{"product_id":"wago-2059-302-998-404","title":"Wago - 2059-302\/998-403","description":"\u003cp\u003eWAGO component - equivalent to 2059302998403\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary brand:\u003c\/strong\u003e WAGO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN code:\u003c\/strong\u003e 4055143082686\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU:\u003c\/strong\u003e 2059-302\/998-403\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product status:\u003c\/strong\u003e Commercialized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent to:\u003c\/strong\u003e 2059302998403\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN code:\u003c\/strong\u003e 4055143082686\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e SMD PCB terminal block; 0.5mm2; Pin spacing 3mm; 2-pole; PUSH WIRE; in tape-and-reel packaging; 0.5mm2; white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer product specifications:\u003c\/strong\u003e Notes - Note -- Application notes Suitable for Lead-free; reflow-soldering profiles per DIN EN 61760-1 and IEC 60068-2-58 up to max. 260°C peak temperature. Due to application-specific variables (component configuration and orientation; type of soldering machine; solder paste); trial runs are recommended to ensure product and process compatibility under actual manufacturing conditions. \/ Depending on reflow soldering temperatures and times; color deviations may occur. These deviations will have no impact on functionality.|Notes - Recommendation -- Recommendation for stencil 150μm material thickness; Pattern layout identical to solder pad layout|Electrical data - Ratings per IEC\/EN - Ratings per -- IEC\/EN 60664-1|Electrical data - Ratings per IEC\/EN - Nominal voltage (III\/3) -- 63V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III \/ 3) -- 2.5kV|Electrical data - Ratings per IEC\/EN - Rated voltage (III\/2) -- 160V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (III\/2) -- 2.5kV|Electrical data - Ratings per IEC\/EN - Nominal voltage (II\/2) -- 320V|Electrical data - Ratings per IEC\/EN - Rated impulse withstand voltage (II\/2) -- 2.5kV|Electrical data - Ratings per IEC\/EN - Rated current -- 3A|Electrical data - Ratings per IEC\/EN - Legend (ratings) -- (III \/ 2) Overvoltage category III \/ Pollution degree 2|Electrical data - Ratings per UL 1977 - Rated voltage (UL 1977) -- 250V|Electrical data - Ratings per UL 1977 - Rated current UL 1977 -- 3A|Connection data - Clamping units -- 2|Connection data - Total number of potentials -- 2|Connection data - Number of connection types -- 1|Connection data - Number of levels -- 1|Connection data - Connection 1 - Connection technology -- PUSH WIRE|Connection data - Connection 1 - Actuation type -- Operating tool|Connection data - Connection 1 - Solid conductor -- 0.14...0.34mm2 \/ 26...22 AWG|Connection data - Connection 1 - Note (conductor cross-section) -- For conductors (26 AWG) that are not rigid enough; the clamping unit must be opened using an operating tool.|Connection data - Connection 1 - Strip length -- 4...5.5mm \/ 0.16...0.22\"|Connection data - Connection 1 - Conductor connection direction to PCB -- 0°|Connection data - Connection 1 - Pole number -- 2|Connection data - Connection 2 - Solid conductor -- 0.5mm2 \/ 20 AWG|Connection data - Connection 2 - Note (conductor cross-section) -- No reconnection of smaller conductor cross-sections (0.5mm2\/20 AWG)|Connection data - Connection 2 - Strip length -- 6...7.5mm \/ 0.24...0.3\"|Physical data - Pin spacing -- 3mm \/ 0.118\"|Physical data - Width -- 5.9mm \/ 0.232\"|Physical data - Height -- 2.7mm \/ 0.106\"|Physical data - Depth -- 7.9mm \/ 0.311\"|Physical data - Reel diameter of tape-and-reel packaging -- 330mm|Physical data - Tape width -- 16mm|PCB contact - PCB contact -- SMD|PCB contact - Solder pin arrangement -- Over the entire terminal strip (in-line)|PCB contact - Number of solder pins per potential -- 2|Material data - Color -- white|Material data - Material group -- I|Material data - Insulation material (main housing) -- Polyphthalamide (PPA GF)|Material data - Flammability class per UL94 -- V0|Material data - Contact material -- Copper alloy|Material data - Contact plating -- Tin|Material data - Fire load -- 0.002MJ|Material data - Weight -- 0.2g|Environmental requirements - Limit temperature range -- -60...+105°C|Environmental requirements - Environmental Testing (Environmental Conditions) - Test specification \/ Railway applications - \/ Rolling stock - \/ Electronic equipment -- DIN EN 50155 (VDE 0115-200)2022-06|Environmental requirements - Environmental Testing (Environmental Conditions) - Test procedure \/ Railway applications - \/ Rolling stock equipment - \/ Shock and vibration tests -- DIN EN 61373 (VDE 0115-0106)2011-04|Environmental requirements - Environmental Testing (Environmental Conditions) - Spectrum\/Installation location -- Service life test; Category 1; Class A\/B|Environmental requirements - Environmental Testing (Environmental Conditions) - Function test with noise-like vibration -- Test passed according to Section 8 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Frequency -- f\u003csub\u003e1 \u003c\/sub\u003e= 5Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150Hz|Environmental requirements - Environmental Testing (Environmental Conditions) - Acceleration -- 0.101g (highest test level used for all axes) \/ 