Feed-through/thru disconnect/test terminal block with 1-deck/level + lever disconnect + connector for adjacent jumper + side/lateral and center marking slots - WAGO (2007 TOPJOB S series) - Gray - 1 disconnect feed-through pole (1P) / 2-wires (1 push-in + 1 push-in) (1+1) - 6mm2 nominal cross-section - for 0.5mm2...10mm2 / for #20AWG...#8AWG - Rated current 30A - with Push-in CAGE CLAMP spring connections - DIN-35 rail (35 x 15 / 35 x 7.5) mounting (8mm width) - equivalent to 20078821

Specifications

  • Primary brand: WAGO
  • Functions: Feed-through/thru disconnect/test terminal block
  • Design: 1-deck/level|lever disconnect|connector for adjacent jumper|side/lateral and center marking slots|2 jumper slots
  • Poles: 1 disconnect feed-through pole (1P)
  • Temperature: Processing temperature -35°C...+85°C|Continuous operating temperature -60°C...+105°C
  • Rated current: (IEC) 30A|(UL) 30A|(CSA) 30A
  • Color: Gray
  • Connection capacity: 2-wires (1 push-in + 1 push-in) (1+1)
  • Rated operating voltage (Ue): (IEC) 500V|(UL) 300V|(CSA) 300V
  • Rated impulse voltage (Uimp): (IEC) 6kV
  • Connection type: Push-in CAGE CLAMP spring connections
  • Cross-section: for 0.5mm2...10mm2 fine stranded or solid conductors|for 0.5mm2...6mm2 fine stranded conductors with insulated ferrule|for 2.5mm2...6mm2 fine stranded conductors with ferrule; push-in termination|for 1mm2...10mm2 solid conductors; push-in termination|for #20AWG...#8AWG fine stranded or solid conductors|for #20AWG...#10AWG fine stranded conductors with insulated ferrule|for #16AWG...#10AWG fine stranded conductors with ferrule; push-in termination|for #14AWG...#8AWG solid conductors; push-in termination|6mm2 nominal cross-section
  • Mounting mode: DIN-35 rail (35 x 15 / 35 x 7.5)
  • Dimensions: H99.6mm x W8mm x D65.3mm
  • Net Width (mm): 8mm
  • Material: Polyamide (PA) 66
  • GTIN code: 4055143074889
  • ETIM code: EC000902
  • Customs Tariff Number: 85365080000
  • eClass code: 27-14-11-26
  • Order code / Manufacturer SKU: 2007-8821
  • Manufacturer product status: Commercialized
  • Equivalent to: 20078821
  • EAN code: 4055143074889
  • Compliant with standard(s): General approvals|- CCA - DEKRA Certification B.V. - EN 60947 - certificate 71-122099|- CCA - DEKRA Certification B.V. - EN 60947 - certificate NTR NL 7911|- CSA - DEKRA Certification B.V. - C22.2 No. 158 - certificate 70009679|- UL - UL International Germany GmbH - UL 1059 - certificate E45172|Declarations of conformity and manufacturer's declarations|- EU-Declaration of Conformity - WAGO GmbH & Co. KG|- Railway - WAGO GmbH & Co. KG - certificate Railway Ready|- UK-Declaration of Conformity - WAGO GmbH & Co. KG|Approvals for marine applications|- DNV GL - Det Norske Veritas Germanischer Lloyd - certificate TAE00001V2|RoHS compliant with exemption (6(c))|material group I|V-0 flammability rating
  • Location of origin: China
  • Level 1 category: Electrical components
  • Level 2 category: Terminal blocks
  • Product title: Feed-through/thru disconnect/test terminal block - 1-deck/level - WAGO (TOPJOB S series)

Commercial data

  • Country of origin: CN
  • Customs tariff number: 85365080000
  • ECCN: NO US CLASSIFICATION
  • eCl@ss 10.0: 27-14-11-26
  • eCl@ss 9.0: 27-14-11-26
  • ETIM 8.0: EC000902
  • ETIM 9.0: EC000902
  • GTIN: 4055143074889
  • Packaging type: box
  • Product Group: 22 (TOPJOB S)
  • PU (SPU): 20 pcs

Connection data

  • Clamping units: 2
  • Connection 1 - Actuation type: Operating tool
  • Connection 1 - Connectable conductor materials: Copper
  • Connection 1 - Connection technology: Push-in CAGE CLAMP®
  • Connection 1 - Fine-stranded conductor: 0.5 … 10 mm² / 20 … 8 AWG
  • Connection 1 - Fine-stranded conductor; with ferrule; push-in termination: 2.5 … 6 mm² / 16 … 10 AWG
  • Connection 1 - Fine-stranded conductor; with insulated ferrule: 0.5 … 6 mm² / 20 … 10 AWG
  • Connection 1 - Fine-stranded conductor; with uninsulated ferrule: 1.5 … 6 mm² / 16 … 10 AWG
  • Connection 1 - Nominal cross-section: 6 mm² / 10 AWG
  • Connection 1 - Solid conductor: 0.5 … 10 mm² / 20 … 8 AWG
  • Connection 1 - Solid conductor; push-in termination: 1 … 10 mm² / 14 … 8 AWG
  • Connection 1 - Strip length: 13 … 15 mm / 0.51 … 0.59 inches
  • Connection 1 - Wiring direction: Front-entry wiring
  • Number of jumper slots: 2
  • Number of levels: 1
  • Total number of potentials: 2

