{"product_id":"wago-2687-2145","title":"Wago - 2687-2144","description":"\u003cp\u003eAC-to-DC Eco2 switch-mode power supply unit (SMPS PSU) with DC-OK rly. contact output - WAGO (Power supply units Eco 2 series) - 24Vdc (SELV) \/ 5A \/ 120W output - Input voltage 90-264Vac (110Vac \/ 120Vac \/ 220Vac \/ 230Vac \/ 240Vac) (Single-phase AC (1AC)) - with Push-in CAGE CLAMP spring connections - DIN-35 rail mounting (38mm width) - IP20 - rated for -25°C...+70°C ambient - equivalent to 26872144\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork frequency:\u003c\/strong\u003e 50-60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e AC-to-DC Eco2 switch-mode power supply unit (SMPS PSU)|Series operation possible|Parallel operation possible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e DC-OK rly. contact output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage (AC):\u003c\/strong\u003e 90-264Vac (110Vac \/ 120Vac \/ 220Vac \/ 230Vac \/ 240Vac)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED status indication (DC OK; Overload)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of network:\u003c\/strong\u003e Single-phase AC (1AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 5A (-25...+55°C)|3.125A (70°C; -2.5% output derating for every 1K temperature rise above 55°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated power:\u003c\/strong\u003e 120W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage (DC):\u003c\/strong\u003e 24Vdc (SELV)|23-28Vdc (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHold time:\u003c\/strong\u003e 20ms (230Vac input)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Push-in CAGE CLAMP spring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection functions:\u003c\/strong\u003e T 3.15A \/ 250Vac internal fuse|Constant power (up to 125%)|Shutdown and automatic restart in the event of a short circuit|Short-circuit protection|Open circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 0.9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting mode:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement accuracy:\u003c\/strong\u003e ≤ 1% (output error)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e H130mm x W38mm x D130mm|H5.118\" x W1.496\" x D5.118\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Width (mm):\u003c\/strong\u003e 38mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for operation:\u003c\/strong\u003e -25°C...+70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient air temperature for storage:\u003c\/strong\u003e -40°C...+85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-96% relative humidity (RH; non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 0.8A (230Vac; Nominal load)|1.5A (100Vac; Nominal load)|20A inrush (after 1 ms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85044083900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM code:\u003c\/strong\u003e EC002540\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4066966401080\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2687-2144\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 26872144\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4066966207439\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s):\u003c\/strong\u003e Safety and protection|- Overvoltage category -- III (≤ 2000m a.s.l.); II (\u0026gt; 2000m a.s.l.)|- Isolation voltage (pri.-sec.; AC) -- 3510V|- Isolation voltage (pri.-PE; AC) -- 2200V|- Isolation voltage (sec.-PE; DC) -- 0.5kVDC|CE|EN 61010-1|EN 61010-2-201|EN 61204-3|SEMI F47|UL 61010-1|UL 61010-2-201|General approvals|- EAC - GZO Almaty Standart - TP TC 004\/2011 - certificate EAC CoC 03080|- EAC - GZO Almaty Standart - TP TC 020\/2011 - certificate EAC CoC 03081|- UL - Underwriters Laboratories Inc. - UL 61010-2-201 - certificate UL-US-2218925-0_UL-CA-2218432-0|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|- MFD for SEMI F47 - WAGO GmbH \u0026amp; Co. KG|- UK-Declaration of Conformity - WAGO GmbH \u0026amp; Co. KG|Approvals for hazardous areas|- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726|RoHS compliant with exemption (6(c) \/ 7(a) \/ 7(c)-I \/ 7(c)-II)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of pollution:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple:\u003c\/strong\u003e 75mVpp (output voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF (Mean Time Between Failures):\u003c\/strong\u003e 1 100 000h (as per IEC 61709)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Signal output‚ optical status indication|Suitable for both parallel and series operation|Natural convection cooling when horizontally mounted|Connection technology with push-in termination and tool-free lever operation|Electrically isolated output voltage (SELV\/PELV) per EN 61010\/UL 61010|Marker slot for WAGO marking cards (WMB) and WAGO marking strips\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Automation components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 2 category:\u003c\/strong\u003e Power supply units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct title:\u003c\/strong\u003e AC-to-DC Eco2 switch-mode power supply unit (SMPS PSU) - WAGO (Eco 2 series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85044083900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002540\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002540\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4066966401080\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e Box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 1 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type 1:\u003c\/strong\u003e Input\/output\/signaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-stranded conductor:\u003c\/strong\u003e 0.2 … 4 mm² \/ 24 … 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid conductor:\u003c\/strong\u003e 0.2 … 4 mm² \/ 24 … 12 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAS-No.:\u003c\/strong\u003e 1303-86-2|1317-36-8|7439-92-1|79-94-7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Candidate List Substance:\u003c\/strong\u003e 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol|Diboron trioxide|Lead|Lead monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,With Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Exemption:\u003c\/strong\u003e 6(c)|7(a)|7(c)-I|7(c)-II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Austria):\u003c\/strong\u003e 88b095ec-76a2-44ba-bc4f-8af04d3aa869\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Belgium):\u003c\/strong\u003e 1f36d4b5-c2bd-4fa4-9ba7-fab4560274ea\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Bulgaria):\u003c\/strong\u003e