{"product_id":"wago-722-837","title":"Wago - 722-837","description":"\u003cp\u003eWAGO component - equivalent to 722837\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4044918581066\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 722-837\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 722837\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4044918581066\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e THT female header; angled; Pin spacing 7.5mm; 7-pole; 100% protected against mismating; 0.6 x 1mm solder pin; light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Safety Information -- The MCS - MULTI CONNECTION SYSTEM includes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended; these connectors must not be connected\/disconnected when live or under load.When used as intended; these connectors must not be connected\/disconnected when live or under load. The circuit design should ensure header pins; which can be touched; are not live when unmated.|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 500V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated voltage (III\/2) -- 630V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III\/2) -- 6kV|Electrical data - Ratings per IEC\/EN - Nominal voltage (II\/2) -- 1000V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (II\/2) -- 6kV|Electrical data - Ratings per IEC\/EN - Rated current -- 12A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 2) Overvoltage category III \/ Pollution degree 2|Electrical data - Ratings per UL - Approvals per -- UL 1059|Electrical data - Ratings per UL - Rated voltage UL (Use Group B) -- 300V|Electrical data - Ratings per UL - Rated current UL (Use Group B) -- 15A|Electrical data - Ratings per UL - Rated voltage UL (Use Group D) -- 300V|Electrical data - Ratings per UL - Rated current UL (Use Group D) -- 10A|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 15A|Electrical data - Ratings per CSA - Approvals per -- CSA|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group B) -- 300V|Electrical data - Ratings per CSA - Rated current CSA (Use Group B) -- 15A|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group D) -- 300V|Electrical data - Ratings per CSA - Rated current CSA (Use Group D) -- 10A|Connection data - Total number of potentials -- 7|Connection data - Number of connection types -- 1|Connection data - Number of levels -- 1|Connection data - Connection 1 - Pole number -- 7|Physical data - Pin spacing -- 7.5mm \/ 0.295\"|Physical data - Width -- 51.5mm \/ 2.028\"|Physical data - Height -- 16.6mm \/ 0.654\"|Physical data - Height from the surface -- 11.6mm \/ 0.457\"|Physical data - Depth -- 18.25mm \/ 0.719\"|Physical data - Solder pin length -- 5mm|Physical data - Solder pin dimensions -- 0.6 x 1mm|Physical data - Drilled hole diameter with tolerance -- 1.3 \u003csup\u003e(+0.1)\u003c\/sup\u003emm|Mechanical data - Variable coding -- Yes|Mechanical data - Anti-rotation protection -- Yes|Plug-in connection - Contact type (pluggable connector) -- Female connector\/socket|Plug-in connection - Connector (connection type) -- for PCB|Plug-in connection - Mismating protection -- Yes|Plug-in connection - Plugging without loss of pin spacing -- No|Plug-in connection - Mating direction to the PCB -- 0°|Plug-in connection - Locking of plug-in connection -- none|PCB contact - PCB contact -- THT|PCB contact - Solder pin arrangement -- over the entire female connector (in-line)|PCB contact - Number of solder pins per potential -- 1|Material data - Color -- light gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Contact material -- Copper alloy|Material data - Contact plating -- Tin|Material data - Fire load -- 0.15MJ|Material data - Weight -- 7.7g|Environmental requirements - Limit temperature range -- -60...+100°C|Environmental requirements - Processing temperature -- -35...+60°C|Environmental requirements - Environmental Testing (Environmental Conditions) - Test specification \/ Railway applications - \/ Rolling stock - \/ Electronic equipment -- DIN EN 50155 (VDE 0115-200)2022-06|Environmental requirements - Environmental Testing (Environmental Conditions) - Test procedure \/ Railway applications - \/ Rolling stock equipment - \/ Shock and vibration tests -- DIN EN 61373 (VDE 0115-0106)2011-04|Environmental requirements - Environmental Testing (Environmental Conditions) - Spectrum\/Installation location -- Service life test; Category 1; Class A\/B|Environmental requirements - Environmental Testing (Environmental Conditions) - Function test with noise-like vibration -- Test passed according to Section 8 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Frequency -- f\u003csub\u003e1 \u003c\/sub\u003e= 5Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150Hz|Environmental requirements - Environmental Testing (Environmental Conditions) - Acceleration -- 0.101g (highest test level used for all axes) \/ 0.572g (highest test level used for all axes) \/ 5g (highest test level used for all axes)|Environmental requirements - Environmental Testing (Environmental Conditions) - Test duration per axis -- 10 min. \/ 5 h|Environmental requirements - Environmental Testing (Environmental Conditions) - Test directions -- X; Y and Z axes|Environmental requirements - Environmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration -- Test passed according to Section 9 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock test -- Test passed according to Section 10 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock form -- Half sine|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock duration -- 30ms|Environmental requirements - Environmental Testing (Environmental Conditions) - Number of shocks per axis -- 3 pos. und 3 neg.