Intrinsically-safe DC digital input slice unit module - Safety SIL3/Cat4/PLe - WAGO (750 series) - 4F-Ex i DI; 24Vdc; PROFIsafe V2 iPar - 4I/O [4DI (4 x digital inputs (fail-safe inputs with test pulse; type-1; clock sensitive; 24Vdc / T1-T2 / adjustable 0-200ms input filter))] - with PROFIsafe communication capability - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (24mm width) - IP20 - rated for 0°C...+55°C ambient - compliant with IEC61508; IEC62061; EN ISO13849; EN 61511 - equivalent to 750663000003

Specifications

  • Primary brand: WAGO
  • Functions: Intrinsically-safe DC digital input slice unit module|Configuration options|- PROFIsafe address adjustable via DIP switch or engineering software
  • Supply voltage (DC): 5Vdc (supplied by system)|24Vdc fixed suppl. to field sensing devices
  • Display: LED (A-D) green/red -- Status/Error I1...I4|LED (E) red -- Group error|LED (F-H) green/red -- Diagnostics
  • Connection type: spring CAGE CLAMP connections
  • Mounting mode: DIN-35 rail
  • Digital inputs: 4 x digital inputs (fail-safe inputs with test pulse; type-1; clock sensitive; 24Vdc / T1-T2 / adjustable 0-200ms input filter)
  • Dimensions: H100mm x W24mm x D67.8mm
  • Net Width (mm): 24mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Ambient air temperature for storage: -25°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g
  • Current consumption: 145mA (5Vdc; system supply)|20mA (field supply; no external load)
  • Power consumption: 3W
  • eClass code: 27-24-26-04
  • Customs Tariff Number: 85389099990
  • ETIM code: EC001599
  • Power dissipation/losses: 1.27W
  • Order code / Manufacturer SKU: 750-663/000-003
  • Manufacturer product status: Commercialized
  • Equivalent to: 750663000003
  • EAN code: 4050821531432
  • Compliant with standard(s): IEC61508|IEC62061|EN ISO13849|EN 61511|CE|EMC immunity to interference|- EN 61000-6-2|- marine applications|EMC emission of interference|- EN 61000-6-3|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DIM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 22-2219060|- DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194|- LR - Lloyds Register EMEA - certificate LR22180952TA|- PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- AEx - UL International Germany GmbH - UL 60079 - certificate E480271|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV12ATEX106032X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000211 (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)|- IECEx - TUV Nord Cert GmbH - IEC 60079 - certificate IECEx TUN12.0039X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)|- INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV_14.1911_X|- UKEx - Element Materials Technology UK - certificate EMA21UKEX0069X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|Approvals for functional safety|- Prod. Safety Funct. Safety - TUV Rheinland Industrie Service GmbH - certificate No. 968_FSP 2387_00_22|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Class: Safety SIL3/Cat4/PLe
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Safety components
  • Level 2 category: Safety I-O Units
  • Product title: Intrinsically-safe DC digital input slice unit module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85389099990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-24-26-04
  • eCl@ss 9.0: 27-24-26-04
  • ETIM 8.0: EC001599
  • ETIM 9.0: EC001599
  • Packaging type: Box
  • Product Group: 15 (I/O System)
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: inputs/outputs: 8 x CAGE CLAMP®
  • Connection type 1: Inputs/outputs
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1|75980-60-8|80-05-7
  • REACH Candidate List Substance: 4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): 455422aa-0af7-4236-bce5-56a64061e77a
  • SCIP notification number (Belgium): d08aa233-6cb6-41d9-a0bc-f32f7a9c1388
  • SCIP notification number (Bulgaria): 5e00a515-53cf-4b0f-b72e-d849e2b82d4d
  • SCIP notification number (Czech Republic): 297355ca-ec16-4ed8-96d9-46703f222b73
  • SCIP notification number (Denmark): a5c890cd-d642-467f-ad02-01fc6bd03c89
  • SCIP notification number (Finland): bc722cdd-62f7-4cb5-a606-7bd2aebdff8a
  • SCIP notification number (France): c3eec32c-a4c6-4661-a4ed-1bd4e9cec74a
  • SCIP notification number (Germany): 1d5a8811-eed2-488d-bed9-fa61f31ce19b
  • SCIP notification number (Hungary): caf38cc2-d5a8-4317-b257-09a4814898f5
  • SCIP notification number (Italy): a6ec395a-a99f-4b96-b6f3-ac92b6b9eac3
  • SCIP notification number (Netherlands): 60969300-4247-46b1-af2c-2d7bdf58a56a
  • SCIP notification number (Poland): 5018c2ce-0c5c-4115-bc62-41290fdb653e
  • SCIP notification number (Romania): df068cd7-6fb3-4b09-9e10-1f9e1189b9d8
  • SCIP notification number (Sweden): 47f6856c-9e40-4127-8008-6375a41117e0

