{"product_id":"wago-750-540","title":"Wago - 750-539","description":"\u003cp\u003eIntrinsically-safe DC digital output slice unit module - WAGO (750 series) - 4DO; 24Vdc; Valve; Ex i - 4I\/O [4DO (4 x digital outputs (24Vdc; high-side switching; 2-wire))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (24mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750539\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Intrinsically-safe DC digital output slice unit module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 5Vdc (supplied by system)|24Vdc fixed suppl. to field sensing devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 100Hz switching frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED (A\/B\/E\/F) green -- Status DO 1...DO 4|LED (C\/D\/G\/H) red -- Diagnostics DO 1...DO 4|\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e spring CAGE CLAMP connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs:\u003c\/strong\u003e 4 x digital outputs (24Vdc; high-side switching; 2-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H100mm x W24mm x D67.8mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 24mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate (PC) \/ Polyamide (PA) 6.6 housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e 0°C...+55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -25°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical resistance:\u003c\/strong\u003e Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 20mA (5Vdc; system supply)|10mA (field supply; no external load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 4.86W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-24-26-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85371098990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC001599\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation\/losses:\u003c\/strong\u003e 2.86W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 750-539\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 750539\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143514149\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e CE|EMC immunity to interference|- EN 61000-6-2|- marine applications|EMC emission of interference|- EN 61000-6-3|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 \/ Clause 3 - certificate MSIP-REM-W43-DOM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Ex-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- UK-Ex-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 22-2219060|- DNV - DNV GL SE - DNV-CG-0339 \/ Aug.2021 - certificate TAA0000194|- KR - Korean Register of Shipping - certificate KR HMB05880-AC001|- LR - Lloyds Register EMEA - certificate LR22180952TA|- PRS - Polski Rejestr Statkow - certificate TE\/1101\/880590\/23|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV12ATEX106032X (Ex ec[iaGa] IIC T4 Gc \/ [Ex iaDa] IIIC \/ [Ex iaMa] I)|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000211 (Ex ec[iaGa] IIC T4 Gc \/ [Ex iaDa] IIIC \/ [Ex iaMa] I)|- IECEx - TUV Nord Cert GmbH - IEC 60079 \/ IEC 60079-0 - certificate IECEx TUN12.0039X (Ex ec[iaGa] IIC T4 Gc \/ [Ex iaDa] IIIC \/ [Ex iaMa] I)|- INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV_14.1911_X|- KTL - Korea Testing Laboratory - KOSHA Article 34 \/ IEC60079-0 - certificate 21-KA4BO-0560X|- UKEx - Element Materials Technology UK - certificate EMA21UKEX0069X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Programmable Logic Controllers \u0026amp; components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e I-O Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Intrinsically-safe DC digital output slice unit module - WAGO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85371098990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-24-26-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-24-26-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001599\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001599\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectable conductor materials:\u003c\/strong\u003e Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology: inputs\/outputs:\u003c\/strong\u003e 8 x CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Inputs\/outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e e34a3d4a-a1fb-40f8-bb5b-54bf7c28fdaa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 2ce8ca47-89a4-4c43-9427-dd8fe99d3e7b\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 75528983-07fe-4087-af2d-af7edf979c73\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e f9fb62b0-c110-4b20-b537-5f7510b2a650\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 64b48830-f285-4cef-aac8-318ab049c8ef\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e d21d7caf-d593-4078-a77f-144b060c5b80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 8b7b3506-826e-4320-9f88-d4aca5af520d\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 8ec2c402-dd38-40d4-a575-630c5dcb958a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 441ec9b2-f306-4c04-afe9-d73926e312af\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 74e79e14-0ac4-47f2-8486-55872426dabd\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e 74678b8e-c44c-499b-a41f-66be291f6a26\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 7afc2831-b145-414f-83b7-93c174189b9a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 470ef858-fac1-4205-8178-bee373f05ff7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e 3528ae04-7447-476d-a23d-783b22d2f64a\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e 0 … +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -25 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e per EN 61000-6-3, marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e per EN 61000-6-2, marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposure to pollutants:\u003c\/strong\u003e per IEC 60068-2-42 and IEC 