|Environmental requirements - Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment -- Passed|Commercial data - Product Group -- 3 (Multi Conn. System)|Commercial data - eClass 10.0 -- 27-44-04-02|Commercial data - eClass 9.0 -- 27-44-04-02|Commercial data - ETIM 9.0 -- EC002637|Commercial data - ETIM 8.0 -- EC002637|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 50 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- DE|Commercial data - GTIN -- 4044918581066|Commercial data - Customs tariff number -- 85366990990|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85366990990\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-04-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-04-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002637\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002637\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4044918581066\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 3 (Multi Conn. System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 50 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of connection types:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Approvals per:\u003c\/strong\u003e CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group B):\u003c\/strong\u003e 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group D):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group B):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group D):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 2) ≙ Overvoltage category III \/ Pollution degree 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (II\/2):\u003c\/strong\u003e 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 12A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (II\/2):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III\/2):\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated voltage (III\/2):\u003c\/strong\u003e 630V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Approvals per:\u003c\/strong\u003e UL 1059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group B):\u003c\/strong\u003e 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group D):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group B):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group D):\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Acceleration:\u003c\/strong\u003e 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Frequency:\u003c\/strong\u003e f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz|f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Function test with noise-like vibration:\u003c\/strong\u003e Test passed according to Section 8 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Number of shocks per axis:\u003c\/strong\u003e 3 pos. und 3 neg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock duration:\u003c\/strong\u003e 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock form:\u003c\/strong\u003e Half sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock test:\u003c\/strong\u003e Test passed according to Section 10 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration:\u003c\/strong\u003e Test passed according to Section 9 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Spectrum\/Installation location:\u003c\/strong\u003e Service life test, Category 1, Class A\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test directions:\u003c\/strong\u003e X, Y and Z axes|X, Y and Z axes|X, Y and Z axes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test duration per axis:\u003c\/strong\u003e 10 min.|5 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test procedure \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock equipment – \u003cbr\u003eShock and vibration tests:\u003c\/strong\u003e DIN EN 61373 (VDE 0115-0106):2011-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test specification \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock – \u003cbr\u003eElectronic equipment:\u003c\/strong\u003e DIN EN 50155 (VDE 0115-200):2022-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit temperature range:\u003c\/strong\u003e -60 … +100 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -35 … +60 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e light gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.15MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 7.7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-rotation protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable coding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e The \u003ci\u003eMCS – MULTI CONNECTION SYSTEM\u003c\/i\u003e includes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected\/disconnected when live or under load.When used as intended, these connectors must not be connected\/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole numbers|3.8 mm pin projection for male headers with straight solder pins|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePCB contact\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of solder pins per potential:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB contact:\u003c\/strong\u003e THT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin arrangement:\u003c\/strong\u003e over the entire female connector (in-line)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 18.25 mm \/ 0.719 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrilled hole diameter with tolerance:\u003c\/strong\u003e 1.3 \u003csup\u003e(+0.1)\u003c\/sup\u003e mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16.6 mm \/ 0.654 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight from the surface:\u003c\/strong\u003e 11.6 mm \/ 0.457 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 7.5 mm \/ 0.295 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin dimensions:\u003c\/strong\u003e 0.6 x 1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin length:\u003c\/strong\u003e 5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 51.5 mm \/ 2.028 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlug-in connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector (connection type):\u003c\/strong\u003e for PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type (pluggable connector):\u003c\/strong\u003e Female connector\/socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking of plug-in connection:\u003c\/strong\u003e none\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating direction to the PCB:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMismating protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlugging without loss of pin spacing:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47539928039561,"sku":"722-837","price":6.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/0200000700012e31000500b6_de_d1b7b173-53df-4dd2-a3b8-59cacbaaf4c3.jpg?v=1786983754","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-722-837","provider":"US Automation Controls","version":"1.0","type":"link"}