Test plug adapter - WAGO (2009 TOPJOB S series) - 1-pole (1P) - Rated current 10A - Gray color (10.15mm width) - compatible with 4mm test plug - equivalent to 2009174

Specifications

  • Primary brand: WAGO
  • Functions: Test plug adapter
  • Poles: 1-pole (1P)
  • Rated current: 10A
  • Color: Gray
  • Dimensions: H48.6mm x W10.15mm x D7.2mm
  • Net Width (mm): 10.15mm
  • Technical compatibility with: 4mm test plug
  • Customs Tariff Number: 85366990990
  • GTIN code: 4017332074988
  • eClass code: 27-14-11-48
  • ETIM code: EC002555
  • Order code / Manufacturer SKU: 2009-174
  • Manufacturer product status: Commercialized
  • Equivalent to: 2009174
  • EAN code: 4017332074988
  • Compliant with standard(s): Declarations of conformity and manufacturer's declarations|- Railway - WAGO GmbH & Co. KG - certificate Railway Ready|RoHS compliant with exemption (6(c))
  • Location of origin: Germany
  • Level 1 category: Cabling systems
  • Level 2 category: Connectors & Inserts
  • Product title: Test plug adapter - WAGO (TOPJOB S series)

Commercial data

  • Country of origin: DE
  • Customs tariff number: 85366990990
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-48
  • eCl@ss 9.0: 27-14-11-48
  • ETIM 8.0: EC002555
  • ETIM 9.0: EC002555
  • GTIN: 4017332074988
  • Packaging type: box
  • Product Group: 2 (Terminal Block Accessories)
  • PU (SPU): 100 (25) pcs

Electrical data

  • Ratings per IEC/EN - Rated current: 10A

Environmental Product Compliance

  • CAS-No.: 7439-92-1
  • REACH Candidate List Substance: Lead
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)
  • SCIP notification number (Austria): 1bfe9d8d-c4e0-4a6d-83c7-cf06dc9eadad
  • SCIP notification number (Belgium): a3edd670-1365-4ee8-a93b-d1a159ff4e85
  • SCIP notification number (Bulgaria): 7a1dfd17-054a-4a77-9814-bfeaddfaffbd
  • SCIP notification number (Czech Republic): f6ba8076-4b3e-4554-bada-9257290cdabb
  • SCIP notification number (Denmark): cdfc2ba4-20f3-4859-95b5-95ce6982cad9
  • SCIP notification number (Finland): 8f57db27-6d24-4acd-9ffe-bbe0235eb83c
  • SCIP notification number (France): d051844b-e912-4d8f-b1de-970af13d61b5
  • SCIP notification number (Germany): aedda25b-65bf-4057-99e2-5773fe464019
  • SCIP notification number (Hungary): fb448482-0d52-42b7-b903-113f4c0590ec
  • SCIP notification number (Italy): 41463d2b-01cc-487a-b815-be66de537a8a
  • SCIP notification number (Netherlands): ffd6a813-8826-402e-ae0c-0ecc31f5d6ca
  • SCIP notification number (Poland): b375c51f-dfab-45af-9b76-2fe6547e2f46
  • SCIP notification number (Romania): bb60bde0-4755-4d68-bed3-89a3817c43e8
  • SCIP notification number (Sweden): d1d53a18-fac1-4eec-b726-d8e185c6abed

Environmental requirements

  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed

Material data

Notes

  • Safety Information: Power must be switched off when installing the test plug adapter. The safety guidelines for working on live installations must be observed.

Physical data

  • Depth: 7.2 mm / 0.283 inches
  • Height: 48.6 mm / 1.913 inches
  • Width: 10.15 mm / 0.4 inches