{"product_id":"wago-2606-1104","title":"Wago - 2606-1101","description":"\u003cp\u003eWAGO component - equivalent to 26061101\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143586405\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2606-1101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 26061101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143586405\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e PCB terminal block; lever; 6mm2; Pin spacing 7.5mm; 1-pole; Push-in CAGE CLAMP; 6mm2; gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Poland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- The inherent stability of a single-pole PCB terminal block is less than that of a multi-pole terminal strip. The customer must therefore ensure that these terminal blocks are protected against excessive mechanical stress (e.g.; torsional or bending stress); both when connecting the conductor and during subsequent use; for example by providing additional support; shortly holding the connected conductor and appropriate actuation instructions.|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 1000V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 8kV|Electrical data - Ratings per IEC\/EN - Rated voltage (III\/2) -- 1000V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III\/2) -- 8kV|Electrical data - Ratings per IEC\/EN - Nominal voltage (II\/2) -- 1000V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (II\/2) -- 8kV|Electrical data - Ratings per IEC\/EN - Rated current -- 41A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 2) Overvoltage category III \/ Pollution degree 2|Electrical data - Ratings per UL - Approvals per -- UL 1059|Electrical data - Ratings per UL - Rated voltage UL (Use Group B) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group B) -- 31A|Electrical data - Ratings per UL - Rated voltage UL (Use Group C) -- 600V|Electrical data - Ratings per UL - Rated current UL (Use Group C) -- 31A|Electrical data - Ratings per CSA - Approvals per -- CSA|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group B) -- 600V|Electrical data - Ratings per CSA - Rated current CSA (Use Group B) -- 31A|Electrical data - Ratings per CSA - Rated voltage CSA (Use Group C) -- 1000V|Electrical data - Ratings per CSA - Rated current CSA (Use Group C) -- 31A|Connection data - Clamping units -- 1|Connection data - Total number of potentials -- 1|Connection data - Number of connection types -- 1|Connection data - Number of levels -- 1|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Lever|Connection data - Connection 1 - Solid conductor -- 0.2...10mm2 \/ 24...8 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.2...10mm2 \/ 24...8 AWG|Connection data - Connection 1 - Fine-stranded conductor; with insulated ferrule -- 0.25...6mm2|Connection data - Connection 1 - Fine-stranded conductor; with uninsulated ferrule -- 0.25...6mm2|Connection data - Connection 1 - Fine-stranded conductor; with twin ferrule -- 0.25...2.5mm2|Connection data - Connection 1 - Strip length -- 11...13mm \/ 0.43...0.51\"|Connection data - Connection 1 - Conductor connection direction to PCB -- 0°|Connection data - Connection 1 - Pole number -- 1|Physical data - Pin spacing -- 7.5mm \/ 0.295\"|Physical data - Width -- 10.35mm \/ 0.407\"|Physical data - Height -- 28mm \/ 1.102\"|Physical data - Height from the surface -- 24mm \/ 0.945\"|Physical data - Depth -- 24.3mm \/ 0.957\"|Physical data - Solder pin length -- 4mm|Physical data - Solder pin dimensions -- 1.5 x 1.2mm|Physical data - Drilled hole diameter with tolerance -- 2 \u003csup\u003e(+0.1)\u003c\/sup\u003emm|PCB contact - PCB contact -- THT|PCB contact - Solder pin arrangement -- Over the entire terminal strip (in-line)|PCB contact - Number of solder pins per potential -- 2|Material data - Color -- gray|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyamide (PA66)|Material data - Flammability class per UL94 -- V0|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Electrolytic Copper (E\u003csub\u003eCu\u003c\/sub\u003e)|Material data - Contact plating -- Tin|Material data - Fire load -- 0.101MJ|Material data - Actuator color -- orange|Material data - Weight -- 4.5g|Environmental requirements - Limit temperature range -- -60...+105°C|Environmental requirements - Processing temperature -- -35...+60°C|Environmental requirements - Continuous operating temperature -- -60...+105°C|Environmental requirements - Environmental Testing (Environmental Conditions) - Test specification \/ Railway applications - \/ Rolling stock - \/ Electronic equipment -- DIN EN 50155 (VDE 0115-200)2022-06|Environmental requirements - Environmental Testing (Environmental Conditions) - Test procedure \/ Railway applications - \/ Rolling stock equipment - \/ Shock and vibration tests -- DIN EN 61373 (VDE 0115-0106)2011-04|Environmental requirements - Environmental Testing (Environmental Conditions) - Spectrum\/Installation location -- Service life test; Category 1; Class A\/B|Environmental requirements - Environmental Testing (Environmental Conditions) - Function test with noise-like vibration -- Test passed according to Section 8 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Frequency -- f\u003csub\u003e1 \u003c\/sub\u003e= 5Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150Hz|Environmental requirements - Environmental Testing (Environmental Conditions) - Acceleration -- 0.101g (highest test level used for all axes) \/ 0.572g (highest test level used for all axes) \/ 5g (highest test level used for all axes)|Environmental requirements - Environmental Testing (Environmental Conditions) - Test duration per axis -- 10 min. \/ 5 h|Environmental requirements - Environmental Testing (Environmental Conditions) - Test directions -- X; Y and Z axes|Environmental requirements - Environmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration -- Test passed according to Section 9 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock test -- Test passed according to Section 10 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock form -- Half sine|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock duration -- 30ms|Environmental requirements - Environmental Testing (Environmental Conditions) - Number of shocks per axis -- 3 pos. und 3 neg.