{"product_id":"wago-750-665-000-1","title":"Wago - 750-665\/000-001","description":"\u003cp\u003eFail-safe \/ safety DC digital input\/output slice unit module - Safety Cat2\/SIL2 or Cat4\/SIL3 - WAGO (750 series) - 4FDI\/4FDO; 24Vdc; 0.5A; PROFIsafe - 8I\/O [4DI (4 x digital inputs (fail-safe inputs with test pulse; clock sensitive; 24Vdc)) + 4DO (4 x digital outputs (fail-safe outputs with test pulse \/ 24Vdc per channel))] - with PROFIsafe communication capability - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (24mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750665000001\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Fail-safe \/ safety DC digital input\/output slice unit module|Configuration options|- PROFIsafe address adjustable via DIP switch or engineering software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 5Vdc (supplied by system)|20.4-28.8Vdc adjustable suppl. to field sensing devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 5Hz switching frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (A-H) green -- Status I1...I8|LED (I-K) red -- internal\/external error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e spring CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital inputs:\u003c\/strong\u003e 4 x digital inputs (fail-safe inputs with test pulse; clock sensitive; 24Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs:\u003c\/strong\u003e 4 x digital outputs (fail-safe outputs with test pulse \/ 24Vdc per channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W24mm x D67.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 24mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -25°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 55mA (5Vdc; system supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454767952\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001599\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85371098990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 750-665\/000-001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 750665000001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454767952\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-4|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-DI0750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST\/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e Safety Cat2\/SIL2 or Cat4\/SIL3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Safety components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Safety I-O Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Fail-safe \/ safety DC digital input\/output slice unit module - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85371098990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001599\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001599\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454767952\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 15 (I\/O System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: inputs\/outputs:\u003c\/strong\u003e 16 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Inputs\/outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDigitale Ausgänge\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator connection:\u003c\/strong\u003e 4 x (fail-safe output with test pulse)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of digital outputs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput circuit design:\u003c\/strong\u003e Power outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse times (max.) (outputs):\u003c\/strong\u003e t\u003csub\u003eon\u003c\/sub\u003e (L-\u0026gt;H) = 13 ms; t\u003csub\u003eoff\u003c\/sub\u003e (H-\u0026gt;L) = 13 ms;  plus 2 x local bus runtime; plus 2 x fieldbus runtime; plus PLC runtime\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (voltage):\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency (max.):\u003c\/strong\u003e 5 Hz; Resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency (max.) (2):\u003c\/strong\u003e 0.1 Hz; Inductive load per IEC 947-5-1, DC 13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency (max.) (3):\u003c\/strong\u003e 5 Hz; Inductive load per IEC 947-5-1, DC 13; with recovery diodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDigitale Eingänge\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput characteristic:\u003c\/strong\u003e clock sensitive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput current per channel for signal (1) typ.:\u003c\/strong\u003e 2.2mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of digital inputs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse times (min. … max.) (inputs):\u003c\/strong\u003e t\u003csub\u003eon\u003c\/sub\u003e (L-\u0026gt;H) = 13 ms … 71 ms; t\u003csub\u003eoff\u003c\/sub\u003e (H-\u0026gt;L) = 13 ms … 26 ms; plus 2 x local bus runtime; plus 2 x fieldbus runtime; plus PLC runtime\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor connection:\u003c\/strong\u003e 4 x (Fail-safe input with test pulse)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (voltage):\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDigitale Taktausgänge\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (voltage):\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 12060-00-3|1303-86-2|1317-36-8|7439-92-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e Diboron trioxide|Lead|Lead monoxide|Lead titanium oxide (PbTiO3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e a7910311-1bf3-4f71-a861-c41c61c1d680\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e d6e2d4d1-38e2-4067-bcb8-52d96ea4a33d\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -25 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal right, horizontal top, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 … 2000 m \/ 0 … 6562 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAchievable safety classes:\u003c\/strong\u003e 4 x Cat. 2\/SIL 2 or 2 x Cat. 4\/SIL 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad reactances (max.):\u003c\/strong\u003e Capacitive 2 nF; inductive corresponding to DC 13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProof test interval:\u003c\/strong\u003e 10years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral technical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration options:\u003c\/strong\u003e PROFIsafe address adjustable via DIP switch or engineering software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (A-H) green: Status I1 … I8; LED (I-K) red: internal, external error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e PROFIsafe V1.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of channels (module):\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e yellow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 2.955MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 101.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 67.8 mm \/ 2.669 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 60.6 mm \/ 2.386 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24 mm \/ 0.945 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent carrying capacity (power jumper contacts):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption (5 V system supply):\u003c\/strong\u003e 55mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500 V system\/field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of incoming power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of outgoing power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (field):\u003c\/strong\u003e 24 VDC (-15 … +20 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 5 VDC; via data contacts\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695309734025,"sku":"51205800","price":896.4,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-750-665-000-1","provider":"US Automation Controls","version":"1.0","type":"link"}