via CODESYS library); LED (A, B) green: System power supply status, field supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput and output process image (CAN) max.:\u003c\/strong\u003e 2000 words\/2000 words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput and output process image (internal) max.:\u003c\/strong\u003e 1000 words\/1000 words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput and output process image (Modbus®) max.:\u003c\/strong\u003e CODESYS V2: 1000 words\/1000 words; CODESYS V3: 32000 words\/32000 words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput and output process image (PROFIBUS) max.:\u003c\/strong\u003e 244 bytes\/244 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput current (typ.) at nominal load (24 V):\u003c\/strong\u003e 550mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal memory (flash):\u003c\/strong\u003e 4096MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500 V system\/field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain memory (RAM):\u003c\/strong\u003e 512MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory card slot:\u003c\/strong\u003e Push-push mechanism; Cover lid (sealable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-volatile hardware memory:\u003c\/strong\u003e 128Kbytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-volatile software memory:\u003c\/strong\u003e 128Kbytes|128.Kbytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of modules per node (max.):\u003c\/strong\u003e 250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of modules without a bus extension (max.):\u003c\/strong\u003e 64\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of outgoing power jumper contacts:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating system:\u003c\/strong\u003e Real-time Linux (with PREEMPT_RT patch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram memory:\u003c\/strong\u003e CODESYS V2: 16 MB; CODESYS V3: 32 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming environment:\u003c\/strong\u003e CODESYS V3.5, Firmware Release 23 or higher|\u003cb\u003e\u003ci\u003ee!\u003c\/i\u003e\u003c\/b\u003e\u003ci\u003eCOCKPIT\u003c\/i\u003e (based on CODESYS V3) up to Firmware Release 22|WAGO-I\/O-\u003ci\u003ePRO\u003c\/i\u003e V2.3 (based on CODESYS V2.3), up to Firmware Release 22\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming languages per IEC 61131-3:\u003c\/strong\u003e Instruction List (IL)|Ladder Diagram (LD)|Function Block Diagram (FBD)|Continuous Function Chart (CFC)|Structured Text (ST)|Sequential Function Chart (SFC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (field):\u003c\/strong\u003e 24 VDC (-25 … +30 %); via power jumper contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e connection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecontrol protocols:\u003c\/strong\u003e IEC 60870 (additional license as slave or master)|IEC 61850 (additional license as Client or Server)|DNP3 (additional license as Slave or Master)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal current (system supply):\u003c\/strong\u003e 1,700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission medium (communication\/fieldbus):\u003c\/strong\u003e ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission rate:\u003c\/strong\u003e ETHERNET: 10\/100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of memory card:\u003c\/strong\u003e SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO's memory card)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisualization:\u003c\/strong\u003e Web-Visu\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47696221143177,"sku":"60372882","price":2251.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/020000250003cf80000400b6_de_2000-020000320002033f000100b6-en_2f8afc34-e372-48a1-a558-beff96f3e1a2.jpg?v=1786992399","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-750-8221","provider":"US Automation Controls","version":"1.0","type":"link"}