60068-2-43\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting position:\u003c\/strong\u003e Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 … 2000 m \/ 0 … 6562 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible H\u003csub\u003e2\u003c\/sub\u003eS contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible SO\u003csub\u003e2\u003c\/sub\u003e contaminant concentration at a relative humidity \u003clt\u003e\u003c\/lt\u003e 75 %:\u003c\/strong\u003e 25ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 per IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity (without condensation):\u003c\/strong\u003e 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15g per IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 4g per IEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExplosion protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx standard:\u003c\/strong\u003e EN IEC 60079-0, -7, -11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentification:\u003c\/strong\u003e ATEX\u003cbr\u003eII 3 (1) G Ex ec [ia Ga] IIC T4 Gc\u003cbr\u003eII (1) D [Ex ia Da] IIIC\u003cbr\u003eI (M1) [Ex ia Ma] I|IECEx\/ INMETRO\u003cbr\u003eEx ec [ia Ga] IIC T4 Gc\u003cbr\u003e[Ex ia Da] IIIC\u003cbr\u003e[Ex ia Ma] I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances (note):\u003c\/strong\u003e Reactances without accounting for the concurrence of capacitance (C\u003csub\u003eo\u003c\/sub\u003e) and inductance (L\u003csub\u003eo\u003c\/sub\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances Ex ia I:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 21 mH; C\u003csub\u003eo\u003c\/sub\u003e = 540 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances Ex ia IIA:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 14 mH; C\u003csub\u003eo\u003c\/sub\u003e = 2.28 μF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances Ex ia IIB:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 8.1 mH; C\u003csub\u003eo\u003c\/sub\u003e = 683 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactances Ex ia IIC:\u003c\/strong\u003e L\u003csub\u003eo\u003c\/sub\u003e = 13 µH; C\u003csub\u003eo\u003c\/sub\u003e = 88 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety-relevant data (circuit):\u003c\/strong\u003e U\u003csub\u003eo\u003c\/sub\u003e = 27.3 V; I\u003csub\u003eo\u003c\/sub\u003e = 117.5 mA; P\u003csub\u003eo\u003c\/sub\u003e = 800.1 mW; linear characteristic curve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 2.035MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Polycarbonate; polyamide 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 88.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cp\u003eThe digital output module must only be operated via 24 VDC Ex i!\u003c\/p\u003e\n\u003cp\u003eGeneral information (e.g., installation regulations) on explosion protection is available in the WAGO I\/O System 750 manuals!\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 67.8 mm \/ 2.669 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 60.6 mm \/ 2.386 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 100 mm \/ 3.937 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24 mm \/ 0.945 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator connection:\u003c\/strong\u003e 4 x (2-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent carrying capacity (power jumper contacts):\u003c\/strong\u003e 1A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption (5 V system supply):\u003c\/strong\u003e 20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption, field supply (module with no external load):\u003c\/strong\u003e 10mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED (A, B, E, F) green: Status DO 1 … DO 4; LED (C, D, G, H) red: Diagnostics DO 1 … DO 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput data width (internal) max.:\u003c\/strong\u003e 4bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal resistance R\u003csub\u003ei\u003c\/sub\u003e:\u003c\/strong\u003e 290Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsically safe Ex i:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e UM = 375 V system\/supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eItem description:\u003c\/strong\u003e 4-Channel Digital Output; 24 VDC; Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad type:\u003c\/strong\u003e Resistive, inductive, lamp load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of digital outputs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of incoming power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of outgoing power jumper contacts:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput characteristic:\u003c\/strong\u003e high-side switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput current per channel:\u003c\/strong\u003e 0.047A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput data width (internal) max.:\u003c\/strong\u003e 4bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption P\u003csub\u003emax.\u003c\/sub\u003e:\u003c\/strong\u003e 4.86 W (at 47 mA output current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower loss P\u003csub\u003el\u003c\/sub\u003e:\u003c\/strong\u003e 2.86 W (at 47 mA output current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type (voltage):\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (field):\u003c\/strong\u003e 24 VDC; (Ex i power supply: U\u003csub\u003eo\u003c\/sub\u003e = max. 26.8 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (system):\u003c\/strong\u003e 5 VDC; via data contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency (max.):\u003c\/strong\u003e 100 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of channels (module):\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695441723529,"sku":"60313795","price":623.7,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-750-540","provider":"US Automation Controls","version":"1.0","type":"link"}