{"product_id":"wago-750-634","title":"Wago - 750-633","description":"\u003cp\u003eIntrinsically-safe counter module - WAGO (750 series) - Up\/Down Counter; Ex i - 2I\/O [1DI (1 x digital input (counter; 32-bits)) + 1DO (1 x digital output (24Vdc))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (24mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750633\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Intrinsically-safe counter module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 5Vdc (supplied by system)|24Vdc fixed suppl. to field sensing devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (A\/D\/E) green -- U\/D (Gate) \/ DO \/ CLOCK|LED (B\/F) red -- Error U\/D (Gate) \/ Error CLOCK|\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e spring CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital inputs:\u003c\/strong\u003e 1 x digital input (counter; 32-bits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs:\u003c\/strong\u003e 1 x digital output (24Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W24mm x D67.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 24mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -25°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 25mA (5Vdc; system supply)|31mA (field supply; no external load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 2.2W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001601\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation\/losses:\u003c\/strong\u003e 1.7W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 750-633\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 750633\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821386926\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|EMC immunity to interference|- EN 61000-6-2|- marine applications|EMC emission of interference|- EN 61000-6-3|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-CTM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Ex-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Ex-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 22-2219060|- DNV - DNV GL SE - DNV-CG-0339 \/ Aug.2021 - certificate TAA0000194|- KR - Korean Register of Shipping - certificate KR HMB05880-AC001|- LR - Lloyds Register EMEA - certificate LR22180952TA|- PRS - Polski Rejestr Statkow - certificate TE\/1101\/880590\/23|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- AEx - UL International Germany GmbH - UL 60079 - certificate E480271|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV12ATEX106032X (Ex ec[iaGa] IIC T4 Gc \/ [Ex iaDa] IIIC \/ [Ex iaMa] I)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000211 (Ex ec[iaGa] IIC T4 Gc \/ [Ex iaDa] IIIC \/ [Ex iaMa] I)|- IECEx - TUV Nord Cert GmbH - IEC 60079 - certificate IECEx TUN12.0039X (Ex ec[iaGa] IIC T4 Gc \/ [Ex iaDa] IIIC \/ [Ex iaMa] I)|- INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV_14.1911_X|- UKEx - Element Materials Technology UK - certificate EMA21UKEX0069X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Programmable Logic Controllers \u0026amp; components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e I-O Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Intrinsically-safe counter module - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001601\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001601\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 15 (I\/O System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: inputs\/outputs:\u003c\/strong\u003e 16 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Inputs\/outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 5b4703c5-63a4-4a2f-840e-875112670b16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 0dfd5047-b7df-4e54-811a-a9b844981321\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -25 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61000-6-3, marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61000-6-2, marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 … 2000 m \/ 0 … 6562 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 4g per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExplosion protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx standard:\u003c\/strong\u003e EN IEC 60079-0, -7, -11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentification:\u003c\/strong\u003e ATEX\u003cbr\u003eII 3 (1) G Ex ec [ia Ga] IIC T4 Gc\u003cbr\u003eII (1) D [Ex ia Da] IIIC\u003cbr\u003eI (M1) [Ex ia Ma] I|IECEx\/ INMETRO\u003cbr\u003eEx ec [ia Ga] IIC T4 Gc\u003cbr\u003e[Ex ia Da] IIIC\u003cbr\u003e[Ex ia Ma] I|cULus (Zone classified)\u003cbr\u003eCl I Zn 2 AEx nA [ia Ga] IIC T4 Gc\u003cbr\u003eCl I Zn 2 AEx nA [ia IIIC] IIC T4 Gc\u003cbr\u003eEx nA [ia Ga] IIC T4 Gc X\u003cbr\u003eEx nA [ia IIIC] IIC T4 Gc X|cULus (Devision classified)\u003cbr\u003eClass I, Div. 2, Group A B C D, T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances (note):\u003c\/strong\u003e Reactances without accounting for the concurrence of capacitance (C\u003csub\u003eo\u003c\/sub\u003e) and inductance (L\u003csub\u003eo\u003c\/sub\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia I inputs:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 100 mH; C\u003csub\u003eo\u003c\/sub\u003e = 38 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia