Standard analog input slice unit module with double isolation - for 3-phase pwr. measurement - WAGO (750 series) - 3-PHASE POM; 690VAC 1A - 7I/O [7AI (3 x analog inputs (3-phase voltage measurement; 400Vac / 690Vac / 45...65Hz / 24-bits conversion) + 4 x analog inputs (differential current measurement; 1A))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750495
Specifications
- Primary brand: WAGO
- Functions: Standard analog input slice unit module
- Design: double isolation|for 3-phase pwr. measurement
- Supply voltage (DC): 5Vdc (supplied by system)
- Display: LED (A) green -- Communication|LED (B-G) red -- Error L1/Override in Current Measurement Path (display)/Undervoltage in Voltage Measurement Path (display)/Error L2/Error L3/Override in Voltage Measurement Path (display)|LED (H) yellow -- Interchange in Phase Sequence L1-L2-L3
- Connection type: spring CAGE CLAMP connections
- Mounting mode: DIN-35 rail
- Analog inputs: 3 x analog inputs (3-phase voltage measurement; 400Vac / 690Vac / 45...65Hz / 24-bits conversion)|4 x analog inputs (differential current measurement; 1A)
- Measurement accuracy: AC current/voltage; +-0.5% (measuring error)
- Dimensions: H100mm x W24mm x D67.8mm
- Net Width (mm): 12mm
- Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
- Ambient air temperature for operation: 0°C...+55°C
- Ambient air temperature for storage: -40°C...+85°C
- Humidity: 95% relative humidity (RH; non-condensing)
- Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g
- Current consumption: 100mA (5Vdc; system supply)
- ETIM code: EC001596
- Customs Tariff Number: 85389099990
- eClass code: 27-24-26-05
- Order code / Manufacturer SKU: 750-495
- Manufacturer product status: Commercialized
- Equivalent to: 750495
- EAN code: 4050821548256
- Compliant with standard(s): Safety and protection|Insulation coordination per EN/UL 61010-2-201 with N connection|- Insulation type -- Reinforced insulation|- Note on system voltage -- The system voltage is derived from the line-to-neutral voltage for common MAINS supply systems.|- Overvoltage category -- III|- System voltage -- ≤300V|Insulation coordination per EN/UL 61010-2-201 without N connection|- Insulation type -- Double isolation (basic isolation and supplementary isolation by impedance/current measurement transformer)|Safe isolation from the adjacent SELV/PELV modules must be ensured. The product manual contains the types of isolation|to adjacent modules in section "Isolation to Adjacent I/O Modules per EN/UL 61010 2-201." Without double or reinforced isolation|the 750-495/000-00x Power Measurement Module must not be placed directly next to SELV/PELV modules.|The 750-616/040-000 Distance Module must be used under such conditions.|- Note on system voltage -- the module' N connector must not be connected to ensure safe insulation. The system voltage|corresponds to the line conductor/neutral conductor voltage which was derived from standard power supply systems|- Overvoltage category -- III|- System voltage -- ≤600V|CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-3|General approvals|- EAC - GZO Almaty Standart - TP TC 004/2011 - certificate EAC CoC 03080|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-AIM750|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- BSH - Bundesamt fuer Seeschifffahrt und Hydrographie - certificate 1104|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
- Location of origin: Germany
- Degree of pollution: 2
- Level 1 category: Automation components
- Level 2 category: Programmable Logic Controllers & components
- Level 3 category: I-O Units
- Product title: Standard analog input slice unit module - double isolation - WAGO
Commercial data
- Country of origin: DE
- Customs tariff number: 85389099990
- ECCN: NO US CLASSIFICATION
- eCl@ss 10.0: 27-24-26-05
- eCl@ss 9.0: 27-24-26-05
- ETIM 8.0: EC001596
- ETIM 9.0: EC001596
- Packaging type: Box
- Product Group: 15 (I/O System)
- PU (SPU): 1 pcs
Connection data
- Connectable conductor materials: Copper
- Connection technology: inputs/outputs: 12 x CAGE CLAMP®
- Connection type 1: Inputs/outputs
- Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Note (conductor cross-section): Solid conductor: 20 … 14 AWG (UL); Fine-stranded conductor: 20 … 16 AWG (UL) These values refer exclusively to the mechanical connection capacity of the clamping points. When the applications/devices are operated in locations covered by UL, only solid conductor with 20 … 14 AWG and fine-stranded conductor with 20 … 16 AWG are permitted.
- Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Strip length: 8 … 9 mm / 0.31 … 0.35 inches
Environmental Product Compliance
- CAS-No.: 1303-86-2|1317-36-8|7439-92-1
- REACH Candidate List Substance: Diboron trioxide|Lead|Lead monoxide
- RoHS Compliance Status: Compliant,With Exemption
- RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
- SCIP notification number (Bulgaria): 0ab7d5e9-43fc-483b-91d0-6c34e6674317
- SCIP notification number (Czech Republic): 5b4d8695-cd28-4784-a429-8d4505f65451
Environmental requirements
- Ambient temperature (operation): 0 … +55 °C
- Ambient temperature (storage): -40 … +85 °C
- EMC emission of interference: per EN 61000-6-3
- EMC immunity to interference: per EN 61000-6-2
- Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
- Mounting position: Horizontal left, horizontal up, vertical top and vertical bottom
- Operating altitude: 0 … 2000 m / 0 … 6562 ft
-
Permissible H2S contaminant concentration at a relative humidity
75 %: 10ppm -
Permissible SO2 contaminant concentration at a relative humidity
75 %: 25ppm - Pollution degree: 2 per EN 60664-1
- Protection type: IP20
- Relative humidity (without condensation): 95%
- Shock resistance: 15g per IEC 60068-2-27
- Vibration resistance: 4g per IEC 60068-2-6
Material data
- Color: light gray
- Conformity marking: CE
- Fire load: 2.001MJ
- Housing material: Polycarbonate; polyamide 6.6
- Weight: 90.7g
Mechanical data
- Mounting type: DIN-35 rail
Physical data
- Depth: 67.8 mm / 2.669 inches
- Depth from upper-edge of DIN-rail: 60.6 mm / 2.386 inches
- Height: 100 mm / 3.937 inches
- Width: 24 mm / 0.945 inches
Safety and protection
- Insulation coordination per EN/UL 61010-2-201 with N connection - Insulation type: Reinforced insulation
- Insulation coordination per EN/UL 61010-2-201 with N connection - Note on system voltage: The system voltage is derived from the line-to-neutral voltage for common MAINS supply systems.
- Insulation coordination per EN/UL 61010-2-201 with N connection - Overvoltage category: III
- Insulation coordination per EN/UL 61010-2-201 with N connection - System voltage: ≤300 V
- Insulation coordination per EN/UL 61010-2-201 without N connection - Insulation type: Double isolation (basic isolation and supplementary isolation by impedance/current measurement transformer) Safe isolation from the adjacent SELV/PELV modules must be ensured. The product manual contains the types of isolation to adjacent modules in section “Isolation to Adjacent I/O Modules per EN/UL 61010 2-201.” Without double or reinforced isolation, the 750-495/000-00x Power Measurement Module must not be placed directly next to SELV/PELV modules. Under such conditions, the 750-616 Distance Module must be used.
- Insulation coordination per EN/UL 61010-2-201 without N connection - Note on system voltage: To ensure safe insulation, the module's N connector must not be connected. The system voltage corresponds to the line conductor/neutral conductor voltage, which was derived from standard power supply systems
- Insulation coordination per EN/UL 61010-2-201 without N connection - Overvoltage category: III
- Insulation coordination per EN/UL 61010-2-201 without N connection - System voltage: ≤ 600 V
- Measurement category per EN/UL 61010-2-030: CAT III
- Test voltage - Rated impulse withstand voltage: System/field side: 5.0 kV (EN 60870-2-1 / Class VW3) 6.4 kV (EN/UL 61010-1)
- Test voltage - Test voltage: 3.51 kVAC, 50/60 Hz, 1 min.
Technical data
- Calculated values: Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD
- Current consumption (5 V system supply): 100mA
- Current path input resistance (typ.): 22 mΩ
- Data width: 2 x 128-bit data; 2 x 64-bit control/status
- Frequency range (harmonics analysis): 0 … 3300 Hz
- Frequency range (mains frequency): 50/60 Hz
- Indicators: LED (A) green: Communication; LED (B-G) red: Error L1, Override in Current Measurement Path (display), Undervoltage in Voltage Measurement Path (display), Error L2, Error L3, Override in Voltage Measurement Path (display); LED (H) yellow: Interchange in Phase Sequence L1-L2-L3
- Limit frequency: 15.9kHz
- Measurement current (max.): 1 A
- Measurement cycle time: Adjustable for arithmetic mean value, Min_Max_Values
- Measurement error (reference temperature): 23°C
- Measurement error, deviation (max.) from the upper-range value: 0.5%
- Measurement method: True RMS measurement
- Note on common mains supply systems: ULL up to 690°V is possible under special conditions (see manual).
- Number of measurement inputs: 7 (3 voltage measurement inputs, 4 differential current measurement inputs)
- Permissible common mains supply systems: Three-phase, four-wire system: max. 277/480 VAC; Three-phase, three-wire system: max. 600 VAC (UL)
- Reference for measurement error: AC current/voltage
- Resolution [bit]: 24bits
- Signal form: Sinusoidal signals (taking the cutoff frequency into account)
- Signal type: Power measurement
- Supply voltage (system): 5 VDC; via data contacts
- Upper-range value for the measurement accuracy: 400/690 V