{"product_id":"wago-2065-100-998-404","title":"Wago - 2065-100\/998-403","description":"\u003cp\u003eWAGO component - equivalent to 2065100998403\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143665469\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2065-100\/998-403\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 2065100998403\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143665469\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e SMD PCB terminal block; push-button; 0.75mm2; Pin spacing 6.5mm; 1-pole; Push-in CAGE CLAMP; in tape-and-reel packaging; Without housing; 0.75mm2; Silver-colored\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Safety Information -- Notice Terminal block without insulation housing! Protection against accidental contact must be provided at voltages higher than low voltages (e.g.; SELV\/PELV) for the relevant application.|Notes - Note -- The ratings are based on an example pin spacing of 6.5mm. \/ The layout must meet the requirements of the insulation coordination standard EN\/IEC 60664-1 and applicable end product standards.|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Rated voltage (III\/2) -- 320V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III\/2) -- 4kV|Electrical data - Ratings per IEC\/EN - Nominal voltage (II\/2) -- 630V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (II\/2) -- 4kV|Electrical data - Ratings per IEC\/EN - Rated current -- 9A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 2) Overvoltage category III \/ Pollution degree 2|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 600V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 9A|Connection data - Clamping units -- 1|Connection data - Total number of potentials -- 1|Connection data - Number of connection types -- 1|Connection data - Number of levels -- 1|Connection data - Connection 1 - Connection technology -- Push-in CAGE CLAMP|Connection data - Connection 1 - Actuation type -- Push-button|Connection data - Connection 1 - Solid conductor -- 0.2...0.75mm2 \/ 24...18 AWG|Connection data - Connection 1 - Fine-stranded conductor -- 0.2...0.75mm2 \/ 24...18 AWG|Connection data - Connection 1 - Strip length -- 7.5...9.5mm \/ 0.3...0.37\"|Connection data - Connection 1 - Conductor connection direction to PCB -- 0°|Connection data - Connection 1 - Pole number -- 1|Physical data - Pin spacing -- 6.5mm \/ 0.256\"|Physical data - Width -- 2.9mm \/ 0.114\"|Physical data - Height -- 2.7mm \/ 0.106\"|Physical data - Depth -- 8mm \/ 0.315\"|Physical data - Reel diameter of tape-and-reel packaging -- 330mm|Physical data - Tape width -- 16mm|PCB contact - PCB contact -- SMD|PCB contact - Solder pin arrangement -- Over the entire terminal strip (in-line)|PCB contact - Number of solder pins per potential -- 1|Material data - Color -- Silver-colored|Material data - Clamping spring material -- Chrome-Nickel spring steel (CrNi)|Material data - Contact material -- Copper alloy|Material data - Contact plating -- Tin|Material data - Weight -- 0.1g|Environmental requirements - Limit temperature range -- -60...+120°C|Environmental requirements - Environmental Testing (Environmental Conditions) - Test specification \/ Railway applications - \/ Rolling stock - \/ Electronic equipment -- DIN EN 50155 (VDE 0115-200)2022-06|Environmental requirements - Environmental Testing (Environmental Conditions) - Test procedure \/ Railway applications - \/ Rolling stock equipment - \/ Shock and vibration tests -- DIN EN 61373 (VDE 0115-0106)2011-04|Environmental requirements - Environmental Testing (Environmental Conditions) - Spectrum\/Installation location -- Service life test; Category 1; Class A\/B|Environmental requirements - Environmental Testing (Environmental Conditions) - Function test with noise-like vibration -- Test passed according to Section 8 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Frequency -- f\u003csub\u003e1 \u003c\/sub\u003e= 5Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150Hz|Environmental requirements - Environmental Testing (Environmental Conditions) - Acceleration -- 0.101g (highest test level used for all axes) \/ 0.572g (highest test level used for all axes) \/ 5g (highest test level used for all axes)|Environmental requirements - Environmental Testing (Environmental Conditions) - Test duration per axis -- 10 min. \/ 5 h|Environmental requirements - Environmental Testing (Environmental Conditions) - Test directions -- X; Y and Z axes|Environmental requirements - Environmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration -- Test passed according to Section 9 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock test -- Test passed according to Section 10 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock form -- Half sine|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock duration -- 30ms|Environmental requirements - Environmental Testing (Environmental Conditions) - Number of shocks per axis -- 3 pos. und 3 neg.