Fail-safe / safety DC digital input slice unit module - Safety SIL3/Cat4/Ple or SIL2/Cat2/Pld - WAGO (750 series) - 8FDI 24V PROFIsafe - 8I/O [8DI (8 x digital inputs (fail-safe inputs with test pulse; type-1; clock sensitive; 24Vdc))] - with PROFIBUS + PROFINET + PROFIsafe communication capability - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (24mm width) - IP20 - rated for 0°C...+55°C ambient - compliant with IEC61508-1; IEC61508-2; IEC61508-3; IEC61508-4; IEC61508-5; IEC61508-6; IEC61508-7; EN ISO13849-1; EN 62061 - equivalent to 750662000004
Specifications
- Primary brand: WAGO
- Functions: Fail-safe / safety DC digital input slice unit module|Configuration options|- PROFIsafe address adjustable via DIP switch or engineering software
- Supply voltage (DC): 5Vdc (supplied by system)|18-31.2Vdc (SELV/PELV) adjustable suppl. to field sensing devices
- Display: LED (A-D) green/red -- Status/Error I1...I8|LED (E) red -- Group error|LED (F-H) green/red -- Diagnostics
- Connection type: spring CAGE CLAMP connections
- Mounting mode: DIN-35 rail
- Digital inputs: 8 x digital inputs (fail-safe inputs with test pulse; type-1; clock sensitive; 24Vdc)
- Dimensions: H100mm x W24mm x D67.8mm
- Net Width (mm): 24mm
- Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
- Ambient air temperature for operation: 0°C...+55°C
- Ambient air temperature for storage: -25°C...+85°C
- Humidity: 95% relative humidity (RH; non-condensing)
- Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g
- Current consumption: 120mA (5Vdc; system supply)|35mA (field supply; no external load)
- GTIN code: 4066966334081
- ETIM code: EC001599
- Customs Tariff Number: 85389099990
- Order code / Manufacturer SKU: 750-662/000-004
- Manufacturer product status: Commercialized
- Equivalent to: 750662000004
- EAN code: 4066966213355
- Compliant with standard(s): IEC61508-1|IEC61508-2|IEC61508-3|IEC61508-4|IEC61508-5|IEC61508-6|IEC61508-7|EN ISO13849-1|EN 62061|CE|EMC immunity to interference|- Per EN 61000-6-2|- marine applications|- EN 61000-6-7 (FS)|EMC emission of interference|- Per EN 61000-6-3|- EN 61000-6-4|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194|- PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV 12.1297 X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|Approvals for functional safety|- Prod. Safety Funct. Safety - TUV Rheinland Industrie Service GmbH - certificate No. 968/EZ 247.18/21|- Profi-Safe - Siemens AG/ComDeC - certificate Z20293|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
- Class: Safety SIL3/Cat4/Ple or SIL2/Cat2/Pld
- Location of origin: Germany
- Degree of pollution: 2
- Level 1 category: Safety components
- Level 2 category: Safety I-O Units
- Product title: Fail-safe / safety DC digital input slice unit module - WAGO
Commercial data
- Country of origin: DE
- Customs tariff number: 85389099990
- ECCN: NO US CLASSIFICATION
- ETIM 8.0: EC001599
- ETIM 9.0: EC001599
- GTIN: 4066966334081
- Packaging type: Box
- PU (SPU): 1 pcs
Connection data
- Connectable conductor materials: Copper
- Connection technology: inputs/outputs: 16 x CAGE CLAMP®
- Connection type 1: Inputs/outputs
- Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Strip length: 8 … 9 mm / 0.31 … 0.35 inches
Digitale Ausgänge
- Signal type: Digital
- Signal type (voltage): 24 VDC
Digitale Eingänge
- Input characteristic: clock sensitive|Type 1 per IEC 61131
- Input current per channel for signal (1) typ.: 3mA
- Number of digital inputs: 8
- Sensor connection: 8 x (Fail-safe input with test pulse)
- Signal frequency (max.): 50Hz
- Signal type: Digital
- Signal type (voltage): 24 VDC
Digitale Taktausgänge
- Output current per channel: 0.1A
