{"product_id":"wago-750-563","title":"Wago - 750-562","description":"\u003cp\u003eStandard analog output slice unit module - WAGO (750 series) - 2AO; 0-10V\/+-10Vdc; 16-bits - 2I\/O [2AO (2 x analog outputs (0-10Vdc \/ -10...+10Vdc \/ 16-bits \/ 5ms conversion time; 2-wire \/ 4-wire))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750562\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Standard analog output slice unit module|Configuration options|- WAGO-I\/O-CHECK|- e!COCKPIT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 5Vdc (supplied by system)|20.4-28.8Vdc adjustable suppl. to field sensing devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (A\/C) green -- Function AO 1 \/ AO 2|LED (B\/D) red -- Error AO 1 \/ AO 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e spring CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog outputs:\u003c\/strong\u003e 2 x analog outputs (0-10Vdc \/ -10...+10Vdc \/ 16-bits \/ 5ms conversion time; 2-wire \/ 4-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e +-0.05% (measuring error)|+-100ppm (temperature error)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W12mm x D69.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 12mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 125mA (5Vdc; system supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4045454710316\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 750-562\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 750562\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4045454710316\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|EMC immunity to interference|- EN 61131-2|EMC emission of interference|- EN 61131-2|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-AOM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST\/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- UKEx - WAGO GmbH \u0026amp; Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Programmable Logic Controllers \u0026amp; components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e I-O Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Standard analog output slice unit module - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4045454710316\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 15 (I\/O System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: inputs\/outputs:\u003c\/strong\u003e 8 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Inputs\/Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 25550-51-0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 4-Methyl-1,2-cyclohexanedicarboxylic anhydride\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e bac4dd5b-c1fb-423a-bb1d-6b3e30455d03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 12dec2ec-b5fe-4b73-b844-b54a4d52feb2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e f776a0df-ce45-4755-9f58-020f362b2308\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e ada9799a-e7d1-4e2c-a0f3-136e86f3eeab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 9eec1bff-8eee-4c55-8e0b-7009510bb199\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 24a70d97-24fc-45e8-b4dd-daeaf1904841\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e a0758b00-b6a0-4108-8d02-7f4ece11e329\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e f5c07698-32da-4ad9-b6ca-d78da70831d9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e f558a69d-f1f1-400c-a032-216049321485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 8882a8d1-40a6-4f25-bb9a-6c7d1acba023\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 5dce91d8-2959-4bff-9a92-843f599bb3f1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e e6e1e979-50cc-4e89-8238-724b4f933c05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 55b752b3-ebd6-42f5-8fe0-6a4e82f48a58\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e b494e761-5c34-411b-b13b-799e88da7591\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e Per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 … 2000 m \/ 0 … 6562 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.967MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 50.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 69.8 mm \/ 2.748 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 62.6 mm \/ 2.465 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 12 mm \/ 0.472 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator connection:\u003c\/strong\u003e 2 x (2-wire, 4-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration options:\u003c\/strong\u003e WAGO-I\/O-\u003ci\u003eCHECK\u003c\/i\u003e|\u003cb\u003e\u003ci\u003ee!\u003c\/i\u003e\u003c\/b\u003e\u003ci\u003eCOCKPIT\u003c\/i\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion time (typ.):\u003c\/strong\u003e 5ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption (5 V system supply):\u003c\/strong\u003e 125mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData width:\u003c\/strong\u003e 2 x 16-bit data; 2 x 8-bit control\/status (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (A, C) green: Function AO 1, AO 2; LED (B, D) red: Error AO 1, AO 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500 V system\/field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad impedance (voltage output):\u003c\/strong\u003e ≥ 5 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error (reference temperature):\u003c\/strong\u003e 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error, deviation (max.) from the upper-range value:\u003c\/strong\u003e 0.05%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of analog outputs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of incoming power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of outgoing power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput error, deviation (max.) of the upper-range value:\u003c\/strong\u003e 0.05%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecovery time (typ.):\u003c\/strong\u003e 0.3ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution [bit]:\u003c\/strong\u003e 16bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (configurable):\u003c\/strong\u003e yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (voltage):\u003c\/strong\u003e 0 … 10 VDC; -10 … +10 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (field):\u003c\/strong\u003e 24 VDC (-15 … +20 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 5 VDC; via data contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature coefficient:\u003c\/strong\u003e \u0026lt; ±100 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of channels (module):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695365669001,"sku":"7500562","price":571.7,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-750-563","provider":"US Automation Controls","version":"1.0","type":"link"}