Wago - 750-365/040-010

$1,132.00
Sale price  $1,132.00 Regular price 

Wago - 750-365/040-010

$1,132.00
Sale price  $1,132.00 Regular price 

Fieldbus coupler / head (remote I/O (RIO) controller unit) with extended temperature range - Gen.4 - WAGO (750 XTR series) - FC EtherNet/IP M12; G4; XTR - 64 x connections per node connection capability - with Ethernet/IP communication capability - supply voltage 24Vdc via wiring (system) + 24Vdc via pwr. jumper (Field) - with 5-pin M12 connector (fieldbus) - DIN-35 rail mounting (112mm width) - IP20 - rated for -40°C...+70°C ambient - equivalent to 750365040010

Specifications

  • Primary brand: WAGO
  • Functions: Fieldbus coupler / head (remote I/O (RIO) controller unit)|HTTP|BootP|DHCP|DNS|FTP|SNMP|Configuration options|- WAGO-I/O-CHECK|- Web-Based Management|- CODESYS Library
  • Design: extended temperature range|Gen.4
  • Supply voltage (DC): 24Vdc via wiring (system) + 24Vdc via pwr. jumper (Field)|18-31.2Vdc (Ambient temperatures under laboratory conditions)|18-28.8Vdc (-40...+55°C)|18-26.4Vdc (-55...+70°C)
  • Connection capacity: 64 x connections per node
  • Connection type: 5-pin M12 connector (fieldbus)|spring CAGE CLAMP (pwr. suppl. connections)|4-pin male connector (device configuration)
  • Mounting mode: DIN-35 rail
  • Speed: 10Mbit/s / 100Mbit/s
  • Dimensions: H100mm x W112mm x D71.9mm
  • Net Width (mm): 112mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance: Vibration resistance according to EN 60068-2-6 -- 5g|Shock resistance according to EN 60068-2-27 --15g (11ms / half-sine / 1000 shocks)|Shock resistance according to EN 60068-2-27 --25g (6ms / 1000 shocks)
  • Current consumption: 500mA (24Vdc; at nominal load)|350mA (5Vdc; system supply)|1700mA (system supply)
  • ETIM code: EC001603
  • Customs Tariff Number: 85371091990
  • Order code / Manufacturer SKU: 750-365/040-010
  • Manufacturer product status: Commercialized
  • Equivalent to: 750365040010
  • EAN code: 4055143923118
  • Compliant with standard(s): CE|EMC immunity to interference|- EN 61000-6-1|- EN 61000-6-2|- EN 61131-2|- marine applications|- EN 50121-3-2|- EN 50121-4|- EN 50121-5|- EN 60255-26|- EN 60870-2-1|- EN 61850-3|- IEC 61000-6-5|- IEEE 1613|- VDEW (1994)|EMC emission of interference|- EN 61000-6-3|- EN 61000-6-4|- EN 61131-2|- EN 60255-26|- marine applications|- EN 60870-2-1|- EN 61850-3|- EN 50121-3-2|- EN 50121-4|- EN 50121-5|General approvals|- EAC - GZO Almaty Standart - TP TC 020/2011 - certificate EAC CoC 03083|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - certificate E175199|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- PRS - Polski Rejestr Statkow - certificate TE/1099/880590/23|Approvals for hazardous areas|- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000214 (Ex ec IIC T4 Gc)|- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX005X_ec|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Location of origin: Germany
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Fieldbus coupler / head (remote I/O (RIO) controller unit) - WAGO (XTR series)

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85371091990
  • ECCN: NO US CLASSIFICATION
  • ETIM 8.0: EC001603
  • ETIM 9.0: EC001603
  • Packaging type: Box
  • PU (SPU): 1 pcs

Connection data

  • Connectable conductor materials: Copper
  • Connection technology: communication/fieldbus: EtherNet/IPTM: 2 x M12 socket; 4-pole; D-coded
  • Connection technology: device configuration: 1 x Male connector; 4-pole
  • Connection technology: field supply: 6 x CAGE CLAMP®
  • Connection technology: system supply: 2 x CAGE CLAMP®
  • Connection type 1: System/field supply
  • Fine-stranded conductor: 0.25 … 2.5 mm² / 24 … 14 AWG
  • Solid conductor: 0.25 … 2.5 mm² / 24 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inches

