Wago - 285-134
$13.33
Sale price
$13.33
Regular price
Neutral-through terminal block with 1-deck/level + side/lateral marking slots - WAGO (285 series) - Blue - Neutral-through pole (N) / 2-wires (1 clamp + 1 clamp) (1+1) - 35mm2 nominal cross-section - for 6mm2...35mm2 / for #8AWG...#2AWG - Rated current 125A - with POWER CAGE-CLAMP screw connections - DIN-35 rail (35 x 15) mounting (16mm width) - equivalent to 285134
Specifications
- Primary brand: WAGO
- Functions: Neutral-through terminal block
- Design: 1-deck/level|side/lateral marking slots|side/lateral wire entry|2 jumper slots
- Poles: Neutral-through pole (N)
- Temperature: Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C
- Rated current: (IEC) 125A|(UL) 115A|(CSA) 115A
- Color: Blue
- Connection capacity: 2-wires (1 clamp + 1 clamp) (1+1)
- Rated operating voltage (Ue): (IEC) 1000V|(UL) 600V|(CSA) 600V
- Rated impulse voltage (Uimp): (IEC) 8kV
- Connection type: POWER CAGE-CLAMP screw connections
- Cross-section: for 6mm2...35mm2 fine stranded or solid conductors|for 6mm2...35mm2 fine stranded conductors with insulated ferrule|for #8AWG...#2AWG fine stranded or solid conductors|for #8AWG...#2AWG fine stranded conductors with insulated ferrule|35mm2 nominal cross-section
- Mounting mode: DIN-35 rail (35 x 15)
- Dimensions: H86mm x W16mm x D63mm
- Net Width (mm): 16mm
- Material: Polyamide (PA) 66
- ETIM code: EC000897
- GTIN code: 4045454507398
- Customs Tariff Number: 85369010000
- eClass code: 27-14-11-20
- Order code / Manufacturer SKU: 285-134
- Manufacturer product status: Commercialized
- Equivalent to: 285134
- EAN code: 4045454507398
- Compliant with standard(s): General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL-7707|- CSA - DEKRA Certification B.V. - C22.2 No. 158 - certificate 154112|- KEMA/KEUR - DEKRA Certification B.V. - EN 60947 - certificate 71-105562|- UL - Underwriters Laboratories Inc. - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- Railway - WAGO GmbH & Co. KG - certificate Z00004420.000|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- ABS - American Bureau of Shipping - EN 60947 - certificate 20-HG1941090-PDA|- DNV GL - Det Norske Veritas Germanischer Lloyd - certificate TAE00001V2|- LR - Lloyds Register - EN 60947 - certificate 91/20112 (E9)|RoHS compliant|material group I|V-0 flammability rating
- Location of origin: Poland
- Level 1 category: Electrical components
- Level 2 category: Terminal blocks
- Product title: Neutral-through terminal block - 1-deck/level - WAGO
Commercial data
- Country of origin: PL
- Customs tariff number: 85369010000
- ECCN: NO US CLASSIFICATION
- eCl@ss 10.0: 27-14-11-20
- eCl@ss 9.0: 27-14-11-20
- ETIM 8.0: EC000897
- ETIM 9.0: EC000897
- GTIN: 4045454507398
- Packaging type: box
- Product Group: 1 (Rail Mounted Terminal Blocks)
- PU (SPU): 15 pcs
Connection data
- Clamping units: 2
- Connection 1 - Actuation type: Operating tool
- Connection 1 - Connectable conductor materials: Copper
- Connection 1 - Connection technology: POWER CAGE CLAMP
- Connection 1 - Fine-stranded conductor: 6 … 35 mm² / 8 … 2 AWG
- Connection 1 - Fine-stranded conductor; with insulated ferrule: 6 … 35 mm² / 8 … 2 AWG
- Connection 1 - Fine-stranded conductor; with uninsulated ferrule: 6 … 35 mm² / 8 … 2 AWG
- Connection 1 - Nominal cross-section: 35 mm²
- Connection 1 - Solid conductor: 6 … 35 mm² / 8 … 2 AWG
- Connection 1 - Stranded conductor: 6 … 35 mm² / 8 … 2 AWG
- Connection 1 - Strip length: 25 mm / 0.98 inches
- Connection 1 - Wiring direction: Side-entry wiring
- Number of jumper slots: 2
- Number of levels: 1
- Total number of potentials: 1
Electrical data
- Power Loss - Power loss, per pole (potential): 4.062W
- Power Loss - Rated current IN for specified power loss: 125A
- Power Loss - Resistance value for specified, current-dependent power loss: 0Ω
- Ratings per CSA - Approvals per: CSA 22.2 No 158
- Ratings per CSA - Rated current CSA (Use Group B): 115A
- Ratings per CSA - Rated current CSA (Use Group D): 115A
- Ratings per CSA - Rated voltage CSA (Use Group B): 600V
- Ratings per CSA - Rated voltage CSA (Use Group C): 600V
- Ratings per IEC/EN - Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
- Ratings per IEC/EN - Nominal voltage (III/3): 1000V
- Ratings per IEC/EN - Rated current: 125A
- Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 8kV
- Ratings per IEC/EN - Ratings per: IEC/EN 60947-7-1
- Ratings per UL - Approvals per: UL 1059
- Ratings per UL - Rated current UL (Use Group B): 115A
- Ratings per UL - Rated current UL (Use Group C): 115A
- Ratings per UL - Rated voltage UL (Use Group B): 600V
- Ratings per UL - Rated voltage UL (Use Group C): 600V
Environmental Product Compliance
- RoHS Compliance Status: Compliant,No Exemption
Environmental requirements
- Continuous operating temperature: -60 … +105 °C
- Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
- Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
- Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
- Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
- Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
- Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
- Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
- Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
- Environmental Testing (Environmental Conditions) - Shock form: Half sine
- Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
- Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
- Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
- Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
- Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
-
Environmental Testing (Environmental Conditions) - Test procedure
Railway applications –
Rolling stock equipment –
Shock and vibration tests: DIN EN 61373 (VDE 0115-0106):2011-04 -
Environmental Testing (Environmental Conditions) - Test specification
Railway applications –
Rolling stock –
Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06 - Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
- Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
- Processing temperature: -35 … +85 °C
Material data
- Color: blue
- Fire load: 1.252MJ
- Flammability class per UL94: V0
- Insulation material (main housing): Polyamide (PA66)
- Material group: I
-
Note (material data):
Information on material specifications can be found here
- Weight: 79.3g
Mechanical data
- Marking level: Side marking
- Mounting (note): only suitable for DIN 35 x 15 rail
- Mounting type: DIN-rail 35 x 15
Physical data
- Depth from upper-edge of DIN-rail: 63 mm / 2.48 inches
- Height: 86 mm / 3.386 inches
- Width: 16 mm / 0.63 inches