|Environmental requirements - Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment -- Passed|Commercial data - eClass 10.0 -- 27-44-04-01|Commercial data - eClass 9.0 -- 27-44-04-01|Commercial data - ETIM 9.0 -- EC002643|Commercial data - ETIM 8.0 -- EC002643|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 200 pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- PL|Commercial data - GTIN -- 4055143586405|Commercial data - Customs tariff number -- 85369010000|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e PL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85369010000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-44-04-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-44-04-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC002643\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC002643\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143586405\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 200 pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor connection direction to PCB:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.2 … 10 mm² \/ 24 … 8 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with insulated ferrule:\u003c\/strong\u003e 0.25 … 6 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with twin ferrule:\u003c\/strong\u003e 0.25 … 2.5 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor; with uninsulated ferrule:\u003c\/strong\u003e 0.25 … 6 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.2 … 10 mm² \/ 24 … 8 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 11 … 13 mm \/ 0.43 … 0.51 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of connection types:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Approvals per:\u003c\/strong\u003e CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group B):\u003c\/strong\u003e 31A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated current CSA (Use Group C):\u003c\/strong\u003e 31A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group B):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per CSA - Rated voltage CSA (Use Group C):\u003c\/strong\u003e 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 2) ≙ Overvoltage category III \/ Pollution degree 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (II\/2):\u003c\/strong\u003e 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 41A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (II\/2):\u003c\/strong\u003e 8kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 8kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III\/2):\u003c\/strong\u003e 8kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated voltage (III\/2):\u003c\/strong\u003e 1000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Approvals per:\u003c\/strong\u003e UL 1059\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group B):\u003c\/strong\u003e 31A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated current UL (Use Group C):\u003c\/strong\u003e 31A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group B):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL - Rated voltage UL (Use Group C):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous operating temperature:\u003c\/strong\u003e -60 … +105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Acceleration:\u003c\/strong\u003e 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Frequency:\u003c\/strong\u003e f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz|f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Function test with noise-like vibration:\u003c\/strong\u003e Test passed according to Section 8 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Number of shocks per axis:\u003c\/strong\u003e 3 pos. und 3 neg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock duration:\u003c\/strong\u003e 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock form:\u003c\/strong\u003e Half sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock test:\u003c\/strong\u003e Test passed according to Section 10 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration:\u003c\/strong\u003e Test passed according to Section 9 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Spectrum\/Installation location:\u003c\/strong\u003e Service life test, Category 1, Class A\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test directions:\u003c\/strong\u003e X, Y and Z axes|X, Y and Z axes|X, Y and Z axes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test duration per axis:\u003c\/strong\u003e 10 min.|5 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test procedure \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock equipment – \u003cbr\u003eShock and vibration tests:\u003c\/strong\u003e DIN EN 61373 (VDE 0115-0106):2011-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test specification \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock – \u003cbr\u003eElectronic equipment:\u003c\/strong\u003e DIN EN 50155 (VDE 0115-200):2022-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit temperature range:\u003c\/strong\u003e -60 … +105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing temperature:\u003c\/strong\u003e -35 … +60 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator color:\u003c\/strong\u003e orange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e gray\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Electrolytic copper (E\u003csub\u003eCu\u003c\/sub\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.101MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyamide (PA66)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.5g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The inherent stability of a single-pole PCB terminal block is less than that of a multi-pole terminal strip. The customer must therefore ensure that these terminal blocks are protected against excessive mechanical stress (e.g., torsional or bending stress), both when connecting the conductor and during subsequent use, for example by providing additional support, shortly holding the connected conductor and appropriate actuation instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariants::\u003c\/strong\u003e Other pole numbers|Direct marking|Other colors|Other versions (or variants) can be requested from WAGO Sales or configured at https:\/\/configurator.wago.com\/.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePCB contact\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of solder pins per potential:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB contact:\u003c\/strong\u003e THT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin arrangement:\u003c\/strong\u003e Over the entire terminal strip (in-line)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 24.3 mm \/ 0.957 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrilled hole diameter with tolerance:\u003c\/strong\u003e 2 \u003csup\u003e(+0.1)\u003c\/sup\u003e mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 28 mm \/ 1.102 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight from the surface:\u003c\/strong\u003e 24 mm \/ 0.945 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 7.5 mm \/ 0.295 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin dimensions:\u003c\/strong\u003e 1.5 x 1.2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin length:\u003c\/strong\u003e 4mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 10.35 mm \/ 0.407 inches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47696155213961,"sku":"60331700","price":2.13,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2606-1104","provider":"US Automation Controls","version":"1.0","type":"link"}