Wago - 750-421
$169.40
Sale price
$169.40
Regular price
Standard DC digital input slice unit module with diagnostics + automatic acknowledgement - WAGO (750 series) - 2DI; 24Vdc; 3ms; Diagn - 2I/O [2DI (2 x digital inputs (24Vdc transistor; high-side switching; 2-wire / 3-wire; 3ms filter))] - supply voltage 5Vdc (supplied by system) - with spring CAGE CLAMP connections - DIN-35 rail mounting (12mm width) - IP20 - rated for 0°C...+55°C ambient - equivalent to 750421
Specifications
- Primary brand: WAGO
- Functions: Standard DC digital input slice unit module
- Design: diagnostics|automatic acknowledgement
- Supply voltage (DC): 5Vdc (supplied by system)|18-31.2Vdc adjustable suppl. to field sensing devices
- Display: LED (A/C) green -- Status DI 1 / DI 2|LED (B/D) red -- Error DI 1 / DI 2
- Connection type: spring CAGE CLAMP connections
- Protection functions: short-circuit protection
- Mounting mode: DIN-35 rail
- Digital inputs: 2 x digital inputs (24Vdc transistor; high-side switching; 2-wire / 3-wire; 3ms filter)|Digital inputs voltage ranges -3...+5Vdc (OFF) / 15-30Vdc (ON)
- Dimensions: H100mm x W12mm x D69.8mm
- Net Width (mm): 12mm
- Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
- Ambient air temperature for operation: 0°C...+55°C
- Ambient air temperature for storage: -40°C...+85°C
- Humidity: 95% relative humidity (RH; non-condensing)
- Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 4g|Shock resistance according to EN 60068-2-27 --15g
- Current consumption: 12mA (5Vdc; system supply)
- eClass code: 27-24-26-04
- Customs Tariff Number: 85389099990
- ETIM code: EC001599
- Order code / Manufacturer SKU: 750-421
- Manufacturer product status: Commercialized
- Equivalent to: 750421
- EAN code: 4045454495008
- Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-2|- marine applications|EMC emission of interference|- EN 61000-6-4|- marine applications|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DIM750|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 508 - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - certificate 22-2219060|- BSH - Bundesamt fuer Seeschifffahrt und Hydrographie - certificate 1104|- BV - Bureau Veritas S.A. - certificate 13453/E0 BV|- DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194|- KR - Korean Register of Shipping - certificate KR HMB05880-AC001|- LR - Lloyds Register EMEA - certificate LR22180952TA|- PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23|- RINA - RINA Germany GmbH - certificate ELE343521XG001|Approvals for hazardous areas|- ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)|- CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)|- IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)|- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X|- KTL - Korea Testing Laboratory - KOSHA Article 34 / IEC60079-0 - certificate 21-KA4BO-0553X|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
- Location of origin: Germany
- Degree of pollution: 2
- Level 1 category: Automation components
- Level 2 category: Programmable Logic Controllers & components
- Level 3 category: I-O Units
- Product title: Standard DC digital input slice unit module - diagnostics - WAGO
Commercial data
- Country of origin: DE
- Customs tariff number: 85389099990
- ECCN: NO US CLASSIFICATION
- eCl@ss 10.0: 27-24-26-04
- eCl@ss 9.0: 27-24-26-04
- ETIM 8.0: EC001599
- ETIM 9.0: EC001599
- Packaging type: Box
- Product Group: 15 (I/O System)
- PU (SPU): 1 pcs
Connection data
- Connectable conductor materials: Copper
- Connection technology: inputs/outputs: 8 x CAGE CLAMP® (inputs)
- Connection type 1: Input
- Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Strip length: 8 … 9 mm / 0.31 … 0.35 inches
Environmental Product Compliance
- CAS-No.: 1303-86-2|1317-36-8|7439-92-1|79-94-7
- REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide
- RoHS Compliance Status: Compliant,With Exemption
- RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
- SCIP notification number (Austria): 803ed15f-47c7-47af-93c7-03f4217ca831
- SCIP notification number (Belgium): a4eadee4-501f-404d-907a-d2abde33bebc
- SCIP notification number (Bulgaria): eb4795f9-30a6-4773-a667-b06bf93c3a72
- SCIP notification number (Czech Republic): 549d6e19-fcd3-4abc-bcae-42c616a2f9cf
- SCIP notification number (Denmark): 1b35d4c1-68b8-4707-9d46-8ca3a5acd5d8
- SCIP notification number (Finland): e0c0e1b3-91a5-469f-8da1-4d4d99097b96
- SCIP notification number (France): 51bb9dff-ee15-4e7d-9af9-4150d1c8c11a
- SCIP notification number (Germany): fc9f1adf-96cf-445e-b9c7-6e803f976708
- SCIP notification number (Hungary): d2f9a2d6-007f-41d5-904a-f281d8970651
- SCIP notification number (Italy): 12ce542d-acf7-4617-a9e0-ced61fc4108b
- SCIP notification number (Netherlands): 57a24adf-2146-4697-8320-6060779bb171
- SCIP notification number (Poland): fb1f3cf0-883f-4331-9602-346ac3571954
- SCIP notification number (Romania): 87107905-be31-4c23-a2f0-4e2a534580d6
- SCIP notification number (Sweden): 63b3124a-dd15-4c17-b337-c5c391958f50
Environmental requirements
- Ambient temperature (operation): 0 … +55 °C
- Ambient temperature (storage): -40 … +85 °C
- EMC emission of interference: per EN 61000-6-4, marine applications
- EMC immunity to interference: per EN 61000-6-2, marine applications
- Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
- Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
- Operating altitude: 0 … 2000 m / 0 … 6562 ft
-
Permissible H2S contaminant concentration at a relative humidity
75 %: 10ppm -
Permissible SO2 contaminant concentration at a relative humidity
75 %: 25ppm - Pollution degree: 2 per IEC 61131-2
- Protection type: IP20
- Relative humidity (without condensation): 95%
- Shock resistance: 15g per IEC 60068-2-27
- Vibration resistance: 4g per IEC 60068-2-6
Material data
- Color: light gray
- Conformity marking: CE
- Fire load: 1.316MJ
- Housing material: Polycarbonate; polyamide 6.6
- Weight: 49.8g
Mechanical data
- Mounting type: DIN-35 rail
- Pluggable connector: fixed
Physical data
- Depth: 69.8 mm / 2.748 inches
- Depth from upper-edge of DIN-rail: 62.6 mm / 2.465 inches
- Height: 100 mm / 3.937 inches
- Width: 12 mm / 0.472 inches
Technical data
- Current carrying capacity (power jumper contacts): 10A
- Current consumption (5 V system supply): 12mA
- Diagnostics: Short circuit, automatic acknowledgment after error rectified
- Indicators: LED (A, C) green: Status DI 1, DI 2; LED (B, D) red: Error DI 1, DI 2
- Input characteristic: high-side switching
- Input current per channel for signal (1) typ.: 3.7mA
- Input data width (internal) max.: 4bits
- Input filter (digital): 3ms
- Isolation: 500 V system/field
- Number of digital inputs: 2
- Number of incoming power jumper contacts: 2
- Number of outgoing power jumper contacts: 2
- Output current per channel: 0.5A
- Sensor connection: 2 x (2-wire, 3-wire)
- Sensor supply: 24 VDC
- Short-circuit current: 1.5 A, pulsating due to thermal overload protection
- Signal type: Digital
- Signal type (voltage): 24 VDC
- Supply voltage (field): 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)
- Supply voltage (system): 5 VDC; via data contacts
- Total number of channels (module): 2
- Voltage range for signal (0): −3 … +5 VDC
- Voltage range for signal (1): 15 … 30 VDC