0.572g (highest test level used for all axes) \/ 5g (highest test level used for all axes)|Environmental requirements - Environmental Testing (Environmental Conditions) - Test duration per axis -- 10 min. \/ 5 h|Environmental requirements - Environmental Testing (Environmental Conditions) - Test directions -- X; Y and Z axes|Environmental requirements - Environmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration -- Test passed according to Section 9 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Monitoring for contact faults\/interruptions -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Extended test scope Voltage drop measurement before and after each axis -- Passed|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock test -- Test passed according to Section 10 of the standard|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock form -- Half sine|Environmental requirements - Environmental Testing (Environmental Conditions) - Shock duration -- 30ms|Environmental requirements - Environmental Testing (Environmental Conditions) - Number of shocks per axis -- 3 pos. und 3 neg.|Environmental requirements - Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment -- Passed|Commercial data - Product Group -- 33 (SMT Terminal)|Commercial data - eClass 10.0 -- 27-14-11-06|Commercial data - eClass 9.0 -- 27-14-11-06|Commercial data - ETIM 9.0 -- EC001284|Commercial data - ETIM 8.0 -- EC001284|Commercial data - ECCN -- NO US CLASSIFICATION|Commercial data - PU (SPU) -- 21000 (1750) pcs|Commercial data - Packaging type -- box|Commercial data - Country of origin -- CH|Commercial data - GTIN -- 4055143082686|Commercial data - Customs tariff number -- 85369010000|Environmental Product Compliance - RoHS Compliance Status -- Compliant;No Exemption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation of origin:\u003c\/strong\u003e Switzerland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel 1 category:\u003c\/strong\u003e Electrical components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e CH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms tariff number:\u003c\/strong\u003e 85369010000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e NO US CLASSIFICATION\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 10.0:\u003c\/strong\u003e 27-14-11-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeCl@ss 9.0:\u003c\/strong\u003e 27-14-11-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 8.0:\u003c\/strong\u003e EC001284\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9.0:\u003c\/strong\u003e EC001284\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 4055143082686\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging type:\u003c\/strong\u003e box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e 33 (SMT Terminal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePU (SPU):\u003c\/strong\u003e 21000 (1750) pcs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnection data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping units:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Actuation type:\u003c\/strong\u003e Operating tool\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Conductor connection direction to PCB:\u003c\/strong\u003e 0°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Connection technology:\u003c\/strong\u003e PUSH WIRE\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Note (conductor cross-section):\u003c\/strong\u003e For conductors (26 AWG) that are not rigid enough, the clamping unit must be opened using an operating tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Pole number:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Solid conductor:\u003c\/strong\u003e 0.14 … 0.34 mm² \/ 26 … 22 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 1 - Strip length:\u003c\/strong\u003e 4 … 5.5 mm \/ 0.16 … 0.22 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 2 - Note (conductor cross-section):\u003c\/strong\u003e No reconnection of smaller conductor cross-sections (0.5 mm²\/20 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 2 - Solid conductor:\u003c\/strong\u003e 0.5 mm² \/ 20 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection 2 - Strip length:\u003c\/strong\u003e 6 … 7.5 mm \/ 0.24 … 0.3 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of connection types:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of levels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal number of potentials:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Legend (ratings):\u003c\/strong\u003e (III \/ 2) ≙ Overvoltage category III \/ Pollution degree 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (II\/2):\u003c\/strong\u003e 320V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Nominal voltage (III\/3):\u003c\/strong\u003e 63V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated current:\u003c\/strong\u003e 3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (II\/2):\u003c\/strong\u003e 2.5kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III \/ 3):\u003c\/strong\u003e 2.5kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated impulse withstand voltage (III\/2):\u003c\/strong\u003e 2.5kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Rated voltage (III\/2):\u003c\/strong\u003e 160V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per IEC\/EN - Ratings per:\u003c\/strong\u003e IEC\/EN 