Electrical data

  • Power Loss - Power loss, per pole (potential): 0.702W
  • Power Loss - Rated current IN for specified power loss: 30A
  • Power Loss - Resistance value for specified, current-dependent power loss: 0.001Ω
  • Ratings per CSA - Approvals per: CSA 22.2 No 158
  • Ratings per CSA - Rated current CSA (Use Group B): 30A
  • Ratings per CSA - Rated current CSA (Use Group C): 30A
  • Ratings per CSA - Rated current CSA (Use Group D): 10A
  • Ratings per CSA - Rated voltage CSA (Use Group B): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group C): 300V
  • Ratings per CSA - Rated voltage CSA (Use Group D): 300V
  • Ratings per IEC/EN - Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • Ratings per IEC/EN - Nominal voltage (III/3): 500V
  • Ratings per IEC/EN - Rated current: 30A
  • Ratings per IEC/EN - Rated impulse withstand voltage (III / 3): 6kV
  • Ratings per IEC/EN - Ratings per: IEC/EN 60664-1
  • Ratings per UL - Approvals per: UL 1059
  • Ratings per UL - Rated current UL (Use Group B): 30A
  • Ratings per UL - Rated current UL (Use Group C): 30A
  • Ratings per UL - Rated current UL (Use Group D): 10A
  • Ratings per UL - Rated voltage UL (Use Group B): 300V
  • Ratings per UL - Rated voltage UL (Use Group C): 300V
  • Ratings per UL - Rated voltage UL (Use Group D): 300V

Environmental Product Compliance

  • CAS-No.: 7439-92-1
  • REACH Candidate List Substance: Lead
  • RoHS Compliance Status: Compliant,With Exemption
  • RoHS Exemption: 6(c)
  • SCIP notification number (Austria): 1e2c4f68-0c80-4f7f-b4d2-ef9b6ed3f735
  • SCIP notification number (Belgium): 1a46df3e-2ff6-4cf3-a263-340ef76fa1f1
  • SCIP notification number (Bulgaria): 72f5ce78-1f67-471a-94a3-5898375f14ad
  • SCIP notification number (Czech Republic): ad5734e3-cdb1-429e-8734-a0ee4cd49658
  • SCIP notification number (Denmark): b401e4ad-1620-4947-b7de-3f25977d8bb1
  • SCIP notification number (Finland): 579c56ae-46b0-4b84-942e-7623c8338835
  • SCIP notification number (France): a4ec1bfd-c70f-4a69-b65f-bdebdedcbd5b
  • SCIP notification number (Germany): c074da76-1734-4521-a06a-664455df075b
  • SCIP notification number (Hungary): 7c7aea40-b04a-49a6-9b36-bb658cda7ee1
  • SCIP notification number (Italy): 97ddee9e-6f84-4304-abef-21c95eabb33d
  • SCIP notification number (Netherlands): 3d7fc2ee-5b30-4782-8d24-56b6e1c59f55
  • SCIP notification number (Poland): 57bafb00-40d2-41d5-9b04-7c3ca60febb1
  • SCIP notification number (Romania): 201ddf09-009d-457f-aa41-ec1c2f19a211
  • SCIP notification number (Sweden): b67a192b-2617-4193-a205-27932d31da00

Environmental requirements

  • Continuous operating temperature: -60 … +105 °C
  • Environmental Testing (Environmental Conditions) - Acceleration: 0.101g (highest test level used for all axes)|0.572g (highest test level used for all axes)|5g (highest test level used for all axes)
  • Environmental Testing (Environmental Conditions) - Extended test scope: Monitoring for contact faults/interruptions: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Extended test scope: Voltage drop measurement before and after each axis: Passed|Passed
  • Environmental Testing (Environmental Conditions) - Frequency: f1 = 5 Hz to f2 = 150 Hz|f1 = 5 Hz to f2 = 150 Hz
  • Environmental Testing (Environmental Conditions) - Function test with noise-like vibration: Test passed according to Section 8 of the standard
  • Environmental Testing (Environmental Conditions) - Monitoring for contact faults/interruptions: Passed
  • Environmental Testing (Environmental Conditions) - Number of shocks per axis: 3 pos. und 3 neg.
  • Environmental Testing (Environmental Conditions) - Shock duration: 30 ms
  • Environmental Testing (Environmental Conditions) - Shock form: Half sine
  • Environmental Testing (Environmental Conditions) - Shock test: Test passed according to Section 10 of the standard
  • Environmental Testing (Environmental Conditions) - Simulated service life test through increased levels of noise-like vibration: Test passed according to Section 9 of the standard
  • Environmental Testing (Environmental Conditions) - Spectrum/Installation location: Service life test, Category 1, Class A/B
  • Environmental Testing (Environmental Conditions) - Test directions: X, Y and Z axes|X, Y and Z axes|X, Y and Z axes
  • Environmental Testing (Environmental Conditions) - Test duration per axis: 10 min.|5 h
  • Environmental Testing (Environmental Conditions) - Test procedure
    Railway applications –
    Rolling stock equipment –
    Shock and vibration tests:
    DIN EN 61373 (VDE 0115-0106):2011-04
  • Environmental Testing (Environmental Conditions) - Test specification
    Railway applications –
    Rolling stock –
    Electronic equipment:
    DIN EN 50155 (VDE 0115-200):2022-06
  • Environmental Testing (Environmental Conditions) - Vibration and shock stress for rolling stock equipment: Passed
  • Environmental Testing (Environmental Conditions) - Voltage drop measurement before and after each axis: Passed
  • Processing temperature: -35 … +85 °C

Material data

Mechanical data

  • Marking level: Center/side marking
  • Mounting type: DIN-35 rail

Physical data

  • Depth from upper-edge of DIN-rail: 65.3 mm / 2.571 inches
  • Height: 99.6 mm / 3.921 inches
  • Width: 8 mm / 0.315 inches