- Signal type: Digital
- Signal type (voltage): 24 VDC
Environmental Product Compliance
- CAS-No.: 1303-86-2|1317-36-8|693-98-1|7439-92-1|80-05-7
- REACH Candidate List Substance: 2-methylimidazole|4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide
- RoHS Compliance Status: Compliant,With Exemption
- RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
- SCIP notification number (Austria): bffe983b-203b-4112-84e6-89e6790923df
- SCIP notification number (Belgium): fdf24570-a7d3-4cfe-909a-6340d695de4e
- SCIP notification number (Bulgaria): 89eb339d-4807-4740-a943-6999d5b1e756
- SCIP notification number (Czech Republic): 3e8c52cc-5320-4926-b0f5-a5c03799aa8e
- SCIP notification number (Denmark): da2def3e-6cf0-4229-9ec7-4e2ae2d0c9fd
- SCIP notification number (Finland): 1bf63bc6-2177-4275-8258-3fe7591fc421
- SCIP notification number (France): 98cdfc68-e272-46e0-bcc1-b64e15222c92
- SCIP notification number (Germany): d34568be-ca53-43a8-86e5-30be56a7996b
- SCIP notification number (Hungary): a835e7ac-30d8-4889-9d51-5234343a99f1
- SCIP notification number (Italy): 8589371e-4c86-48b8-be1e-0276fd86a30b
- SCIP notification number (Netherlands): b7519976-8bca-4637-89f1-c624a9df6bc2
- SCIP notification number (Poland): 7d23aca3-e1a6-4509-9585-0eb1edb3383e
- SCIP notification number (Romania): 92f18abe-83da-473a-894c-6aa43f726690
- SCIP notification number (Sweden): e5c053d8-6388-49a0-ba09-a08cd3057cbe
Environmental requirements
- Ambient temperature (operation): 0 … +55 °C
- Ambient temperature (storage): -25 … +85 °C
- EMC emission of interference: per EN 61000-6-3, -4; marine applications
- EMC immunity to interference: per EN 61000-6-2, marine applications, EN 61000-6-7 (FS)
- Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
- Mounting position: Horizontal left, horizontal right, horizontal top, vertical top and vertical bottom
- Operating altitude: 0 … 2000 m / 0 … 6562 ft
-
Permissible H2S contaminant concentration at a relative humidity
75 %: 10ppm -
Permissible SO2 contaminant concentration at a relative humidity
75 %: 25ppm - Pollution degree: 2 per IEC 61131-2
- Protection type: IP20
- Relative humidity (without condensation): 95%
- Shock resistance: 15g per IEC 60068-2-27
- Vibration resistance: 4g per IEC 60068-2-6
Functional Safety
- Achievable safety classes: SIL 3; Category 4, PLe (two-channel); SIL 2; Category 2; PLd (one-channel)
- Interface types according to ZVEI (inputs): Drain; A, C0, C1, C2, C3
- Safety standards: IEC 61508-1 … -7; EN ISO 13849-1; EN 62061
General technical data
- Configuration options: PROFIsafe address adjustable via DIP switch or engineering software
- Indicators: LED (A-D) green/red: Status/Error I1 … I8; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
- Pluggable connector: fixed
- Protocols: PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET)
- Total number of channels (module): 8
Material data
- Conformity marking: CE
- Fire load: 1.985MJ
- Housing material: Polycarbonate; polyamide 6.6
- Weight: 96.5g
Mechanical data
- Mounting type: DIN-35 rail
- Pluggable connector: fixed
Physical data
- Depth: 67.8 mm / 2.669 inches
- Depth from upper-edge of DIN-rail: 60.6 mm / 2.386 inches
- Height: 100 mm / 3.937 inches
- Width: 24 mm / 0.945 inches
Technical data
- Current carrying capacity (power jumper contacts): 10A
- Current consumption (5 V system supply): 120mA
- Current consumption, field supply (module with no external load): 35mA
- Number of incoming power jumper contacts: 2
- Number of outgoing power jumper contacts: 2
- Supply voltage (field): 24 VDC, SELV/PELV (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)
- Supply voltage (system): 5 VDC; via data contacts