{"product_id":"wago-750-558","title":"Wago - 750-495","description":"\u003cp\u003eStandard analog input slice unit module with double isolation - for 3-phase pwr. measurement - WAGO (750 series) - 3-PHASE POM; 690VAC 1A - 7I\/O [7AI (3 x analog inputs (3-phase voltage measurement; 400Vac \/ 690Vac \/ 45...65Hz \/ 24-bits conversion) + 4 x analog inputs (differential current measurement; 1A))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750495\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Standard analog input slice unit module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e double isolation|for 3-phase pwr. measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 5Vdc (supplied by system)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (A) green -- Communication|LED (B-G) red -- Error L1\/Override in Current Measurement Path (display)\/Undervoltage in Voltage Measurement Path (display)\/Error L2\/Error L3\/Override in Voltage Measurement Path (display)|LED (H) yellow -- Interchange in Phase Sequence L1-L2-L3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e spring CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 3 x analog inputs (3-phase voltage measurement; 400Vac \/ 690Vac \/ 45...65Hz \/ 24-bits conversion)|4 x analog inputs (differential current measurement; 1A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e AC current\/voltage; +-0.5% (measuring error)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W24mm x D67.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 12mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 100mA (5Vdc; system supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 750-495\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 750495\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4050821548256\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|Insulation coordination per EN\/UL 61010-2-201 with N connection|- Insulation type -- Reinforced insulation|- Note on system voltage -- The system voltage is derived from the line-to-neutral voltage for common MAINS supply systems.|- Overvoltage category -- III|- System voltage -- ≤300V|Insulation coordination per EN\/UL 61010-2-201 without N connection|- Insulation type -- Double isolation (basic isolation and supplementary isolation by impedance\/current measurement transformer)|Safe isolation from the adjacent SELV\/PELV modules must be ensured. The product manual contains the types of isolation|to adjacent modules in section \"Isolation to Adjacent I\/O Modules per EN\/UL 61010 2-201.\" Without double or reinforced isolation|the 750-495\/000-00x Power Measurement Module must not be placed directly next to SELV\/PELV modules.|The 750-616\/040-000 Distance Module must be used under such conditions.|- Note on system voltage -- the module' N connector must not be connected to ensure safe insulation. The system voltage|corresponds to the line conductor\/neutral conductor voltage which was derived from standard power supply systems|- Overvoltage category -- III|- System voltage -- ≤600V|CE|EMC immunity to interference|- EN 61000-6-2|EMC emission of interference|- EN 61000-6-3|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03080|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-AIM750|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- BSH - Bundesamt fuer Seeschifffahrt und Hydrographie - certificate 1104|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Programmable Logic Controllers \u0026amp; components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e I-O Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Standard analog input slice unit module - double isolation - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85389099990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001596\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 15 (I\/O System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: inputs\/outputs:\u003c\/strong\u003e 12 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Inputs\/outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (conductor cross-section):\u003c\/strong\u003e Solid conductor: 20 … 14 AWG (UL); Fine-stranded conductor: 20 … 16 AWG (UL) These values refer exclusively to the mechanical connection capacity of the clamping points. When the applications\/devices are operated in locations covered by UL, only solid conductor with 20 … 14 AWG and fine-stranded conductor with 20 … 16 AWG are permitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 0ab7d5e9-43fc-483b-91d0-6c34e6674317\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e 5b4d8695-cd28-4784-a429-8d4505f65451\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61000-6-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal up, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 … 2000 m \/ 0 … 6562 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 4g per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 2.001MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 90.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 67.8 mm \/ 2.669 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 60.6 mm \/ 2.386 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24 mm \/ 0.945 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 with N connection - Insulation type:\u003c\/strong\u003e Reinforced insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 with N connection - Note on system voltage:\u003c\/strong\u003e The system voltage is derived from the line-to-neutral voltage for common MAINS supply systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 with N connection - Overvoltage category:\u003c\/strong\u003e III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 with N connection - System voltage:\u003c\/strong\u003e ≤300 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 without N connection - Insulation type:\u003c\/strong\u003e Double isolation (basic isolation and supplementary isolation by impedance\/current measurement transformer) Safe isolation from the adjacent SELV\/PELV modules must be ensured. The product manual contains the types of isolation to adjacent modules in section “Isolation to Adjacent I\/O Modules per EN\/UL 61010 2-201.” Without double or reinforced isolation, the 750-495\/000-00x Power Measurement Module must not be placed directly next to SELV\/PELV modules. Under such conditions, the 750-616 Distance Module must be used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 without N connection - Note on system voltage:\u003c\/strong\u003e To ensure safe insulation, the module's N connector must not be connected. The system voltage corresponds to the line conductor\/neutral conductor voltage, which was derived from standard power supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 without N connection - Overvoltage category:\u003c\/strong\u003e III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination per EN\/UL 61010-2-201 without N connection - System voltage:\u003c\/strong\u003e ≤ 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement category per EN\/UL 61010-2-030:\u003c\/strong\u003e CAT III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Rated impulse withstand voltage:\u003c\/strong\u003e System\/field side: 5.0 kV (EN 60870-2-1 \/ Class VW3) 6.4 kV (EN\/UL 61010-1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage:\u003c\/strong\u003e 3.51 kVAC, 50\/60 Hz, 1 min.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculated values:\u003c\/strong\u003e Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption (5 V system supply):\u003c\/strong\u003e 100mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent path input resistance (typ.):\u003c\/strong\u003e 22 mΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData width:\u003c\/strong\u003e 2 x 128-bit data; 2 x 64-bit control\/status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency range (harmonics analysis):\u003c\/strong\u003e 0 … 3300 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency range (mains frequency):\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (A) green: Communication; LED (B-G) red: Error L1, Override in Current Measurement Path (display), Undervoltage in Voltage Measurement Path (display), Error L2, Error L3, Override in Voltage Measurement Path (display); LED (H) yellow: Interchange in Phase Sequence L1-L2-L3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit frequency:\u003c\/strong\u003e 15.9kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement current (max.):\u003c\/strong\u003e 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement cycle time:\u003c\/strong\u003e Adjustable for arithmetic mean value, Min_Max_Values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error (reference temperature):\u003c\/strong\u003e 23°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error, deviation (max.) from the upper-range value:\u003c\/strong\u003e 0.5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement method:\u003c\/strong\u003e True RMS measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on common mains supply systems:\u003c\/strong\u003e U\u003csub\u003eLL\u003c\/sub\u003e up to 690°V is possible under special conditions (see manual).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of measurement inputs:\u003c\/strong\u003e 7 (3 voltage measurement inputs, 4 differential current measurement inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible common mains supply systems:\u003c\/strong\u003e Three-phase, four-wire system: max. 277\/480 VAC; Three-phase, three-wire system: max. 600 VAC (UL)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference for measurement error:\u003c\/strong\u003e AC current\/voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution [bit]:\u003c\/strong\u003e 24bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal form:\u003c\/strong\u003e Sinusoidal signals (taking the cutoff frequency into account)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Power measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 5 VDC; via data contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper-range value for the measurement accuracy:\u003c\/strong\u003e 400\/690 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage path input resistance (typ.):\u003c\/strong\u003e 1429kΩ\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47696184934537,"sku":"60400959","price":751.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/02000012000384a2000200b6_de_bd8dff77-8bf6-4b08-83bf-b6e0dc1aa447.jpg?v=1786992091","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-750-558","provider":"US Automation Controls","version":"1.0","type":"link"}