Wago - 750-669/000-003

$1,276.00
Sale price  $1,276.00 Regular price 

Wago - 750-669/000-003

$1,276.00
Sale price  $1,276.00 Regular price 

Fail-safe / safety DC digital input/rly. output slice unit module - Safety SIL3/Cat4/PLe - WAGO (750 series) - 4FDI/4FRO; 48Vac/ 60Vdc; 6A; PROFIsafe V2 iPar - 8I/O [4DI (4 x digital inputs (fail-safe inputs with test pulse; type-1; clock sensitive; 48Vac)) + 4DO (4 x digital outputs (fail-safe outputs with test pulse / 5-60Vdc / 5-48Vac / 6A per channel))] - with PROFIsafe communication capability - supply voltage 5Vdc (supplied by system) - with Push-in spring CAGE CLAMP connections - DIN-35 rail mounting (48mm width) - IP20 - rated for 0°C...+55°C ambient - compliant with IEC61508-1; IEC61508-2; IEC61508-3; IEC61508-4; IEC61508-5; IEC61508-6; IEC61508-7; EN ISO13849-1; EN 62061 - equivalent to 750669000003

Specifications

  • Primary brand: WAGO
  • Functions: Fail-safe / safety DC digital input/rly. output slice unit module|Configuration options|- PROFIsafe address adjustable via DIP switch or engineering software
  • Supply voltage (DC): 5Vdc (supplied by system)|24Vdc fixed suppl. to field sensing devices
  • Display: LED green/red -- Status/Error I1...I4 / RO1...RO4|LED red (Err) -- Group error|LED green/red (K; PS) -- Diagnostics|LED red (iPar) -- Parameterization
  • Connection type: Push-in spring CAGE CLAMP connections|Push-in spring CAGE CLAMP connections (field suppl.)
  • Mounting mode: DIN-35 rail
  • Digital inputs: 4 x digital inputs (fail-safe inputs with test pulse; type-1; clock sensitive; 48Vac)
  • Digital outputs: 4 x digital outputs (fail-safe outputs with test pulse / 5-60Vdc / 5-48Vac / 6A per channel)
  • Dimensions: H100mm x W48mm x D69.8mm
  • Net Width (mm): 48mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Ambient air temperature for storage: -25°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Shock resistance according to EN 60068-2-27 --15g
  • Current consumption: 145mA (5Vdc; system supply)|50mA (field supply; no external load)
  • ETIM code: EC001599
  • GTIN code: 4055143535588
  • Customs Tariff Number: 85389099990
  • eClass code: 27-24-26-04
  • Order code / Manufacturer SKU: 750-669/000-003
  • Manufacturer product status: Commercialized
  • Equivalent to: 750669000003
  • EAN code: 4055143535588
  • Compliant with standard(s): IEC61508-1|IEC61508-2|IEC61508-3|IEC61508-4|IEC61508-5|IEC61508-6|IEC61508-7|EN ISO13849-1|EN 62061|EMC immunity to interference|- EN 61000-6-2|- EN 61131-2|- EN 61326-3-1|- EN 61000-6-7|EMC emission of interference|- EN 61000-6-4|- EN 61131-2|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DI0750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|Approvals for functional safety|- Prod. Safety Funct. Safety - TUV Rheinland Industrie Service GmbH - certificate No. 968_FSP 2387_00_22|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Class: Safety SIL3/Cat4/PLe
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Safety components
  • Level 2 category: Safety I-O Units
  • Product title: Fail-safe / safety DC digital input/rly. output slice unit module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85389099990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-24-26-04
  • eCl@ss 9.0: 27-24-26-04
  • ETIM 8.0: EC001599
  • ETIM 9.0: EC001599
  • GTIN: 4055143535588
  • Packaging type: Box
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: field supply: 2 x Push-in CAGE CLAMP®
  • Connection technology: inputs/outputs: 18 x Push-in CAGE CLAMP®
  • Connection type: Field supply
  • Connection type 1: Inputs/outputs
  • Fine-stranded conductor: 0.5 … 1.5 mm² / 20 … 14 AWG
  • Solid conductor: 0.5 … 1.5 mm² / 20 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Digitale Ausgänge