Environmental Product Compliance

  • CAS-No.: 1303-86-2|1317-36-8|7439-92-1|79-94-7
  • REACH Candidate List Substance: 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Perfluorobutane sulfonic acid (PFBS) and its salts
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)|7(a)|7(c)-I|7(c)-II
  • SCIP notification number (Austria): 030ea7c9-c9ce-4149-ac4b-56c79fba5148
  • SCIP notification number (Belgium): 25117b68-7c95-4695-86b3-ef38edb64ee5
  • SCIP notification number (Bulgaria): 11786d85-6149-4ce8-8417-e4e3caa7baed
  • SCIP notification number (Czech Republic): beafd98b-497a-444a-a387-908ccfffad95
  • SCIP notification number (Denmark): 4f0db2a2-96bf-40f0-877a-73b58b5df4bb
  • SCIP notification number (Finland): 9e9516e7-03f7-4bf8-8db6-36c7cc1db769
  • SCIP notification number (France): 7bde4160-59f9-46d5-a1da-cb7e3cc1f0e1
  • SCIP notification number (Germany): c67e4e7a-b58c-429e-b936-85622ec518fd
  • SCIP notification number (Hungary): f026b566-be53-49ad-bc14-20324186f2ed
  • SCIP notification number (Italy): 5edc2355-d4c2-41a9-8006-1241c6db2814
  • SCIP notification number (Netherlands): caaea08b-1f2d-4ec7-8c2e-7576c94bed32
  • SCIP notification number (Poland): 5c5cdef9-3b06-4815-b1d7-ff4243f2f6d5
  • SCIP notification number (Romania): fc9dc4c0-2fae-4df1-8a4d-5d27f61b4da9
  • SCIP notification number (Sweden): ae621d2d-3a30-4000-ba81-fd412e79b00c

Environmental requirements

  • Ambient temperature (operation): -40 … +70 °C
  • Ambient temperature (storage): -40 … +85 °C
  • EMC emission of interference: per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
  • EMC immunity to interference: per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;
    EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Mounting position: Horizontal left, horizontal up, vertical top and vertical bottom
  • Operating altitude: without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pollution degree: 2 per IEC 61131-2
  • Protection type: IP20
  • Relative humidity (with condensation): Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
  • Relative humidity (without condensation): 95%
  • Shock resistance: per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
  • Vibration resistance: per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373

Material data

  • Conformity marking: CE
  • Fire load: 3.284MJ
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 213g

Mechanical data

  • Mounting type: DIN-35 rail

Physical data

  • Depth: 71.9 mm / 2.831 inches
  • Depth from upper-edge of DIN-rail: 64.7 mm / 2.547 inches
  • Height: 100 mm / 3.937 inches
  • Width: 112 mm / 4.409 inches

Technical data

  • Communications: EtherNet/IPTM
  • Configuration options: WAGO-I/O-CHECK|Web-Based Management|CODESYS Library
  • Current carrying capacity (power jumper contacts): 10A
  • Current consumption (5 V system supply): 350mA
  • Derating: Derating (supply voltage):
    Ambient temperatures under laboratory conditions: (‒25 … +30°%);
    for ‒40 … +55°°C: 24°V (‒25 … +20°%);
    for +55 … +70°°C: 24°V (‒25 … +10°%);
    Lower limit in all temperature ranges: ‒27.5°% (including 15°% residual ripple)
  • ETHERNET protocols: HTTP(S)|BootP|DHCP|DNS|FTP(S)|SNMP
  • Indicators: LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O) red/green/orange: Status of local data bus
  • Input and output process image (fieldbus) max.: 1020 words/1020 words
  • Input current (typ.) at nominal load (24 V): 500mA
  • Number of modules per node (max.): 64
  • Number of modules without a bus extension (max.): 64
  • Power supply efficiency (typ.) at nominal load (24 V): 90%
  • Rated impulse withstand voltage: 1 kV
  • Supply voltage (field): 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
  • Supply voltage (system): 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
  • Total current (system supply): 1,700mA
  • Transmission medium (communication/fieldbus): Twisted pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; 100 m maximum cable length
  • Transmission performance: Class D per EN 50173
  • Transmission rate: 10/100 Mbit/s

You may also like