Environmental requirements

  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -25 … +85 °C
  • EMC emission of interference: per EN 61000-6-3, marine applications
  • EMC immunity to interference: per EN 61000-6-2, marine applications
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal right, horizontal top, vertical top and vertical bottom
  • Operating altitude: 0 … 2000 m / 0 … 6562 ft
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (without condensation): 95%
  • Shock resistance: 15g per IEC 60068-2-27
  • Vibration resistance: 4g per IEC 60068-2-6

Explosion protection

  • Ex standard: EN IEC 60079-0, -7, -11
  • Identification: ATEX
    II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
    II (1) D [Ex ia Da] IIIC
    I (M1) [Ex ia Ma] I|IECEx/ INMETRO
    Ex ec [ia Ga] IIC T4 Gc
    [Ex ia Da] IIIC
    [Ex ia Ma] I|cULus (Zone classified)
    Cl I Zn 2 AEx nA [ia Ga] IIC T4 Gc
    Cl I Zn 2 AEx nA [ia IIIC] IIC T4 Gc
    Ex nA [ia Ga] IIC T4 Gc X
    Ex nA [ia IIIC] IIC T4 Gc X|cULus (Devision classified)
    Class I, Div. 2, Group A B C D, T4
  • Reactances (note): Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)
  • Reactances Ex ia I: Lo = 100 mH; Co = 2.95 µF
  • Reactances Ex ia IIA: Lo = 100 mH; Co = 2.28 µF
  • Reactances Ex ia IIB: Lo = 100 mH; Co = 552 nF
  • Reactances Ex ia IIC: Lo = 61 mH; Co = 64 nF
  • Safety-relevant data (circuit): Uo = 27.3 V; Io = 23 mA; Po = 157 mW; linear characteristic curve

Functional Safety

  • Achievable risk reduction: SIL 3 per IEC 61508; SIL 3 per IEC 61511; SIL 3 per IEC 62061; Cat. 4, PL e per EN ISO 13849
  • Safety standards: IEC 61508; IEC 62061; EN ISO 13849; IEC 61511

Material data

  • Conformity marking: CE
  • Fire load: 2.021MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 92g

Mechanical data

  • Mounting type: DIN-35 rail

Notes

  • Note: The PROFIsafe Input Module must only be operated using an Ex i 24 VDC power supply (e.g., 750-606, 750-625/000-001)! General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals! To protect the module against surge voltages (surge protection per IEC 61000-4-5), a filter module (750-626 or 750-624) or an external surge filter must be used upstream of the Ex i 24 VDC power supply. Reference the product manual for further information!

Physical data

  • Depth: 67.8 mm / 2.669 inches
  • Depth from upper-edge of DIN-rail: 60.6 mm / 2.386 inches
  • Height: 100 mm / 3.937 inches
  • Width: 24 mm / 0.945 inches

Technical data

  • Configuration options: PROFIsafe address adjustable via DIP switch or engineering software
  • Current carrying capacity (power jumper contacts): 1A
  • Current consumption (5 V system supply): 145mA
  • Current consumption, field supply (module with no external load): 20mA
  • Indicators: LED (A-D) green/red: Status/Error I1 … I4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
  • Input characteristic: clock sensitive|Type 1 per IEC 61131
  • Input current per channel for signal (1) typ.: 3mA
  • Input filter: 0 … 200 ms (parameterizable in steps)
  • Input filter: parametrizable (channel by channel): Yes
  • Intrinsically safe Ex i: Yes
  • Isolation: 300 VAC system/field
  • Item description: Intrinsically Safe 4-Channel Digital Input; 24 VDC; PROFIsafe V 2.0 iPar
  • Number of digital inputs: 4
  • Number of incoming power jumper contacts: 2
  • Number of outgoing power jumper contacts: 2
  • Output current per channel: 0.005A
  • Power consumption Pmax.: 3 W
  • Power loss Pl: 1.27 W
  • Protocols: PROFIsafe V2
  • Sensor connection: 4 x (Fail-safe input with test pulse)
  • Short-circuit current: ≤ 25 mA
  • Signal frequency (max.): 50Hz
  • Signal type: Digital
  • Signal type (voltage): 24 VDC
  • Supply voltage (field): 24 VDC; (Ex i power supply: Uo = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
  • Supply voltage (system): 5 VDC; via data contacts
  • Total number of channels (module): 4