I output:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 26 mH; C\u003csub\u003eo\u003c\/sub\u003e = 3.6 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia IIA inputs:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 100 mH; C\u003csub\u003eo\u003c\/sub\u003e = 36 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia IIA output:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 18 mH; C\u003csub\u003eo\u003c\/sub\u003e = 2.2 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia IIB inputs:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 100 mH; C\u003csub\u003eo\u003c\/sub\u003e = 9 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia IIB output:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 10 mH; C\u003csub\u003eo\u003c\/sub\u003e = 683 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia IIC inputs:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 100 mH; C\u003csub\u003eo\u003c\/sub\u003e = 1.4 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances of Ex ia IIC output:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 0.5 mH; C\u003csub\u003eo\u003c\/sub\u003e = 88 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety data (input):\u003c\/strong\u003e U\u003csub\u003eo\u003c\/sub\u003e = 12 V; I\u003csub\u003eo\u003c\/sub\u003e = 13.5 mA; P\u003csub\u003eo\u003c\/sub\u003e = 40.5 mW; linear characteristic curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety data (output):\u003c\/strong\u003e U\u003csub\u003eo\u003c\/sub\u003e = 26.8 V; I\u003csub\u003eo\u003c\/sub\u003e = 96.7 mA; P\u003csub\u003eo\u003c\/sub\u003e = 648 mW; linear characteristic curve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 2.035MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 88.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cp\u003eThe up\/down counter must only be operated via 24 VDC Ex i XTR power supply!\u003c\/p\u003e\n\u003cp\u003eGeneral information (e.g., installation regulations) on explosion protection is available in the WAGO I\/O System 750 manuals!\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 67.8 mm \/ 2.669 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 60.6 mm \/ 2.386 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24 mm \/ 0.945 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounter depth:\u003c\/strong\u003e 32bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent carrying capacity (power jumper contacts):\u003c\/strong\u003e 1A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption (5 V system supply):\u003c\/strong\u003e 25mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption, field supply (module with no external load):\u003c\/strong\u003e 31mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData width:\u003c\/strong\u003e 1 x 32-bit data, 1 x 8-bit status\/diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (A, D, E) green: U\/D (Gate), DO, CLOCK; LED (B, F) red: Error U\/D (Gate), Error CLOCK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput filter:\u003c\/strong\u003e 10 µs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput resistance (max.):\u003c\/strong\u003e 1000Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal resistance R\u003csub\u003ei\u003c\/sub\u003e:\u003c\/strong\u003e 285Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsically safe Ex i:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 300 VAC system\/supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eItem description:\u003c\/strong\u003e Up\/Down Counter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of counters:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of digital outputs:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of incoming power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of outgoing power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-circuit voltage:\u003c\/strong\u003e 8.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption P\u003csub\u003emax.\u003c\/sub\u003e:\u003c\/strong\u003e 2.2 W (sensor load: 8.2 mA + actuator load: 45 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower loss P\u003csub\u003el\u003c\/sub\u003e:\u003c\/strong\u003e 1.7 W (sensor load: 8.2 mA + actuator load: 45 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor supply U\u003csub\u003eV\u003c\/sub\u003e:\u003c\/strong\u003e 8.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit current:\u003c\/strong\u003e 8.2 mA (+\/- 5 %)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal current (0):\u003c\/strong\u003e 1.2mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal current (1):\u003c\/strong\u003e 2.1mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (field):\u003c\/strong\u003e 24 VDC; (Ex i power supply: U\u003csub\u003eo\u003c\/sub\u003e = max. 26.8 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 5 VDC; via data contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency:\u003c\/strong\u003e 20 Hz … 50 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching hysteresis:\u003c\/strong\u003e 0.2mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695656779913,"sku":"7500633","price":889.8,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-750-634","provider":"US Automation Controls","version":"1.0","type":"link"}