{"product_id":"wago-2857-536","title":"Wago - 2857-535","description":"\u003cp\u003eTemperature signal transducer \/ conditioner with analog output + software configuration - WAGO (2857 JUMPFLEX series) - with 1 x analog input (RTD Pt10 \/ Pt2000 \/ Thermocouples types J; K; E; R; N; S; T; B; C \/ Resistor; 0-10kΩ \/ Potentiometer; Resistor; 0-10kΩ; 2-wire \/ 3-wire \/ 4-wire) + 1 x analog output (-24...+24mA \/ -12...+12Vdc) - supply voltage 9.6-31.2Vdc (24Vdc nom.) - with Push-in CAGE CLAMP spring connections - DIN-35 rail mounting (22.5mm width) - IP20 - rated for -40°C...+70°C ambient - equivalent to 2857535\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Temperature signal transducer \/ conditioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e analog output|software configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (DC):\u003c\/strong\u003e 9.6-31.2Vdc (24Vdc nom.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs:\u003c\/strong\u003e 1 x digital output (SPDT (Single Pole Double Throw) rly. contact type; 250Vac; 6A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e 1 x analog input (RTD Pt10 \/ Pt2000 \/ Thermocouples types J; K; E; R; N; S; T; B; C \/ Resistor; 0-10kΩ \/ Potentiometer; Resistor; 0-10kΩ; 2-wire \/ 3-wire \/ 4-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog outputs:\u003c\/strong\u003e 1 x analog output (-24...+24mA \/ -12...+12Vdc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e ≤ 0.1% (transmission error)|≤ 0.01%\/K (temperature coefficient)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H110mm x W22.5mm x D107mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 22.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -40°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 70mA (24Vdc; at nominal load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143655507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC002919\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass code:\u003c\/strong\u003e 27-21-01-29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2857-535\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 2857535\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143655507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- II|CE|EN 61010-1|EN 61373|EMC immunity to interference|- EN 61000-6-2|- EN 61326-2-3|EMC emission of interference|- EN 61000-6-3|- EN 61326-2-3|General approvals|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03083|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03084|- UL - Underwriters Laboratories Inc. (ORDINARY LOCATIONS) - UL 61010-2-201 - certificate E175199|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Metering devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 3 category:\u003c\/strong\u003e Measurement sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 4 category:\u003c\/strong\u003e Transducers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e Temperature signal transducer \/ conditioner - analog output - WAGO (JUMPFLEX series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85437090300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-21-01-29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-21-01-29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002919\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002919\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143655507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e bag\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.2 … 2.5 mm² \/ 24 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.2 … 2.5 mm² \/ 24 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 9 … 10 mm \/ 0.35 … 0.39 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWAGO connector:\u003c\/strong\u003e \u003ci\u003epicoMAX\u003c\/i\u003e\u003csup\u003e®\u003c\/sup\u003e 5.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|75980-60-8|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide|Perfluorobutane sulfonic acid (PFBS) and its salts|Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e beac9352-aef0-42a2-b7f0-a83392390cff\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e eeb9df68-9e28-4e3e-92ac-8ef9ab87c305\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e 61e19286-b116-40e0-90e0-0d98747b35c6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e ccfdefc9-f0b3-4620-b412-b6adce9425b4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 1d7e7fd7-5fa4-47bb-96ed-30ae8a6161f6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 4e130f44-9148-4325-97d7-6d58f5d97835\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e 30e01dd3-5b6f-498f-9b37-54a0502b9f9e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e ef2b2ca0-d8d7-4e0c-81db-287ee7497471\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e 93a905b5-7155-4b52-8695-61a9c5ddcc08\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 7a1074e6-72fb-4fec-bfaa-c1cebf85968f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e e6753189-be82-47d8-93e5-8cabc3e2d142\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 91684334-ada5-46cb-8352-31567b986a40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 9a8786ac-ee1e-477b-8851-a03a87e77e4a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e b9aa1443-ef24-4f0e-a0f8-b04a5d1a7f4f\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -40 … +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 2000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 95 % (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable:\u003c\/strong\u003e ≥ (T\u003csub\u003eambient\u003c\/sub\u003e + 10 K)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range of connection cable (UL):\u003c\/strong\u003e 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 2.158MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 126.9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e This product is supplied with 24 VDC, which can be commoned using lateral push-in type jumper bars: (6.1) U\u003csub\u003eS\u003c\/sub\u003e+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 1 A is not exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 107 mm \/ 4.213 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 110 mm \/ 4.331 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 22.5 mm \/ 0.886 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination (UL) - Insulation type (input\/analog output\/relay output\/supply):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination (UL) - Insulation type (input\/DIN-rail contact\/relay output\/supply):\u003c\/strong\u003e Reinforced insulation (safe isolation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination (UL) - Overvoltage category:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation coordination (UL) - Pollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement category per EN\/UL 61010-2-030:\u003c\/strong\u003e CAT II (input)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on insulation parameters:\u003c\/strong\u003e The digital output (DO) is at the potential of the supply. The service interface is located on the analog output potential. The DIN-rail contact (functional ground) is capacitively coupled to the analog output.