  • Actuator connection: 4 x (fail-safe output with test pulse)
  • Number of digital outputs: 4
  • Output circuit design: Relay outputs
  • Output current (module): 24A
  • Signal type: Digital
  • Signal type (voltage): 48 VAC; 60 VDC
  • Switching current (note): Switching current range compatible with the WAGO 75x-66x/000-003 PROFIsafe I/O Module
  • Switching delay: 50ms
  • Switching voltage range: 5 … 60 VDC (SELV/PELV); 5 … 48 VAC

Digitale Eingänge

  • Input characteristic: clock sensitive|Type 1
  • Input current per channel for signal (1) typ.: 2.2mA
  • Number of digital inputs: 4
  • Sensor connection: 4 x (Fail-safe input with test pulse)
  • Signal frequency (max.): 50Hz
  • Signal type: Digital
  • Signal type (voltage): 48 VAC; 60 VDC

Digitale Taktausgänge

  • Output current per channel: 6A
  • Signal type: Digital
  • Signal type (voltage): 48 VAC; 60 VDC

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1|75980-60-8|79-94-7|80-05-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): 72e2b3c2-e12c-46c0-ae48-ce34bd1fa99c
  • SCIP notification number (Belgium): ae9362ac-c439-4425-a3ff-b3eeaa1d05ef
  • SCIP notification number (Bulgaria): 69b42b83-1f2e-4bad-bbee-199b956fcab9
  • SCIP notification number (Czech Republic): c585bd6f-85d0-493e-9d98-dd1f09757ce9
  • SCIP notification number (Denmark): 21dfd6fb-a34c-4d97-a4c7-1db8a2ec5e04
  • SCIP notification number (Finland): dfa7c6f7-c341-4e3c-9c84-770e70458aeb
  • SCIP notification number (France): dec5c374-c58d-4333-93e7-da27a7c0a6a8
  • SCIP notification number (Germany): 06e5b542-025e-4bf6-a8c7-8db11c7f84c5
  • SCIP notification number (Hungary): 56158475-1c7a-4b08-8e00-c58914045bfa
  • SCIP notification number (Italy): c8239abb-4933-4038-9ce6-eb34c108c32a
  • SCIP notification number (Netherlands): 9710cf4a-f775-412e-8944-376eaf7119ab
  • SCIP notification number (Poland): 4da1c540-79f4-403c-afa2-e679af18e674
  • SCIP notification number (Romania): 38554419-3deb-4439-8be3-995805b934e7
  • SCIP notification number (Sweden): 1aaecde0-083e-491f-a44c-5b753a932557

Environmental requirements

  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -25 … +85 °C
  • EMC emission of interference: per EN 61000-6-4, EN 61131-2
  • EMC immunity to interference: per EN 61000-6-2; EN 61131-2; EN 61326-3-1; EN 61000-6-7
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal right, horizontal top, vertical top and vertical bottom
  • Operating altitude: 0 … 2000 m / 0 … 6562 ft
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (without condensation): 95%
  • Shock resistance: 15g per IEC 60068-2-27
  • Vibration resistance: per IEC 60068-2-6

Functional Safety

  • Achievable safety classes: SIL 3; Category 4, PL e
  • Safety standards: IEC 61508-1 … -7; EN ISO 13849-1; EN 62061

General technical data

  • Configuration options: PROFIsafe address adjustable via DIP switch or engineering software
  • Indicators: LED green/red: Status/Error I1 … I4, RO1 … RO4; LED red (Err): Group error; LED green/red (K, PS): Diagnostics; LED red (iPar): Parameterization
  • Isolation voltage: Relay outputs: 48 VAC, 60 VDC
  • Protocols: PROFIsafe V2
  • Total number of channels (module): 8

Material data

  • Fire load: 2.37MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 220.3g

Mechanical data

  • Mounting type: DIN-35 rail

Physical data

  • Depth: 69.8 mm / 2.748 inches
  • Depth from upper-edge of DIN-rail: 62.6 mm / 2.465 inches
  • Height: 100 mm / 3.937 inches
  • Width: 48 mm / 1.89 inches

Technical data

  • Current consumption (5 V system supply): 145mA
  • Current consumption, field supply (module with no external load): 50mA
  • Isolation: 500 V system/field
  • Supply voltage (field): 24 VDC; via pluggable connector (Push-in CAGE CLAMP®connection)
  • Supply voltage (system and sensor): 24 VDC(-25 … +30 %)
  • Supply voltage (system): 5 VDC; via data contacts

You may also like