ece2741c-94c2-4643-8455-4af30ed67835\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Czech Republic):\u003c\/strong\u003e cd95343d-b393-43cf-80b0-cccb5257bbfd\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Denmark):\u003c\/strong\u003e 8de2a84b-c12a-4761-91dd-b119773534c8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Finland):\u003c\/strong\u003e 37dca7ef-68a8-4237-96ee-ffc69fca1b79\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (France):\u003c\/strong\u003e be625ff9-61f8-44cb-a1b4-9c91e7ab498f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Germany):\u003c\/strong\u003e 0f1a79bc-42ce-497c-93aa-169b84dec80a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Hungary):\u003c\/strong\u003e c75d9660-e9e0-4f6a-8094-a02f7eb002c5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Italy):\u003c\/strong\u003e 4058ebcb-e5d3-4e13-8a2c-bb034a513773\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Netherlands):\u003c\/strong\u003e e09550f1-21a2-4612-b815-cd116bb56de2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Poland):\u003c\/strong\u003e 42928b5b-13e1-44dc-bfe4-9af43f5d13b6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Romania):\u003c\/strong\u003e 42dd0d9d-70ff-4898-aa20-05f92774b9fb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP notification number (Sweden):\u003c\/strong\u003e d048877f-4660-48fa-8533-a6cfed8010d2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation):\u003c\/strong\u003e -25 … +70 °C (Device starts at -40 °C (type-tested))\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage):\u003c\/strong\u003e -40 … +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimatic category:\u003c\/strong\u003e 3K3 (per EN 60721)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDerating:\u003c\/strong\u003e -2.5 %\/K, \u0026gt; 55 °C; -10 %\/V, \u0026gt; 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude (max.):\u003c\/strong\u003e 5000m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 … 96 % (no condensation permissible)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 620g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting type:\u003c\/strong\u003e DIN-35 rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth from upper-edge of DIN-rail:\u003c\/strong\u003e 130 mm \/ 5.118 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 130 mm \/ 5.118 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 38 mm \/ 1.496 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage (pri.-PE, AC):\u003c\/strong\u003e 2,200V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage (pri.-sec., AC):\u003c\/strong\u003e 3,510V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage (sec.-PE):\u003c\/strong\u003e 0.5 kVDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage (sec.-signal):\u003c\/strong\u003e 0.5 kVDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e \u0026gt; 1,000,000 h (per IEC 61709)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-circuit-proof:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e III (≤ 2000 m a.s.l.); II (\u0026gt; 2000 m a.s.l.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel operation:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection class:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection type:\u003c\/strong\u003e IP20; per EN 60529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries operation:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit-protected:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards and specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity marking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/specifications:\u003c\/strong\u003e SEMI F47|EN 61010-1|EN 61010-2-201|EN 61204-3|UL 61010-1|UL 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection - Backup fusing (recommended):\u003c\/strong\u003e 16 A (for USA\/Canada: 15 A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection - Internal fuse:\u003c\/strong\u003e T 3.15 A \/ 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\/power losses - Efficiency (typ.):\u003c\/strong\u003e 90 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\/power losses - Power loss P\u003csub\u003el\u003c\/sub\u003e:\u003c\/strong\u003e ≤ 3 W; ≤ 12 W (nominal load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input current I\u003csub\u003ei\u003c\/sub\u003e:\u003c\/strong\u003e ≤ 0.8 A (230 VAC; nominal load); ≤ 1.5 A (100 VAC; nominal load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Input voltage range:\u003c\/strong\u003e 1 x 90 … 264 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Inrush current:\u003c\/strong\u003e ≤ 20 A (after 1 ms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Mains failure hold-up time:\u003c\/strong\u003e ≥ 20 ms (230 VAC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Nominal input voltage U\u003csub\u003ei nom\u003c\/sub\u003e:\u003c\/strong\u003e 1 x 100 … 240 VAC|1 x AC 100 … 240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Nominal mains frequency range:\u003c\/strong\u003e 50 … 60 Hz; 0 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Phases:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput - Power factor correction (PFC):\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Default setting:\u003c\/strong\u003e DC 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Deviation:\u003c\/strong\u003e ≤ 1 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Nominal output current I\u003csub\u003eo nom\u003c\/sub\u003e:\u003c\/strong\u003e 5 A (24 VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Nominal output power:\u003c\/strong\u003e 120W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Nominal output voltage U\u003csub\u003eo nom\u003c\/sub\u003e:\u003c\/strong\u003e 24 VDC (SELV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Output voltage range:\u003c\/strong\u003e 23 … 28 VDC (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Overload behavior:\u003c\/strong\u003e Constant power up to 125 %; shutdown and automatic restart in the event of a short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput - Residual ripple:\u003c\/strong\u003e ≤ 75 mV (peak-to-peak)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignaling and communication - Signaling:\u003c\/strong\u003e Optical status indication (overload)|Optical status indication (DC OK)|Digital signal output (DO)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695321170057,"sku":"60531476","price":123.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/1706\/2281\/files\/2000-9025325-de_4edfa0cf-32f1-4664-b793-6082260768d0.jpg?v=1786987550","url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2687-2145","provider":"US Automation Controls","version":"1.0","type":"link"}