|The digital output (DO) is at the potential of the supply.|The service interface is located on the analog output potential.|The DIN-rail contact (functional ground) is capacitively coupled to the analog output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage of the measurement circuit connections per EN 61010-2-030:\u003c\/strong\u003e AC 300 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage (input\/analog output\/relay output\/supply):\u003c\/strong\u003e 3 kVAC; 50 … 60 Hz; 1 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage (input\/DIN-rail contact\/relay output\/supply):\u003c\/strong\u003e 3 kVAC; 50 … 60 Hz; 1 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest voltage - Test voltage (input\/output\/supply):\u003c\/strong\u003e 3 kVAC; 50 Hz; 1 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission of interference:\u003c\/strong\u003e EN 61000-6-3; EN 61326-2-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity to interference:\u003c\/strong\u003e EN 61000-6-2; EN 61326-2-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e EN 61010-1|EN 61373|EN 61010-1|EN 61373\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration - Configuration options:\u003c\/strong\u003e WAGO Configuration Display|WAGO Interface Configuration Software|WAGO Interface Configuration App|WAGO Configuration Display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input signal type:\u003c\/strong\u003e RTD sensors|Potentiometer|Resistance|TC sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (resistors) - Input range (potentiometer):\u003c\/strong\u003e 0 … 10 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (resistors) - Input range (resistor):\u003c\/strong\u003e 0 … 10 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (resistors) - Measurement span (min.):\u003c\/strong\u003e 50Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Measurement span (RTD) min.:\u003c\/strong\u003e 50K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Sensor connection:\u003c\/strong\u003e 2-wire; 3-wire; 4-wire; differential; potentiometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Sensor power supply (RTD) max.:\u003c\/strong\u003e ≤ 0.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Sensor types (RTD):\u003c\/strong\u003e Pt10 … Pt2000 (expandable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (RTD sensors) - Temperature measurement range (RTD):\u003c\/strong\u003e -200 … +850 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (TC sensors) - Cold junction compensation:\u003c\/strong\u003e ON\/OFF (default: ON)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (TC sensors) - Cold junction error:\u003c\/strong\u003e 3 K (typ. 2 K )\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (TC sensors) - Measurement span (TC) min.:\u003c\/strong\u003e 100K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (TC sensors) - Sensor types (TC):\u003c\/strong\u003e Type J|Type K|Type E|Type R|Type N|Type S|Type T|Type B|Type C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput (TC sensors) - Temperature measurement range (TC):\u003c\/strong\u003e -200 … 1200 °C (Type J)|-200 … 1372 °C (Type K)|-200 … 1000 °C (Type E)|250 … 1768 °C (Type R)|-200 … 1300 °C (Type N)|-50 … 1664 °C (Type S)|-200 … 400 °C (Type T)|250 … 1820 °C (Type B)|0 … 2320 °C (Type C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Temperature coefficient:\u003c\/strong\u003e ≤ 0.01 %\/K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error (typ.):\u003c\/strong\u003e ≤ 0.1 % at full measurement span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error - Transmission error for the set measurement range:\u003c\/strong\u003e ≤ (100 K\/set measurement range [K]) %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Load impedance (current output):\u003c\/strong\u003e ≤ 600 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Load impedance (voltage output):\u003c\/strong\u003e ≥ 2 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal (current):\u003c\/strong\u003e ±24 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal (voltage):\u003c\/strong\u003e ±12 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (analog) - Output signal type:\u003c\/strong\u003e Current|Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Configurable rise\/fall delay time (DO):\u003c\/strong\u003e 0 … 60 s (via software)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Continuous current (DO) max.:\u003c\/strong\u003e 100 mA (no internal restriction)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Number of switching thresholds (DO):\u003c\/strong\u003e 1 or 2 (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (digital) - Switching voltage (DO) max.:\u003c\/strong\u003e Supply voltage (applied) - 0.3 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Configurable rise\/fall delay time (relay):\u003c\/strong\u003e 0 … 60 s (via software)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Dielectric strength (open contact) (AC, 1 min):\u003c\/strong\u003e 1kV\u003csub\u003erms\u003c\/sub\u003e|1 kVrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Number of changeover\/switchover contacts:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Number of switching thresholds (relay):\u003c\/strong\u003e 1 or 2 (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput (relay) - Switching Voltage, Max.:\u003c\/strong\u003e 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Current consumption at nominal supply voltage:\u003c\/strong\u003e ≤ 70 mA (+ I\u003csub\u003eDO\u003c\/sub\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Nominal supply voltage U\u003csub\u003eS\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Power supply type:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply - Supply voltage range:\u003c\/strong\u003e -60 … +30 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Software filter (adjustable):\u003c\/strong\u003e Moving average value (filter level: 30)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing - Step response (typ.):\u003c\/strong\u003e 130 ms (2-wire)|700 ms (3-wire)|700 ms (4-wire)|600 ms (differential)|500 ms (potentiometer)|150 ms (cold junction compensation Off)|400 ms (cold junction compensation On)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47696224157833,"sku":"60348333","price":654.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/2000-8120132-de_48ea3944-3fff-4bb1-9813-2bffdd27e9a3.jpg?v=1786992177","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2857-536","provider":"US Automation Controls","version":"1.0","type":"link"}