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated current UL 1977:\u003c\/strong\u003e 3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings per UL 1977 - Rated voltage (UL 1977):\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Product Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status:\u003c\/strong\u003e Compliant,No Exemption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Acceleration:\u003c\/strong\u003e 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed|Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Frequency:\u003c\/strong\u003e f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz|f\u003csub\u003e1 \u003c\/sub\u003e= 5 Hz to f\u003csub\u003e2 \u003c\/sub\u003e= 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Function test with noise-like vibration:\u003c\/strong\u003e Test passed according to Section 8 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Monitoring for contact faults\/interruptions:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Number of shocks per axis:\u003c\/strong\u003e 3 pos. und 3 neg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock duration:\u003c\/strong\u003e 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock form:\u003c\/strong\u003e Half sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Shock test:\u003c\/strong\u003e Test passed according to Section 10 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration:\u003c\/strong\u003e Test passed according to Section 9 of the standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Spectrum\/Installation location:\u003c\/strong\u003e Service life test, Category 1, Class A\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test directions:\u003c\/strong\u003e X, Y and Z axes|X, Y and Z axes|X, Y and Z axes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test duration per axis:\u003c\/strong\u003e 10 min.|5 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test procedure \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock equipment – \u003cbr\u003eShock and vibration tests:\u003c\/strong\u003e DIN EN 61373 (VDE 0115-0106):2011-04\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Test specification \u003cbr\u003eRailway applications – \u003cbr\u003eRolling stock – \u003cbr\u003eElectronic equipment:\u003c\/strong\u003e DIN EN 50155 (VDE 0115-200):2022-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis:\u003c\/strong\u003e Passed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit temperature range:\u003c\/strong\u003e -60 … +105 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e white\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Copper alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact plating:\u003c\/strong\u003e Tin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire load:\u003c\/strong\u003e 0.002MJ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability class per UL94:\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation material (main housing):\u003c\/strong\u003e Polyphthalamide (PPA GF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial group:\u003c\/strong\u003e I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote (material data):\u003c\/strong\u003e \u003cbr\u003e\t\t\t\t\t\t\u003ca href=\"https:\/\/www.wago.com\/us\/material-specifications\" target=\"_blank\"\u003eInformation on material specifications can be found here\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cp\u003eApplication notes:\u003c\/p\u003e\n\u003cp\u003eSuitable for lead-free, reflow-soldering profiles per DIN EN 61760-1 and IEC 60068-2-58 up to max. 260°C peak temperature. Due to application-specific variables (component configuration and orientation, type of soldering machine, solder paste), trial runs are recommended to ensure product and process compatibility under actual manufacturing conditions.\u003c\/p\u003e|\u003cp\u003eDepending on reflow soldering temperatures and times, color deviations may occur. These deviations will have no impact on functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommendation:\u003c\/strong\u003e \u003cp\u003eRecommendation for stencil:\u003c\/p\u003e\n\u003cp\u003e150 µm material thickness; Pattern layout identical to solder pad layout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePCB contact\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of solder pins per potential:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB contact:\u003c\/strong\u003e SMD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolder pin arrangement:\u003c\/strong\u003e Over the entire terminal strip (in-line)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 7.9 mm \/ 0.311 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 2.7 mm \/ 0.106 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin spacing:\u003c\/strong\u003e 3 mm \/ 0.118 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReel diameter of tape-and-reel packaging:\u003c\/strong\u003e 330mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTape width:\u003c\/strong\u003e 16mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 5.9 mm \/ 0.232 inches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":47695577645193,"sku":"51300196","price":0.58,"currency_code":"USD","in_stock":true}],"url":"https:\/\/primitive-lemur-2993c0.myshopify.com\/products\/wago-2059-302-998-404","provider":"US Automation Controls","version":"1.0","type":"link"}