|Environmental requirements - Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment -- Passed|Commercial data - eClass 10.0 -- 27-14-11-06|Commercial data - eClass 9.0 -- 27-14-11-06|Commercial data - ETIM 9.0 -- EC001284|Commercial data - ETIM 8.0 -- EC001284|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 31800 (2650) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- CH|Commercial data - GTIN -- 4055143665469|Commercial data - Customs tariff number -- 85369010000|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Switzerland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e CH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85369010000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-14-11-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-14-11-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001284\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001284\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143665469\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 31800 (2650) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Push-button\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor connection direction to PCB:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e Push-in CAGE CLAMP\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Fine-stranded conductor:\u003c\/strong\u003e 0.2 … 0.75 mm² \/ 24 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.2 … 0.75 mm² \/ 24 … 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 7.5 … 9.5 mm \/ 0.3 … 0.37 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of connection types:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 2) ≙ Overvoltage category III \/ Pollution degree 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (II\/2):\u003c\/strong\u003e 630V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 9A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (II\/2):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III\/2):\u003c\/strong\u003e 4kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated voltage (III\/2):\u003c\/strong\u003e 320V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 9A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Acceleration:\u003c\/strong\u003e 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Frequency:\u003c\/strong\u003e f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz|f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Function test with noise-like vibration:\u003c\/strong\u003e Test passed according to Section 8 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Number of shocks per axis:\u003c\/strong\u003e 3 pos. und 3 neg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock duration:\u003c\/strong\u003e 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock form:\u003c\/strong\u003e Half sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock test:\u003c\/strong\u003e Test passed according to Section 10 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration:\u003c\/strong\u003e Test passed according to Section 9 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Spectrum\/Installation location:\u003c\/strong\u003e Service life test, Category 1, Class A\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test directions:\u003c\/strong\u003e X, Y and Z axes|X, Y and Z axes|X, Y and Z axes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test duration per axis:\u003c\/strong\u003e 10 min.|5 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test procedure \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock equipment – \u003cbr\u003eShock and vibration tests:\u003c\/strong\u003e DIN EN 61373 (VDE 0115-0106):2011-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test specification \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock – \u003cbr\u003eElectronic equipment:\u003c\/strong\u003e DIN EN 50155 (VDE 0115-200):2022-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit temperature range:\u003c\/strong\u003e -60 … +120 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping spring material:\u003c\/strong\u003e Chrome-nickel spring steel (CrNi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e silver-colored\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.1g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The ratings are based on an example pin spacing of 6.5 mm.\u003cbr\u003eThe layout must meet the requirements of the insulation coordination standard EN\/IEC 60664-1 and applicable end product standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Information:\u003c\/strong\u003e \u003cp\u003e\u003cb\u003eNotice:\u003c\/b\u003e \u003cb\u003eTerminal block without insulation housing! Protection against accidental contact must be provided at voltages higher than low voltages (e.g., SELV\/PELV) for the relevant application.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePCB contact\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of solder pins per potential:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB contact:\u003c\/strong\u003e SMD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin arrangement:\u003c\/strong\u003e Over the entire terminal strip (in-line)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 8 mm \/ 0.315 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 2.7 mm \/ 0.106 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 6.5 mm \/ 0.256 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReel diameter of tape-and-reel packaging:\u003c\/strong\u003e 330mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTape width:\u003c\/strong\u003e 16mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 2.9 mm \/ 0.114 inches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695152873609,"sku":"60350724","price":0.33,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2065-100-998-404","provider":"US Automation Controls","version":"1.0","type":"link"}