Intrinsically-safe counter module - WAGO (750 series) - Up/Down Counter; Ex i - 2I/O [1DI (1 x digital input (counter; 32-bits)) + 1DO (1 x digital output (24Vdc))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (24mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750633

Specifications

  • Primary brand: WAGO
  • Functions: Intrinsically-safe counter module
  • Supply voltage (DC): 5Vdc (supplied by system)|24Vdc fixed suppl. to field sensing devices
  • Display: LED (A/D/E) green -- U/D (Gate) / DO / CLOCK|LED (B/F) red -- Error U/D (Gate) / Error CLOCK|
  • Connection type: spring CAGE CLAMP connections
  • Mounting mode: DIN-35 rail
  • Digital inputs: 1 x digital input (counter; 32-bits)
  • Digital outputs: 1 x digital output (24Vdc)
  • Dimensions: H100mm x W24mm x D67.8mm
  • Net Width (mm): 24mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Ambient air temperature for storage: -25°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g
  • Current consumption: 25mA (5Vdc; system supply)|31mA (field supply; no external load)
  • Power consumption: 2.2W
  • ETIM code: EC001601
  • Customs Tariff Number: 85389099990
  • eClass code: 27-24-26-05
  • Power dissipation/losses: 1.7W
  • Order code / Manufacturer SKU: 750-633
  • Manufacturer product status: Commercialized
  • Equivalent to: 750633
  • EAN code: 4050821386926
  • Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-2|- marine applications|EMC emission of interference|- EN 61000-6-3|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-CTM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Ex-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Ex-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 22-2219060|- DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194|- KR - Korean Register of Shipping - certificate KR HMB05880-AC001|- LR - Lloyds Register EMEA - certificate LR22180952TA|- PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- AEx - UL International Germany GmbH - UL 60079 - certificate E480271|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV12ATEX106032X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000211 (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)|- IECEx - TUV Nord Cert GmbH - IEC 60079 - certificate IECEx TUN12.0039X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)|- INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV_14.1911_X|- UKEx - Element Materials Technology UK - certificate EMA21UKEX0069X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Intrinsically-safe counter module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85389099990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-24-26-05
  • eCl@ss 9.0: 27-24-26-05
  • ETIM 8.0: EC001601
  • ETIM 9.0: EC001601
  • Packaging type: Box
  • Product Group: 15 (I/O System)
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: inputs/outputs: 16 x CAGE CLAMP®
  • Connection type 1: Inputs/outputs
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1
  • REACH Candidate List Substance: Diboron trioxide|Lead|Lead monoxide
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Bulgaria): 5b4703c5-63a4-4a2f-840e-875112670b16
  • SCIP notification number (Czech Republic): 0dfd5047-b7df-4e54-811a-a9b844981321

Environmental requirements

  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -25 … +85 °C
  • EMC emission of interference: per EN 61000-6-3, marine applications
  • EMC immunity to interference: per EN 61000-6-2, marine applications
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
  • Operating altitude: 0 … 2000 m / 0 … 6562 ft
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (without condensation): 95%
  • Shock resistance: 15g per IEC 60068-2-27
  • Vibration resistance: 4g per IEC 60068-2-6

Explosion protection

  • Ex standard: EN IEC 60079-0, -7, -11
  • Identification: ATEX
    II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
    II (1) D [Ex ia Da] IIIC
    I (M1) [Ex ia Ma] I|IECEx/ INMETRO
    Ex ec [ia Ga] IIC T4 Gc
    [Ex ia Da] IIIC
    [Ex ia Ma] I|cULus (Zone classified)
    Cl I Zn 2 AEx nA [ia Ga] IIC T4 Gc
    Cl I Zn 2 AEx nA [ia IIIC] IIC T4 Gc
    Ex nA [ia Ga] IIC T4 Gc X
    Ex nA [ia IIIC] IIC T4 Gc X|cULus (Devision classified)
    Class I, Div. 2, Group A B C D, T4
  • Reactances (note): Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)
  • Reactances of Ex ia I inputs: Lo = 100 mH; Co = 38 µF
  • Reactances of Ex ia I output: Lo = 26 mH; Co = 3.6 µF
  • Reactances of Ex ia IIA inputs: Lo = 100 mH; Co = 36 µF
  • Reactances of Ex ia IIA output: Lo = 18 mH; Co = 2.2 µF
  • Reactances of Ex ia IIB inputs: Lo = 100 mH; Co = 9 µF
  • Reactances of Ex ia IIB output: Lo = 10 mH; Co = 683 nF
  • Reactances of Ex ia IIC inputs: Lo = 100 mH; Co = 1.4 µF
  • Reactances of Ex ia IIC output: Lo = 0.5 mH; Co = 88 nF
  • Safety data (input): Uo = 12 V; Io = 13.5 mA; Po = 40.5 mW; linear characteristic curve
  • Safety data (output): Uo = 26.8 V; Io = 96.7 mA; Po = 648 mW; linear characteristic curve

Material data

  • Color: blue
  • Conformity marking: CE
  • Fire load: 2.035MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 88.2g

Mechanical data

  • Mounting type: DIN-35 rail

Notes

  • Note:

    The up/down counter must only be operated via 24 VDC Ex i XTR power supply!

    General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals!

Physical data

  • Depth: 67.8 mm / 2.669 inches
  • Depth from upper-edge of DIN-rail: 60.6 mm / 2.386 inches
  • Height: 100 mm / 3.937 inches
  • Width: 24 mm / 0.945 inches

Technical data

  • Counter depth: 32bits
  • Current carrying capacity (power jumper contacts): 1A
  • Current consumption (5 V system supply): 25mA
  • Current consumption, field supply (module with no external load): 31mA
  • Data width: 1 x 32-bit data, 1 x 8-bit status/diagnostics
  • Indicators: LED (A, D, E) green: U/D (Gate), DO, CLOCK; LED (B, F) red: Error U/D (Gate), Error CLOCK
  • Input filter: 10 µs
  • Input resistance (max.): 1000Ω
  • Internal resistance Ri: 285Ω
  • Intrinsically safe Ex i: Yes
  • Isolation: 300 VAC system/supply
  • Item description: Up/Down Counter
  • Number of counters: 1
  • Number of digital outputs: 1
  • Number of incoming power jumper contacts: 2
  • Number of outgoing power jumper contacts: 2
  • Open-circuit voltage: 8.2V
  • Output voltage: 24 VDC
  • Power consumption Pmax.: 2.2 W (sensor load: 8.2 mA + actuator load: 45 mA)
  • Power loss Pl: 1.7 W (sensor load: 8.2 mA + actuator load: 45 mA)
  • Sensor supply UV: 8.2V
  • Short-circuit current: 8.2 mA (+/- 5 %)
  • Signal current (0): 1.2mA
  • Signal current (1): 2.1mA
  • Supply voltage (field): 24 VDC; (Ex i power supply: Uo = max. 26.8 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
  • Supply voltage (system): 5 VDC; via data contacts
  • Switching frequency: 20 Hz … 50 kHz
  • Switching hysteresis: 0.2mA