Standard analog input slice unit module - WAGO (750 series) - 8AI; TC; Adjust - 8I/O [8AI (8 x analog inputs (Thermocouple type K; J; B; E; N; R; S; T; C; 0.1°C resolution; 2-wire))] - supply voltage 5Vdc (supplied by system) - with Push-in spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750498

Specifications

  • Primary brand: WAGO
  • Functions: Standard analog input slice unit module|Configuration options|- WAGO-I/O-CHECK|- CODESYS Library|- e!COCKPIT
  • Supply voltage (DC): 5Vdc (supplied by system)|18-31.2Vdc adjustable suppl. to field sensing devices
  • Connection type: Push-in spring CAGE CLAMP connections
  • Mounting mode: DIN-35 rail
  • Analog inputs: 8 x analog inputs (Thermocouple type K; J; B; E; N; R; S; T; C; 0.1°C resolution; 2-wire)
  • Measurement accuracy: +-0.05% (temperature error)
  • Dimensions: H100mm x W12mm x D69mm
  • Net Width (mm): 12mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g
  • Current consumption: 100mA (5Vdc; system supply)
  • Customs Tariff Number: 85389099990
  • GTIN code: 4055143944380
  • ETIM code: EC001596
  • Order code / Manufacturer SKU: 750-498
  • Manufacturer product status: Commercialized
  • Equivalent to: 750498
  • EAN code: 4055143944380
  • Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-2|- EN 61131-2|EMC emission of interference|- EN 61000-6-3|- EN 61131-2|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- BSH - Bundesamt fuer Seeschifffahrt und Hydrographie - certificate 1104|- BV - Bureau Veritas S.A. - Rules for class. of Steel Ships - certificate 66711/A0|- DNV GL - Det Norske Veritas Germanischer Lloyd - DNVGL-CG-339 / Nov.2016 - certificate TAA00002K2|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV 12.1297 X|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Standard analog input slice unit module - WAGO

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85389099990
  • ECCN: NO US CLASSIFICATION
  • ETIM 8.0: EC001596
  • ETIM 9.0: EC001596
  • GTIN: 4055143944380
  • Packaging type: box
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: inputs/outputs: 16 x Push-in CAGE CLAMP®
  • Connection type 1: Inputs/outputs
  • Fine-stranded conductor: 0.25 … 1.5 mm² / 22 … 16 AWG
  • Solid conductor: 0.08 … 1.5 mm² / 28 … 16 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Environmental Product Compliance

  • CAS-No.: 12060-00-3|12626-81-2|1303-86-2|1317-36-8|7439-92-1
  • REACH Candidate List Substance: Diboron trioxide|Lead|Lead monoxide|Lead titanium oxide (PbTiO3)|Lead titanium zirconium oxide (Pb(Ti,Zr)O3)
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): f6735f8e-5ed0-4b19-b01a-c84836383432
  • SCIP notification number (Belgium): 40dde180-eeb7-44e2-a3c2-6d459beea0f6
  • SCIP notification number (Bulgaria): 17b4a04f-6a56-4906-98ef-68f5187c67bb
  • SCIP notification number (Czech Republic): c655c53f-bf90-48b4-accb-11d8423ca2cb
  • SCIP notification number (Denmark): 77b4f325-303c-4d0f-b4a6-bf3b6f39cf0e
  • SCIP notification number (Finland): 043412a0-436a-419a-b605-0253e6596fac
  • SCIP notification number (France): 52e4b31a-37d0-4f16-b015-6728e0784851
  • SCIP notification number (Germany): 2772e26d-1005-4081-8e88-75048872c85b
  • SCIP notification number (Hungary): 4f91372f-d671-4ecd-bb80-5ac1f6dde9a4
  • SCIP notification number (Italy): a4376f3e-2ac5-42ee-ac28-37a1ee973a82
  • SCIP notification number (Netherlands): 6e040007-e411-4954-bb29-a5db777b8dbf
  • SCIP notification number (Poland): 143cbffc-74d9-45bc-9bb9-e0d65e0b7616
  • SCIP notification number (Romania): 423c9bbe-539b-4a45-857a-783369ee023f
  • SCIP notification number (Sweden): 7789035f-c5ed-4027-88ee-9404a04d32ec

Environmental requirements

  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -40 … +85 °C
  • EMC emission of interference: per EN 61000-6-3, EN 61131-2
  • EMC immunity to interference: per EN 61000-6-2, EN 61131-2
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
  • Operating altitude: 0 … 2000 m / 0 … 6562 ft
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (without condensation): 95%
  • Shock resistance: 15g per IEC 60068-2-27
  • Vibration resistance: 4g per IEC 60068-2-6

Material data

  • Conformity marking: CE
  • Fire load: 0.837MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 48.9g

Mechanical data

  • Mounting type: DIN-35 rail

Physical data

  • Depth: 69 mm / 2.717 inches
  • Depth from upper-edge of DIN-rail: 61.8 mm / 2.433 inches
  • Height: 100 mm / 3.937 inches
  • Width: 12 mm / 0.472 inches

Technical data

  • Cold junction compensation: Module-internal based on a cold junction temperature measurement
  • Configuration options: WAGO-I/O-CHECK|CODESYS Library|e!COCKPIT
  • Conversion time: ≤100 ms (per channel), activated notch filter; ≤50 ms (per channel), deactivated notch filter
  • Current consumption (5 V system supply): 100mA
  • Data width: 8 x 16-bit data; 8 x 8-bit control/status (optional)
  • Indicators: LED (1-8) green: Status TC 1 … TC 8; LED (9-16) red: Error TC 1 … TC 8
  • Isolation: 500 V system/field
  • Measurement error (25 °C): with cold junction compensation: ≤ ±1 K (type E, N, K, T, J) at ≥-50 °C; ≤ ±2 K (type S, R, C) at ≥100 °C; ≤ ±3 K (type B) at ≥350 °C;(Please find additional measurement error information in the manual.)
  • Number of analog inputs: 8
  • Number of incoming power jumper contacts: 2
  • Number of outgoing power jumper contacts: 2
  • Resolution (over entire range): 0.1 °C
  • Sensor connection: 8 x (2-wire)
  • Sensor types: Type K, J, B, E, N, R, S, T, C; Voltage measurement: ±30 mV; ±60 mV; ±120 mV; ±240 mV
  • Signal type: Thermocouple|Low voltages
  • Signal type (configurable): Yes
  • Supply voltage (field): 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)
  • Supply voltage (system): 5 VDC; via data contacts
  • Temperature coefficient: Type K: ±0.05 K/K of the upper-range value; Voltage measurements: ±50 ppm/K of the upper-range value
  • Temperature error (max.) of the upper-range value: 0.05%/K
  • Total number of channels (module): 8